Evaluation of attention, perception, and stress levels of clinical cardiovascular perfusionists during cardiac operations: a pilot study

被引:13
作者
Merkle, Frank [1 ]
Kurtovic, Dino [1 ]
Starck, Christoph [1 ]
Pawelke, Cynthia [2 ]
Gierig, Sina [2 ]
Falk, Volkmar [1 ,3 ]
机构
[1] German Heart Ctr Berlin, Augustenburger Pl 1, D-13353 Berlin, Germany
[2] Berlin Inst Technol, Berlin, Germany
[3] Charite Univ Med Berlin, Dept Cardiovasc Surg, Berlin, Germany
来源
PERFUSION-UK | 2019年 / 34卷 / 07期
关键词
eye-tracking; cardiopulmonary bypass; perfusion; stress level; cardiac surgery; COGNITIVE LOAD;
D O I
10.1177/0267659119828563
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Performing cardiopulmonary bypass is a complex task which involves evaluating visual input from patient monitors and technical parameters displayed at the heart-lung machine console as well as reacting to other sensory input. Only few studies are available concerning the competency requirements for clinical cardiovascular perfusionists, including attention, perception, and coping with mental stress. This study aims at evaluating attention, perception, and stress levels of clinical cardiovascular perfusionists during cardiopulmonary bypass. Methods: Nine clinical cardiovascular perfusionists voluntarily offered to participate in the study. Participants were asked to wear Tobii 2 eye-tracking glasses throughout the procedures. Specific time points were analyzed (cardiopulmonary bypass on, initial cardioplegia delivery, steady state, cross-clamp off, and weaning from cardiopulmonary bypass). Data acquisition was supplemented by participants' self-evaluation regarding their stress levels and by National Aeronautics and Space Administration Task Load Index (NASA TLX) questionnaires. Results: Seven datasets were sufficient to be evaluated. The clinical cardiovascular perfusionists' professional experience ranged from 0.5 to 24 years. Evaluation of eye-tracking data revealed large variations in areas of interest hits, fixation, and dwell times. Across all phases, the venous reservoir, mean arterial pressure, arterial pump display, cardioplegia control, and data management system received the highest levels of attention. Pupil diameter measurements increased at start of cardiopulmonary bypass, cardioplegia delivery, and weaning off, but returned to base level during steady state. Clinical cardiovascular perfusionists' self-evaluation showed that subjective stress level was highest at the start and the end of the procedure. NASA TLX questionnaires revealed medium-to-high mental and temporal workloads, but low physical workloads. Performance, effort, and frustration indices showed medium workloads. Conclusion: During cardiopulmonary bypass, perfusionists are subjected to stress. Peak stress levels were highest during start and end of cardiopulmonary bypass. Furthermore, visual attention and perception varied between the operative phases. Further studies are indicated to evaluate the design of heart-lung machines and stress-coping strategies during cardiopulmonary bypass.
引用
收藏
页码:544 / 551
页数:8
相关论文
共 13 条
  • [1] FRIDAY PJ, 1991, J SOC OCCUP MED, V41, P151
  • [2] HART S G, 1988, P139
  • [3] Holmqvist K., 2011, EYE TRACKING COMPREH
  • [4] Which competencies are necessary for clinical perfusion in Germany? Interviews with perfusionists
    Merkle, Frank
    [J]. PERFUSION-UK, 2007, 22 (03): : 201 - 205
  • [5] Morris Richard W, 2007, J Extra Corpor Technol, V39, P228
  • [6] Pupil diameter as a measure of cognitive load during auditory-visual interference in a simple piloting task
    Peysakhovich, Vsevolod
    Dehais, Frederic
    Causse, Mickael
    [J]. 6TH INTERNATIONAL CONFERENCE ON APPLIED HUMAN FACTORS AND ERGONOMICS (AHFE 2015) AND THE AFFILIATED CONFERENCES, AHFE 2015, 2015, 3 : 5199 - 5205
  • [7] The Use of Task-Evoked Pupillary Response as an Objective Measure of Cognitive Load in Novices and Trained Physicians: A New Tool for the Assessment of Expertise
    Szulewski, Adam
    Roth, Nathan
    Howes, Daniel
    [J]. ACADEMIC MEDICINE, 2015, 90 (07) : 981 - 987
  • [8] Eye tracking for skills assessment and training: a systematic review
    Tien, Tony
    Pucher, Philip H.
    Sodergren, Mikael H.
    Sriskandarajah, Kumuthan
    Yang, Guang-Zhong
    Darzi, Ara
    [J]. JOURNAL OF SURGICAL RESEARCH, 2014, 191 (01) : 169 - 178
  • [9] Eye-tracking analysis of skilled performance in clinical extracorporeal circulation
    Tomizawa, Yasuko
    Aoki, Hirotaka
    Suzuki, Satoshi
    Matayoshi, Toru
    Yozu, Ryohei
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2012, 15 (02) : 146 - 157
  • [10] Is the "sterile cockpit'' concept applicable to cardiovascular surgery critical intervals or critical events? The impact of protocol-driven communication during cardiopulmonary bypass
    Wadhera, Rishi K.
    Henrickson, Sarah
    Burkhart, Harold M.
    Greason, Kevin L.
    Neal, James R.
    Levenick, Katherine M.
    Wiegmann, Douglas A.
    Sundt, Thoralf M., III
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (02) : 312 - 319