Accuracy of intraocular lens power calculation in eyes with keratoconus

被引:0
|
作者
Kojima, Takashi [1 ,2 ]
Horai, Rie [3 ]
Isogai, Naoki [3 ]
Nakamura, Tomoaki [3 ]
Tamaoki, Akeno [4 ]
Ichikawa, Kazuo [5 ]
机构
[1] Japanese Red Cross Gifu Hosp, Ophthalmol, Gifu, Japan
[2] Keio Univ, Sch Med, Ophthalmol, Nagoya, Aichi, Japan
[3] Nagoya Eye Clin, Ophthalmol, Nagoya, Aichi, Japan
[4] JCHO Chukyo Hosp, Ophthalmol, Nagoya, Aichi, Japan
[5] Chukyo Eye Clin, Nagoya, Aichi, Japan
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
2209
引用
收藏
页数:3
相关论文
共 50 条
  • [11] Reply to Comment on: Accuracy of Intraocular Lens Formulas in Eyes With Keratoconus
    Wang, Kendrick M.
    Jun, Albert S.
    Ladas, John G.
    Siddiqui, Aazim A.
    Woreta, Fasika
    Srikumaran, Divya
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 218 : 355 - 356
  • [12] Accuracy of 14 intraocular lens power calculation formulas in extremely long eyes
    Li, Xinxin
    Song, Chunyuan
    Wang, Yong
    Wang, Jing
    Tang, Qiongyan
    Wu, Zheming
    Zhou, Yanwen
    Sun, Juan
    Jia, Yanhong
    Lin, Zhenlin
    Li, Shaowei
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (11) : 3619 - 3628
  • [13] Intraocular lens power calculation in keratoconus; A review of literature
    Ghiasian, Leila
    Abolfathzadeh, Navid
    Manafi, Navid
    Hadavandkhani, Ali
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2019, 31 (02): : 127 - 134
  • [14] Intraocular lens power calculation in cases with posterior keratoconus
    Tamaoki, Akeno
    Kojima, Takashi
    Hasegawa, Asato
    Nakamura, Hideki
    Tanaka, Kiyoshi
    Ichikawa, Kazuo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10): : 2190 - 2195
  • [15] Accuracy of intraocular lens power formulas in eyes with keratoconus: Multi-center study in Japan
    Yokogawa, Tomohiro
    Mori, Yosai
    Torii, Hidemasa
    Goto, So
    Hasegawa, Yumi
    Kojima, Takashi
    Kamiya, Kazutaka
    Shiba, Takuya
    Miyata, Kazunori
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (06) : 1839 - 1845
  • [16] Accuracy of intraocular lens power formulas in eyes with keratoconus: Multi-center study in Japan
    Tomohiro Yokogawa
    Yosai Mori
    Hidemasa Torii
    So Goto
    Yumi Hasegawa
    Takashi Kojima
    Kazutaka Kamiya
    Takuya Shiba
    Kazunori Miyata
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 1839 - 1845
  • [17] Intraocular lens power calculation in short eyes
    Gavin, E. A.
    Hammond, C. J.
    EYE, 2008, 22 (07) : 935 - 938
  • [18] Intraocular lens power calculation in short eyes
    E A Gavin
    C J Hammond
    Eye, 2008, 22 : 935 - 938
  • [19] Intraocular lens calculation accuracy limits in normal eyes
    Preussner, Paul-Rolf
    Olsen, Thomas
    Hoffmann, Peter
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (05): : 802 - 808
  • [20] Calculating intraocular lens power in eyes with keratoconus using videokeratography