A novel sensitive electrochemical sensor based on in-situ polymerized molecularly imprinted membranes at graphene modified electrode for artemisinin determination

被引:88
作者
Bai, Huiping [1 ]
Wang, Chunqiong [1 ]
Chen, Jing [1 ]
Peng, Jun [1 ]
Cao, Qiue [1 ]
机构
[1] Yunnan Univ, Minist Educ, Key Lab Med Chem Nat Resource, Sch Chem Sci & Technol, Kunming 650091, Peoples R China
基金
中国国家自然科学基金; 国家教育部博士点专项基金资助;
关键词
Artemisinin; Graphene; Electrochemical sensor; Molecular imprinted membrane; In-situ polymerization; PERFORMANCE LIQUID-CHROMATOGRAPHY; ANNUA L; CARBON NANOTUBES; MASS-SPECTROMETRY; ACID; FILM; NANOPARTICLES; QUANTIFICATION; EXTRACTS; LAYER;
D O I
10.1016/j.bios.2014.09.034
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To develop a rapid and simple method for sensitive determination of artemisinin (ART) in complicated matrices, a novel electrochemical sensor was constructed by in-situ polymerization of ART-imprinted membranes (ART-MIMs) on the surface of graphene (G) modified glassy carbon electrode (GCE) using acrylamide (AM) as functional monomer, ethylene glycol dimethacrylate (EGDMA) as cross-linking agent after the experimental parameters for the preparation of ART-MIMs such as functional monomer, molar ratio of template, monomer and cross-linking agent together with extraction condition were optimized. Under the optimal conditions, the sensor named as ART-MIM/G/GCE exhibited a good selectivity, high sensitivity and considerably better resistance against some analogs of artemisinin such as dihydroartemisinin (DHA), artemether (ARM) and artesunate (ARTS). The calibration graph for the determination of artemisinin by the sensor was linear in the range of 1.0 x 10(-8) mol L-1 to 4.0 x 10(-5) mol L-1 with the detection limit of 2.0 x 10(-9) mol L-1. Meanwhile, this sensor possessed of good regeneration, stability and practicability. It could retain more than 94% of its original response after used at least 80 times or stored in water at room temperature for 60 days. The obtained sensor was successfully applied to determine the contents of artemisinin in the extract of Artemisia annua L with the relative standard deviation (RSD) of less than 3.5% (n=5). (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:352 / 358
页数:7
相关论文
共 33 条
  • [1] Fast and reliable artemisinin determination from different Artemisia annua leaves based alimentary products by high performance liquid chromatography-tandem mass spectrometry
    Carra, Andrea
    Bagnati, Renzo
    Fanelli, Roberto
    Bonati, Maurizio
    [J]. FOOD CHEMISTRY, 2014, 142 : 114 - 120
  • [2] Analysis of artemisinin by a packed-column supercritical fluid chromatography-atmospheric pressure chemical ionisation mass spectrometry technique
    Dost, K
    Davidson, G
    [J]. ANALYST, 2003, 128 (08) : 1037 - 1042
  • [3] Fu Chuan, 2012, Zhongguo Zhong Yao Za Zhi, V37, P2964
  • [4] Photopolymerization and photostructuring of molecularly imprinted polymers for sensor applications-A review
    Fuchs, Yannick
    Soppera, Olivier
    Haupt, Karsten
    [J]. ANALYTICA CHIMICA ACTA, 2012, 717 : 7 - 20
  • [5] Characterization of binding sites in molecularly imprinted polymers
    Garcia-Calzon, J. A.
    Diaz-Garcia, M. E.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (02) : 1180 - 1194
  • [6] Plastic antibodies: developments and applications
    Haupt, K
    Mosbach, K
    [J]. TRENDS IN BIOTECHNOLOGY, 1998, 16 (11) : 468 - 475
  • [7] Molecular imprinted polymer sensors: Implications for therapeutics
    Hillberg, AL
    Brain, KR
    Allender, CJ
    [J]. ADVANCED DRUG DELIVERY REVIEWS, 2005, 57 (12) : 1875 - 1889
  • [8] Molecularly imprinted polymers based electrochemical sensor for bovine hemoglobin recognition
    Kan, Xianwen
    Xing, Zonglan
    Zhu, Anhong
    Zhao, Zhe
    Xu, Guilin
    Li, Chen
    Zhou, Hong
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 168 : 395 - 401
  • [9] Extraction of artemisinin and artemisinic acid from Artemisia annua L. using supercritical carbon dioxide
    Kohler, M
    Haerdi, W
    Christen, P
    Veuthey, JL
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 785 (1-2) : 353 - 360
  • [10] Molecularly imprinted sensor based on electropolmerized poly(o-phenylenediamine) membranes at reduced graphene oxide modified electrode for imidacloprid determination
    Kong, Lei
    Jiang, Xiaoying
    Zeng, Yanbo
    Zhou, Tianshu
    Shi, Guoyue
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 185 : 424 - 431