Comparison of Dimensions of the Nasopharynx and Oropharynx Using Different Anatomical References: Is There Equivalence?

被引:5
作者
de Torres, Hianne Miranda [1 ,2 ]
Evangelista, Karine [1 ]
de Torres, Erica Miranda [3 ]
Estrela, Carlos [1 ]
de Souza Figueiredo, Paulo Tadeu [4 ]
Valladares-Neto, Jose [5 ]
Garcia Silva, Maria Alves [1 ]
机构
[1] Univ Fed Goias, Dept Oral Sci, Sch Dent, Ave Univ Esquina Com 1a Ave S-N,Setor Univ, BR-74605220 Goiania, Go, Brazil
[2] Fac Sul Amer, Sch Dent, Goiania, Go, Brazil
[3] Univ Fed Goias, Dept Oral Rehabil, Sch Dent, Goiania, Go, Brazil
[4] Univ Brasilia, Dept Oral Radiol, Brasilia, DF, Brazil
[5] Univ Fed Goias, Div Orthodont, Sch Dent, Goiania, Go, Brazil
关键词
BEAM COMPUTED-TOMOGRAPHY; UPPER AIRWAY; PHARYNGEAL AIRWAY; RELIABILITY; VOLUME; SPACE;
D O I
10.1016/j.joms.2019.07.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the equivalence of the volumes obtained using different anatomic references to measure the nasopharynx and oropharynx on cone-beam computed tomography (CBCT) scans. We hypothesized that no variations would be found in the nasopharynx and oropharynx dimensions when measured using different measurement method. Materials and Methods: A total of 40 CBCT scans of patients with skeletal Class I (age range, 20 to 50 years) were measured independently by 2 of us. The nasopharynx and oropharynx subregions were volumetrically measured using the adopted limits of 5 different measurement methods (3 for the nasopharynx and 2 for the oropharynx) and InVivoDental software, version 5.4 (Anatomage, San Jose, CA). The minimum area and the minimum area of localization were also evaluated. The intra- and interexaminer concordance for the measurements from the different methods were verified using the interclass correlation coefficient (ICC). The analysis of variance for repeated measures was used to compare the measurements from the 3 nasopharynx methods. The paired t test was used to compare the measurements from the 2 oropharynx methods. The statistical tests were performed at the 5% significance level using SPSS software, version 22.0 (IBM Corp, Armonk, NY). Results: The intra- and interexaminer ICC values were greater than 0.8. We found a statistically significant difference in the volume measurements among the 3 nasopharynx methods (P=.001). However, no differences were found in the minimum area or minimum area of localization comparisons. Statistically significant differences were also observed for the volume, minimum area, and minimum area of localization between the 2 oropharynx methods (P=.001). Conclusions: Studies that have used different methods of measurement should not be directly compared. The different measurement methods used for nasopharynx and oropharynx evaluations should not be compared. (C) 2019 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:2545 / 2554
页数:10
相关论文
共 26 条
[1]  
Aboudara C A, 2003, Orthod Craniofac Res, V6 Suppl 1, P173, DOI 10.1034/j.1600-0544.2003.253.x
[2]   Comparison of airway space with conventional lateral headfilms and 3-dimensional reconstruction from cone-beam computed tomography [J].
Aboudara, Cameron ;
Nielsen, Ib ;
Huang, John C. ;
Maki, Koutaro ;
Miller, Arthur J. ;
Hatcher, David .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (04) :468-479
[3]   Three-dimensional assessment of pharyngeal airway in nasal- and mouth-breathing children [J].
Alves, Matheus, Jr. ;
Baratieri, Carolina ;
Nojima, Lincoln I. ;
Nojima, Matilde C. G. ;
Ruellas, Antonio C. O. .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2011, 75 (09) :1195-1199
[4]   Proposal of new upper airway margins in children assessed by CBCT [J].
Anandarajah, S. ;
Abdalla, Y. ;
Dudhia, R. ;
Sonnesen, L. .
DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (07)
[5]   Volumetric upper airway changes after rapid maxillary expansion: a systematic review and meta-analysis [J].
Buck, Lloyd M. ;
Dalci, Oyku ;
Darendeliler, M. Ali ;
Papageorgiou, Spyridon N. ;
Papadopoulou, Alexandra K. .
EUROPEAN JOURNAL OF ORTHODONTICS, 2017, 39 (05) :463-473
[6]   Reliability of three-dimensional measurements of the upper airway on cone beam computed tomography images [J].
Chen, Hui ;
Aarab, Ghizlane ;
Parsa, Azin ;
de Lange, Jan ;
van der Stelt, Paul F. ;
Lobbezoo, Frank .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 122 (01) :104-110
[7]   A new simple three-dimensional method to characterize upper airway in orthognathic surgery patient [J].
Di Carlo, Gabriele ;
Gurani, Sirwan Fernandez ;
Pinholt, Else Marie ;
Cattaneo, Paolo Maria .
DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (08)
[8]   Airway volume for different dentofacial skeletal patterns [J].
El, Hakan ;
Palomo, Juan Martin .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 139 (06) :E511-E521
[9]   Cone-beam computed tomography for routine orthodontic treatment planning: A radiation dose evaluation [J].
Garcia Silva, Maria Alves ;
Wolf, Ulrich ;
Heinicke, Frank ;
Bumann, Axel ;
Visser, Heiko ;
Hirsch, Edgar .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (05) :640.e1-640.e5
[10]   Effects of Craniofacial Morphology on Nasal Respiratory Function and Upper Airway Morphology [J].
Gong, Xu ;
Li, Weiran ;
Gao, Xuemei .
JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (07) :1717-1722