Table-top laser-driven ultrashort electron and X-ray source: the CIBER-X source project

被引:19
作者
Girardeau-Montaut, JP
Kiraly, B
Girardeau-Montaut, C
Leboutet, H
机构
[1] Univ Lyon 1, Lab Sci & Ingn Surfaces, F-69622 Villeurbanne, France
[2] Attila Jozsef Univ, Dept Expt Phys, H-6720 Szeged, Hungary
[3] DRIF, DPTA, SP2A, CEA B3, F-91680 Bruyeres Le Chatel, France
关键词
pulsed electron source; pulsed X-ray source; laser-driven source; low-dose imagery;
D O I
10.1016/S0168-9002(00)00419-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the development of a new laser-driven table-top ultrashort electron and X-ray source, also called the CIBER-X source (1). X-ray pulses are produced by a three-step process which consists of the photoelectron emission from a thin metallic photocathode illuminated by 16 ps duration laser pulses at 213 nm. The e-gun is a standard Pierce diode electrode type, in which electrons are accelerated by a cw electric field of similar to 11 MV/m up to a hole made in the anode. The photoinjector produces a train of 70-80 keV electron pulses of similar to 0.5 nC and 20 A peak current at a repetition rate of 10 Hz. The electrons are then transported outside the diode along a path of 20 cm length, and are focused onto a target of thullium by magnetic fields produced by two electromagnetic coils. X-rays are then produced by the impact of electrons on the target. Simulations of geometrical, electromagnetic fields and energetic characteristics of the complete source were performed previously with the assistance of the code PIXEL1 also developed at the laboratory. Finally, experimental electron and X-ray performances of the CIBER-X source as well as its application to very low dose imagery are presented and discussed. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:361 / 370
页数:10
相关论文
共 18 条
[1]   A PICOSECOND ELECTRON-GUN FOR SURFACE-ANALYSIS [J].
AESCHLIMANN, M ;
HULL, E ;
CAO, J ;
SCHMUTTENMAER, CA ;
JAHN, LG ;
GAO, Y ;
ELSAYEDALI, HE ;
MANTELL, DA ;
SCHEINFEIN, MR .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1000-1009
[2]  
BARTY CPJ, 1995, SPIES P, V2523, P316
[3]  
Chen PS, 1997, AIP CONF PROC, P95, DOI 10.1063/1.52977
[4]   DESIGN OF A PULSED X-RAY SYSTEM FOR FLUORESCENT LIFETIME MEASUREMENTS WITH A TIMING ACCURACY OF 109 PS [J].
DERENZO, SE ;
MOSES, WW ;
BLANKESPOOR, SC ;
ITO, M ;
OBA, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (03) :629-631
[5]  
ELSAYEDALI HE, 1990, REV SCI INSTRUM, V61, P1646
[6]  
FOERSTER E, 1998, SPIES S OPT SCI ENG, V3451
[7]  
GIRARDEAUMONTAU.C, PIXEL1 IS SIMULATION
[8]   SCALING LAW FOR TEMPORAL DISPERSION OF A SHORT ELECTRON PULSE ACROSS A DIODE IN SPACE-CHARGE REGIME [J].
GIRARDEAUMONTAUT, C ;
GIRARDEAUMONTAUT, JP ;
LEBOUTET, H .
APPLIED PHYSICS LETTERS, 1989, 55 (24) :2556-2558
[9]   SPACE-CHARGE-LIMITED CURRENT-DENSITY AS A FUNCTION OF ELECTRON FLOW DURATION IN AN EMISSIVE DIODE [J].
GIRARDEAUMONTAUT, JP ;
GIRARDEAUMONTAUT, C .
JOURNAL OF APPLIED PHYSICS, 1989, 65 (08) :2889-2895
[10]   Picosecond dynamics of a hot solid-density plasma [J].
Kieffer, JC ;
Jiang, Z ;
Ikhlef, A ;
Cote, CY ;
Peyrusse, O .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1996, 13 (01) :132-137