A whole-thermoplastic microfluidic chip with integrated on-chip micropump, bioreactor and oxygenator for cell culture applications

被引:15
作者
Ameri, Amir Reza [1 ,2 ,3 ]
Imanparast, Armin [1 ,4 ,5 ]
Passandideh-Fard, Mohammad [3 ]
Shaegh, Seyed Ali Mousavi [1 ,2 ,6 ]
机构
[1] Mashhad Univ Med Sci, BuAli Res Inst, Lab Microfluid & Med Microsyst, Mashhad, Iran
[2] Mashhad Univ Med Sci, Orthoped Res Ctr, Mashhad, Iran
[3] Ferdowsi Univ Mashhad, Dept Mech Engn, Mashhad, Iran
[4] Mashhad Univ Med Sci, Med Phys Res Ctr, Mashhad, Iran
[5] Mashhad Univ Med Sci, Fac Med, Dept Med Phys, Mashhad, Iran
[6] Mashhad Univ Med Sci, Ghaem Hosp, Clin Res Unit, Mashhad, Iran
基金
美国国家科学基金会;
关键词
Microfluidics; Thermoplastic; Diffuser -nozzle micropump; Numerical simulation; On -chip cell culture; DIFFUSER ELEMENTS; POLYURETHANE; PLATFORM; DEVICES;
D O I
10.1016/j.aca.2022.340093
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microfluidics provides enabling platforms for various cell culture, drug testing and synthesis of drug carriers using chip-based microsystems. In this study, we present a novel integrated whole-thermoplastic microfluidic chip to provide a platform for on-chip cell culture at static and dynamic conditions. The whole chip was made of polymethyl methacrylate (PMMA) and thermoplastic polyurethane (TPU) using high precision micromilling and laser micromachining, assembled by thermal fusion bonding. Prior to fabricate the integrated microchip, a pneumatic solo diffuser-nozzle micropump was fabricated and characterized to evaluate its functionality for on -chip pumping. Then the micropump was integrated with a microbioreactor and an oxygenator in a microchip for flow pumping required for on-chip cell culture. Oxygenator, made of a thin TPU membrane and a reservoir, was implemented in the microchip because of low oxygen permeability of PMMA. To design the oxygenator for sufficient oxygen delivery to the chip, numerical simulation was performed using COMSOL Multiphysics (R) to evaluate oxygen concentration distribution inside the microchip. Finally, the diffuser-nozzle micropump was integrated with the oxygenator and a bioreactor on the microchip for cell culture with on-chip pumping. Culture of DFW cells was performed on the integrated chip for three days, and cell survival was evaluated with Trypan Analytica Chimica Acta 1221 (2022) 340093 Blue assay. The findings reveal that the proposed integrated chip with on-chip pumping could be employed for conducting various cell culture studies.
引用
收藏
页数:10
相关论文
共 58 条
  • [1] A valve-less diffuser micropump for microfluidic analytical systems
    Andersson, H
    van der Wijngaart, W
    Nilsson, P
    Enoksson, P
    Stemme, G
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (03) : 259 - 265
  • [2] Cells Under Stress: An Inertial-Shear Microfluidic Determination of Cell Behavior
    Armistead, Fern J.
    Gala De Pablo, Julia
    Gadelha, Hermes
    Peyman, Sally A.
    Evans, Stephen D.
    [J]. BIOPHYSICAL JOURNAL, 2019, 116 (06) : 1127 - 1135
  • [3] Long-term monitoring of bacteria undergoing programmed population control in a microchemostat
    Balagaddé, FK
    You, LC
    Hansen, CL
    Arnold, FH
    Quake, SR
    [J]. SCIENCE, 2005, 309 (5731) : 137 - 140
  • [4] On the performance analysis of gas-actuated peristaltic micropumps
    Banejad, Amirhesam
    Shaegh, Seyed Ali Mousavi
    Ramezani-Fard, Elias
    Seifi, Parisa
    Passandideh-Fard, Mohammad
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2020, 315 (315)
  • [5] Design, fabrication and experimental characterization of whole-thermoplastic microvalves and micropumps having micromilled liquid channels of rectangular and half-elliptical cross-sections
    Banejad, Amirhesam
    Passandideh-Fard, Mohammad
    Niknam, Hamidreza
    Hosseini, Mohammad Javad Mirshojaeian
    Shaegh, Seyed Ali Mousavi
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2020, 301
  • [6] Engineers are from PDMS-land, Biologists are from Polystyrenia
    Berthier, Erwin
    Young, Edmond W. K.
    Beebe, David
    [J]. LAB ON A CHIP, 2012, 12 (07) : 1224 - 1237
  • [7] A liver-on-a-chip platform with bioprinted hepatic spheroids
    Bhise, Nupura S.
    Manoharan, Vijayan
    Massa, Solange
    Tamayol, Ali
    Ghaderi, Masoumeh
    Miscuglio, Mario
    Lang, Qi
    Zhang, Yu Shrike
    Shin, Su Ryon
    Calzone, Giovanni
    Annabi, Nasim
    Shupe, Thomas D.
    Bishop, Colin E.
    Atala, Anthony
    Dokmeci, Mehmet R.
    Khademhosseini, Ali
    [J]. BIOFABRICATION, 2016, 8 (01)
  • [8] Thermoplastic Elastomer (TPE)-Poly(Methyl Methacrylate) (PMMA) Hybrid Devices for Active Pumping PDMS-Free Organ-on-a-Chip Systems
    Busek, Mathias
    Novik, Steffen
    Aizenshtadt, Aleksandra
    Amirola-Martinez, Mikel
    Combriat, Thomas
    Grunzner, Stefan
    Krauss, Stefan
    [J]. BIOSENSORS-BASEL, 2021, 11 (05):
  • [9] Pumps for microfluidic cell culture
    Byun, Chang Kyu
    Abi-Samra, Kameel
    Cho, Yoon-Kyoung
    Takayama, Shuichi
    [J]. ELECTROPHORESIS, 2014, 35 (2-3) : 245 - 257
  • [10] Beyond Polydimethylsiloxane: Alternative Materials for Fabrication of Organ-on-a-Chip Devices and Microphysiological Systems
    Campbell, Scott B.
    Wu, Qinghua
    Yazbeck, Joshua
    Liu, Chuan
    Okhovatian, Sargol
    Radisic, Milica
    [J]. ACS BIOMATERIALS SCIENCE & ENGINEERING, 2021, 7 (07) : 2880 - 2899