Selective and Sensitive Chemiluminescence Determination of MCPB: Flow Injection and Liquid Chromatography

被引:5
作者
Meseguer-Lloret, Susana [1 ]
Torres-Cartas, Sagrario [1 ]
Catala-Icardo, Monica [1 ]
Gomez-Benito, Carmen [1 ]
机构
[1] Univ Politecn Valencia, Inst Invest Gest Integrada Zonas Costeras, E-46022 Valencia, Spain
关键词
MCPB; Flow injection; Liquid chromatography; High-performance liquid chromatography; HPLC; Chemiluminescence; Photoreactor; Solid phase extraction; SPE; SOLID-PHASE EXTRACTION; CHLOROPHENOXY ACID HERBICIDES; DIODE-ARRAY DETECTION; GC-MS ANALYSIS; PHOTOINDUCED CHEMILUMINESCENCE; WATER SAMPLES; POSTCOLUMN CHEMILUMINESCENCE; PHENOXYACID HERBICIDES; ENVIRONMENTAL WATERS; AQUEOUS SAMPLES;
D O I
10.1177/0003702815620133
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Two new chemiluminescence (CL) methods are described for the determination of the herbicide 4-(4-chloro-o-tolyloxy) butyric acid (MCPB). First, a flow injection chemiluminescence (FI-CL) method is proposed. In this method, MCPB is photodegraded with an ultraviolet (UV) lamp and the photoproducts formed provide a great CL signal when they react with ferricyanide in basic medium. Second, a high-performance liquid chromatography chemiluminescence (HPLC-CL) method is proposed. In this method, before the photodegradation and CL reaction, the MCPB and other phenoxyacid herbicides are separated in a C18 column. The experimental conditions for the FI-CL and HPLC-CL methods are optimized. Both methods present good sensitivity, the detection limits being 0.12 mu g L-1 and 0.1 mu g L-1 (for FI-CL and HPLC-CL, respectively) when solid phase extraction (SPE) is applied. Intra-and interday relative standard deviations are below 9.9%. The methods have been satisfactorily applied to the analysis of natural water samples. FI-CL method can be employed for the determination of MCPB in simple water samples and for the screening of complex water samples in a fast, economic, and simple way. The HPLC-CL method is more selective, and allows samples that have not been resolved with the FI-CL method to be solved.
引用
收藏
页码:312 / 321
页数:10
相关论文
共 50 条
  • [21] Determination of urapidil by flow injection chemiluminescence
    Lang, HY
    Li, YR
    Zhang, WP
    Zhang, XJ
    Shen, YH
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (04): : 618 - 620
  • [22] Flow injection chemiluminescence determination of hydrazine
    Safavi, A
    Baezzat, MR
    ANALYTICA CHIMICA ACTA, 1998, 358 (02) : 121 - 125
  • [23] Flow injection chemiluminescence determination of paracetamol
    Ruengsitagoon, Wirat
    Liawruangrath, Saisunee
    Townshend, Alan
    TALANTA, 2006, 69 (04) : 976 - 983
  • [24] Chemiluminescence flow injection determination of bismuth
    Baezzat, Mohammad R.
    Bahrani, Roza
    LUMINESCENCE, 2010, 25 (02) : 106 - 106
  • [25] Flow injection chemiluminescence determination of tetracyclines
    Li, Z
    Feng, ML
    Lu, JR
    Gong, ZL
    Jiang, HL
    ANALYTICAL LETTERS, 1997, 30 (04) : 797 - 807
  • [26] Determination of diquat by flow injection–chemiluminescence
    J. L. López-Paz
    M. Catalá-Icardo
    B. Antón-Garrido
    Analytical and Bioanalytical Chemistry, 2009, 394 : 1073 - 1079
  • [27] Chemiluminescence detection flow cells for flow injection analysis and high-performance liquid chromatography
    Jessica M. Terry
    Stephan Mohr
    Peter R. Fielden
    Nick J. Goddard
    Neil W. Barnett
    Don C. Olson
    Duane K. Wolcott
    Paul S. Francis
    Analytical and Bioanalytical Chemistry, 2012, 403 : 2353 - 2360
  • [28] Determination of phenols by flow injection and liquid chromatography with on-line quinine-sensitized photo-oxidation and quenched luminol chemiluminescence detection
    Zhang, W
    Danielson, ND
    ANALYTICA CHIMICA ACTA, 2003, 493 (02) : 167 - 177
  • [29] Flow-injection chemiluminescence determination of gentamicin: optimization by central composite design
    Iranifam, M.
    Hasanzadeh, A.
    Fathinia, M.
    Khataee, A. R.
    Mousavi, S. A.
    LUMINESCENCE, 2014, 29 (03) : 230 - 238
  • [30] A sensitive procedure for the rapid determination of arsenic(III) by flow injection analysis and chemiluminescence detection
    Satienperakul, S
    Cardwell, TJ
    Kolev, SD
    Lenehan, CE
    Barnett, NW
    ANALYTICA CHIMICA ACTA, 2005, 554 (1-2) : 25 - 30