The effect of sacral fracture malreduction on the safe placement of iliosacral screws

被引:94
作者
Reilly, MC
Bono, CM
Litkouhi, T
Sirkin, M
Behrens, FF
机构
[1] Univ Med & Dent New Jersey, Dept Orthopaed Surg, Newark, NJ USA
[2] Manhattan Coll, Sch Engn, Bronx, NY USA
关键词
sacral fracture; iliosacral screws; displacement; safe screw insertion;
D O I
10.1097/00005131-200302000-00002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To determine the effects of cranial displacement on the safe placement of iliosacral screws for zone 11 sacral fractures. Design: Computer imaging and dimensional analysis of a human cadaveric sacral fracture model. Setting: Cadaveric dissection, Orthopaedic Research Laboratories, Newark, New Jersey. Main Outcome Measurements: Six cadaveric pelves with simulated zone 11 sacral fractures were imaged with computed tomography at controlled cranial displacements of 5, 10, 15, and 20 mm. The area of contact at the fracture site and volume of bone available for iliosacral screw placement was graphically measured using both two- and three-dimensional computer modeling. Areas of contact were also represented in terms of the maximal number of 7.0-mm screws that could be simultaneously implanted. Results: Cross-sectional contact area was decreased by 30%, 56%, 81%, and 90% at 5, 10, 15 and 20 mm of displacement, respectively. Volume of bone was decreased by 21%, 25%, 26%, and 34% for 5, 10, 15 and 20 mm of displacement, respectively. In 50% of the specimens at 15 mm and 66% of the specimens with 20 mm displacement, two iliosacral screws could not be contained simultaneously within bone. In 17% of the specimens displaced 15 mm and 50% of the specimens displaced 20 mm, the cross-sectional area was insufficient to contain a single iliosacral screw. Conclusions: Although previous authors have accepted up to 15 mm of cranial displacement, the data demonstrate substantial compromise of available screw space with displacements greater than I cm. Fracture reduction is mandatory, as screw placement with residual displacement of 10 mm or more can endanger adjacent neural and vascular structures.
引用
收藏
页码:88 / 94
页数:7
相关论文
共 18 条
[1]   Safe placement of S1 and S2 iliosacral screws:: The "vestibule" concept [J].
Carlson, DA ;
Scheid, DK ;
Maar, DC ;
Baele, JR ;
Kaehr, DM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (04) :264-269
[2]  
DENIS F, 1988, CLIN ORTHOP RELAT R, P67
[3]  
EBRAHEIM NA, 1994, SPINE, V19, P721
[4]  
EBRAHEIM NA, 1994, CLIN ORTHOP RELAT R, V307, P222
[5]   Imaging assessment of sacroiliac screw placement relative to the neuroforamen [J].
Goldberg, BA ;
Lindsey, RW ;
Foglar, C ;
Hedrick, TD ;
Miclau, T ;
Hadad, JL .
SPINE, 1998, 23 (05) :585-589
[6]   THE EFFECT OF THREAD LENGTH AND LOCATION ON EXTRACTION STRENGTHS OF ILIOSACRAL LAG SCREWS [J].
KRAEMER, W ;
HEARN, T ;
TILE, M ;
POWELL, J .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1994, 25 (01) :5-9
[7]  
MATTA JM, 1996, CLIN ORTHOP RELAT R, V329, P199
[8]  
MATTA JM, 1989, CLIN ORTHOP RELAT R, V242, P83
[9]  
POHLEMANN T, 1992, ORTHOPADE, V21, P400
[10]  
Routt MLC, 1997, J ORTHOP TRAUMA, V11, P584