Partial Discharge Testing of Aerospace Electrical Systems

被引:22
作者
Alrumayan, Faisal
Cotton, Ian [1 ]
Nelms, Andrew [1 ]
机构
[1] Univ Manchester, Sch Elect & Elect Engn, Elect Energy & Power Syst Grp, Manchester M60 1QD, Lancs, England
关键词
VOLTAGE; INSULATION; CORONA;
D O I
10.1109/TAES.2010.5461661
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Modern aircraft are using more electrical equipment and are therefore using higher voltages. These higher voltage systems will become increasingly common in the future. The forms of systems that are being used operate under frequencies/waveshapes different from those normally used on ground based electrical power systems, and the testing regimes are relatively undeveloped in comparison with the other standardized tests available for aerospace components. The reasons why higher voltage systems in aircraft may be susceptible to partial discharge are first introduced. Then two electrical test techniques that can be used to measure partial discharge activity are introduced. One of these, the balanced technique, is used to examine the partial discharge performance of four test objects that are stressed with high voltages at varying frequencies of both sine and square waveforms. The results that are presented show that, while the level of damage that can be attributed to partial discharges can be significantly increased as frequency rises, the inception voltage of such discharges does not significantly vary.
引用
收藏
页码:848 / 863
页数:16
相关论文
共 36 条
[1]  
Abdel-Salam M., 2000, High-Voltage Engineering: Theory and Practice, V2nd
[2]  
[Anonymous], 2001, 60270 IEC
[3]  
Bilodeau T. M., 1989, IEEE Electrical Insulation Magazine, V5, P12, DOI 10.1109/57.19137
[4]  
BROCKSCHMIDT A, 1999, INT C EL MACH DRIV I
[5]  
*BS EN ISO, 1996, 7864 BS EN ISO
[6]   Effect of supply voltage frequency on testing of insulation system [J].
Cavallini, A ;
Montanari, GC .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (01) :111-121
[7]   Memory propagation of negative point-to-plane corona under AC voltage [J].
Chang, C ;
Su, Q .
IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2002, 149 (03) :117-126
[8]  
DOBBS B, 1989, P 24 INT EN CONV ENG
[9]  
DUNBAR W, 1989, P 24 INT EN CONV ENG
[10]  
DUNBAR WG, 1998, 1998 23 INT POW MOD