Computer simulation with TRNSYS for a mobile refrigeration system incorporating a phase change thermal storage unit

被引:45
作者
Liu, Ming [1 ]
Saman, Wasim [1 ]
Bruno, Frank [1 ]
机构
[1] Univ S Australia, Barbara Hardy Inst, Mawson Lakes, SA 5095, Australia
关键词
Phase change material; Thermal energy storage; Refrigerated transport; Refrigeration system; TRNSYS; ENERGY-STORAGE; PERFORMANCE ENHANCEMENT; COOLING APPLICATIONS; HEAT-STORAGE;
D O I
10.1016/j.apenergy.2014.06.066
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a new TRNSYS model of a refrigeration system incorporating phase change material (PCM) for mobile transport. The PCTSU is charged by an off-vehicle refrigeration unit and the PCM provides cooling when discharging and the cooling released is utilized to cool down the refrigerated space. The advantage of this refrigeration system compared to a conventional system is that it consumes less energy and produces significantly lower greenhouse gas emissions. A refrigeration system for a typical refrigerated van is modelled and simulations are performed with climatic data from four different locations. The main components of the TRNSYS model are Type 88 (cooling load estimation) and Type 300 (new PCTSU component), accompanied by other additional components. The results show that in order to maintain the temperature of the products at -18 degrees C for 10 h, a total of 250 kg and 390 kg of PCM are required for no door opening and 20 door openings during the transportation, respectively. In addition, a parametric study is carried out to evaluate the effects of location, size of the refrigerated space, number of door openings and melting temperature of the PCM on the thermal performance. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:226 / 235
页数:10
相关论文
共 31 条
[1]   LOW-TEMPERATURE LATENT-HEAT THERMAL-ENERGY STORAGE - HEAT-STORAGE MATERIALS [J].
ABHAT, A .
SOLAR ENERGY, 1983, 30 (04) :313-332
[2]   Validated TRNSYS model for forced circulation solar water heating systems with flat plate and heat pipe evacuated tube collectors [J].
Ayompe, L. M. ;
Duffy, A. ;
McCormack, S. J. ;
Conlon, M. .
APPLIED THERMAL ENGINEERING, 2011, 31 (8-9) :1536-1542
[3]   Performance enhancement of a household refrigerator by addition of latent heat storage [J].
Azzouz, K. ;
Leducq, D. ;
Gobin, D. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (05) :892-901
[4]  
Bahaj AS, 1998, RENEW ENERG, V15, P572, DOI 10.1016/S0960-1481(98)00227-4
[5]   Minimising energy usage for domestic cooling with off-peak PCM storage [J].
Bruno, F. ;
Tay, N. H. S. ;
Belusko, M. .
ENERGY AND BUILDINGS, 2014, 76 :347-353
[6]   Experimental development of an intelligent refrigeration system [J].
Buzelin, LOS ;
Amico, SC ;
Vargas, JVC ;
Parise, JAR .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (02) :165-175
[7]   Recrystallization of ice during bulk storage of ice cream [J].
Donhowe, DP ;
Hartel, RW .
INTERNATIONAL DAIRY JOURNAL, 1996, 6 (11-12) :1209-1221
[8]  
DOWNING CC, 1993, ASHRAE TRAN, V99, P356
[9]  
GARRABRANT MA, 2003, ASHRAE T, V109, P401
[10]  
Gosney W.B., 1975, Proceedings of the Institute of Refrigeration, P31