Selective and Sensitive Chemiluminescence Determination of MCPB: Flow Injection and Liquid Chromatography

被引:5
作者
Meseguer-Lloret, Susana [1 ]
Torres-Cartas, Sagrario [1 ]
Catala-Icardo, Monica [1 ]
Gomez-Benito, Carmen [1 ]
机构
[1] Univ Politecn Valencia, Inst Invest Gest Integrada Zonas Costeras, E-46022 Valencia, Spain
关键词
MCPB; Flow injection; Liquid chromatography; High-performance liquid chromatography; HPLC; Chemiluminescence; Photoreactor; Solid phase extraction; SPE; SOLID-PHASE EXTRACTION; CHLOROPHENOXY ACID HERBICIDES; DIODE-ARRAY DETECTION; GC-MS ANALYSIS; PHOTOINDUCED CHEMILUMINESCENCE; WATER SAMPLES; POSTCOLUMN CHEMILUMINESCENCE; PHENOXYACID HERBICIDES; ENVIRONMENTAL WATERS; AQUEOUS SAMPLES;
D O I
10.1177/0003702815620133
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Two new chemiluminescence (CL) methods are described for the determination of the herbicide 4-(4-chloro-o-tolyloxy) butyric acid (MCPB). First, a flow injection chemiluminescence (FI-CL) method is proposed. In this method, MCPB is photodegraded with an ultraviolet (UV) lamp and the photoproducts formed provide a great CL signal when they react with ferricyanide in basic medium. Second, a high-performance liquid chromatography chemiluminescence (HPLC-CL) method is proposed. In this method, before the photodegradation and CL reaction, the MCPB and other phenoxyacid herbicides are separated in a C18 column. The experimental conditions for the FI-CL and HPLC-CL methods are optimized. Both methods present good sensitivity, the detection limits being 0.12 mu g L-1 and 0.1 mu g L-1 (for FI-CL and HPLC-CL, respectively) when solid phase extraction (SPE) is applied. Intra-and interday relative standard deviations are below 9.9%. The methods have been satisfactorily applied to the analysis of natural water samples. FI-CL method can be employed for the determination of MCPB in simple water samples and for the screening of complex water samples in a fast, economic, and simple way. The HPLC-CL method is more selective, and allows samples that have not been resolved with the FI-CL method to be solved.
引用
收藏
页码:312 / 321
页数:10
相关论文
共 50 条
  • [31] Sensitive determination of nanogram levels of diacerein in a pharmaceutical formulation by flow injection chemiluminescence analysis
    Han-Chun Yao
    Xiao-Feng Yang
    Hua Li
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2007, 54 (04) : 949 - 956
  • [32] Sensitive determination of a β-lactam antibiotic, cefaclor by liquid chromatography with chemiluminescence detection
    Kai, M
    Kinoshita, H
    Ohta, K
    Hara, S
    Lee, MK
    Lu, JZ
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 30 (06) : 1765 - 1771
  • [33] Sensitive Determination of Hemoglobin in Human Blood and Serum by Flow Injection Coupled with Chemiluminescence Detection
    Cao Jun-tao
    Wang Hui
    Chen Yong-hong
    Liu Yan-ming
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (01) : 241 - 245
  • [34] A sensitive photoinduced chemiluminescence method for the determination of riboflavin with flow injection analysis
    Zhang, GF
    Chen, HY
    ANALYTICAL LETTERS, 2000, 33 (15) : 3285 - 3302
  • [35] Determination of Mancozeb and Maneb using flow injection chemiluminescence detection
    Asghar, Muhammad
    Yaqoob, Mohammad
    Munawar, Nusrat
    Nabi, Abdul
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (11) : 2586 - 2606
  • [36] Determination of nimodipine by flow injection chemiluminescence method
    Zhao, YJ
    Lang, HY
    Zhang, XJ
    Jiang, YR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (03) : 345 - 347
  • [37] Determination of rutin by flow injection chemiluminescence method
    Li Li-Jun
    Zhong Zhao-Heng
    Feng Jun
    Chen Qi-Feng
    Kong Hong-Xing
    Wu Jian-ling
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27 (08) : 1625 - 1628
  • [38] Determination of propranolol hydrochloride by flow injection chemiluminescence
    Rao, ZM
    Wu, QL
    Xie, GP
    Xu, HH
    Zhang, XQ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (12) : 1660 - 1662
  • [39] Determination of melamine by flow injection analysis based on chemiluminescence system
    Zeng, Hua-jin
    Yang, Ran
    Wang, Qing-wen
    Li, Jian-jun
    Qu, Ling-bo
    FOOD CHEMISTRY, 2011, 127 (02) : 842 - 846
  • [40] Flow-injection chemiluminescence determination of fluoroquinolones
    Rao, Y
    Tong, Y
    Zhang, XR
    Luo, GA
    Baeyens, WRG
    ANALYTICAL LETTERS, 2000, 33 (06) : 1117 - 1129