Validation of the soft-embalmed Thiel cadaver as a high-fidelity simulator of pressure during targeted nerve injection

被引:10
作者
McLeod, Graeme [1 ,2 ]
Zihang, Shengli [2 ]
Sadler, Amy [3 ]
Chandra, Anu [2 ]
Qiao, Panpan [4 ]
Huang, Zhihong [2 ]
Demore, Christine [5 ]
机构
[1] Ninewells Hosp, Dept Anaesthesia, Dundee DD1 9SY, Scotland
[2] Univ Dundee, Inst Acad Anaesthesia, Dundee, Scotland
[3] Ninewells Hosp & Med Sch, Dept Anaesthesia, Dundee, Scotland
[4] Univ Dundee, Dept Bioengn, Dundee, Scotland
[5] Sunnybrook Res Inst, Dept Biophys, Toronto, ON, Canada
关键词
INTRANEURAL INJECTION; REGIONAL ANESTHESIA; PERINEURAL INJECTIONS; NEUROLOGIC DEFICITS; DELIBERATE PRACTICE; EXPERT-PERFORMANCE; NEEDLE-NERVE; ULTRASOUND; ACQUISITION; INJURY;
D O I
10.1136/rapm-2020-102132
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Introduction Although administration of regional anesthesia nerve blocks has increased during the COVID-19 pandemic, training opportunities in regional anesthesia have reduced. Simulation training may enhance skills, but simulators must be accurate enough for trainees to engage in a realistic way-for example, detection of excessive injection pressure. The soft-embalmed Thiel cadaver is a life-like, durable simulator that is used for dedicated practice and mastery learning training in regional anesthesia. We hypothesized that injection opening pressure in perineural tissue, at epineurium and in subepineurium were similar to opening pressures measured in experimental animals, fresh frozen cadavers, glycol soft-fix cadavers and patients. Methods We systematically reviewed historical data, then conducted three validation studies delivering a 0.5 mL hydrolocation bolus of embalming fluid and recording injection pressure. First, we delivered the bolus at 12 mL/min at epimysium, perineural tissue, epineurium and in subepineurium at 48 peripheral nerve sites on three cadavers. Second, we delivered the bolus at using three infusion rates: 1 mL/min, 6 mL/min and 12 mL/ min on epineurium at 70 peripheral nerve sites on five cadavers. Third, we repeated three injections (12 mL/min) at 24 epineural sites over the median and sciatic nerves of three cadavers. Results Mean (95%) injection pressure was greater at epineurium compared with subepineurium (geometric ratio 1.2 (95% CI: 0.9 to 1.6)), p=0.04, and perineural tissue (geometric ratio 5.1 (95% CI: 3.7 to 7.0)), p<0.0001. Mean (95%) injection pressure was greater at 12 mL/min compared with 1 mL/min (geometric ratio 1.6 (95% CI: 1.2 to 2.1), p=0.005). Pressure measurements were similar in study 3 (p>0.05 for all comparisons). Discussion We conclude that the soft-embalmed Thiel cadaver is a realistic simulator of injection opening pressure.
引用
收藏
页码:540 / 548
页数:9
相关论文
共 34 条
[1]   Deliberate practice using validated metrics improves skill acquisition in performance of ultrasound-guided peripheral nerve block in a simulated setting [J].
Ahmed, Osman M. A. ;
Azher, Imran ;
Gallagher, Anthony G. ;
Breslin, Dara S. ;
O'Donnell, Brian D. ;
Shorten, George D. .
JOURNAL OF CLINICAL ANESTHESIA, 2018, 48 :22-27
[2]   Ultrasonographic Appearance of Intraneural Injections in the Porcine Model [J].
Altermatt, Fernando R. ;
Cummings, Thomas J. ;
Auten, Kathryn M. ;
Baldwin, Mathew F. ;
Belknap, Samuel W. ;
Reynolds, James D. .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2010, 35 (02) :203-206
[3]   The nuts and bolts of PROSPERO: An international prospective register of systematic reviews [J].
Alison Booth ;
Mike Clarke ;
Gordon Dooley ;
Davina Ghersi ;
David Moher ;
Mark Petticrew ;
Lesley Stewart .
Systematic Reviews, 1 (1)
[4]   Identifying the needle-tip position during regional anaesthesia with needle-tip pressure at different flow rates [J].
Chandra, A. ;
Yan, J. ;
Soenjaya, Y. ;
Demore, C. ;
Columb, M. ;
McLeod, G. .
BRITISH JOURNAL OF ANAESTHESIA, 2018, 121 (02) :E30-E31
[5]   The feasibility of micro-ultrasound as a tool to image peripheral nerves [J].
Chandra, A. ;
Eisma, R. ;
Felts, P. ;
Munirama, S. ;
Corner, G. A. ;
Demore, C. E. M. ;
McLeod, G. .
ANAESTHESIA, 2017, 72 (02) :190-196
[6]  
Chandra A, 2018, IEEE INT ULTRA SYM
[7]   A randomised controlled trial comparing meat-based with human cadaveric models for teaching ultrasound-guided regional anaesthesia [J].
Chuan, A. ;
Lim, Y. C. ;
Aneja, H. ;
Duce, N. A. ;
Appleyard, R. ;
Forrest, K. ;
Royse, C. F. .
ANAESTHESIA, 2016, 71 (08) :921-929
[8]   Education and training in ultrasound-guided regional anaesthesia and pain medicine [J].
Chuan, Alwin .
CURRENT OPINION IN ANESTHESIOLOGY, 2020, 33 (05) :674-684
[9]   From "Silent Teachers" to Models [J].
Eisma, Roos ;
Wilkinson, Tracey .
PLOS BIOLOGY, 2014, 12 (10)
[10]   Liver displacement during ventilation in Thiel embalmed human cadavers - a possible model for research and training in minimally invasive therapies [J].
Eisma, Roos ;
Gueorguieva, Mariana ;
Immel, Erwin ;
Toomey, Rachel ;
McLeod, Graeme ;
Soames, Roger ;
Melzer, Andreas .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2013, 22 (05) :291-296