PET with a dual-head coincidence camera: Spatial resolution, scatter fraction, and sensitivity

被引:0
作者
Kunze, WD [1 ]
Baehre, M [1 ]
Richter, E [1 ]
机构
[1] Med Univ Lubeck, Clin Radiotherapy & Nucl Med, D-23538 Lubeck, Germany
关键词
PET; coincidence scintillation camera; spatial resolution; scatter fraction; sensitivity;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Scintillation cameras with options for detecting positron annihilation quanta in the coincidence acquisition mode may be the most innovative diagnostic devices introduced in nuclear medicine during the last few years. Besides conventional low-energy imaging in the collimated single-photon mode, these options offer a relatively inexpensive opportunity to perform uncollimated PET by switching into the coincidence acquisition mode. Instead of collimators, scatter frames (with 2 optional configurations: axial or open scatter frame) can be mounted to reduce the amount of quanta reaching the detectors from parts of the patient's body outside the field of view. This study investigates the coincidence imaging properties of the scintillation camera by measuring spatial resolution, scatter fraction, sensitivity, and count-rate response for F-18, Methods: A needle in air and a plastic tube in water, each filled with F-18, were oriented axially and transversally to measure the transverse and axial spatial resolutions, respectively. Using either the axial or the open scatter frame, a standard cylinder filled homogeneously with activity was studied over several half-life periods to deduce the respective scatter and random fractions of the system by means of a sinogram technique. The activity of the cylinder was kept low to determine the sensitivity to coincidence events for both scatter frames. Results: Depending on the distance between the line source and the axis of rotation and on the choice of the axial acceptance angle used to reconstruct the coincidence events (single-slice rebinning algorithm), the axial resolution was found to be between 6 and 10 mm (full width at half maximum) with the axial scatter frame mounted. The transversal resolution was 6-6.5 mm on the axis of rotation, independent of the scatter frame used. The scatter fraction amounted to roughly 25% for the axial and 38% for the open scatter frames. The sensitivity when measuring true coincidence pairs ran to nearly 650 Hz/kBq/mL, when acquisition was performed with the axial scatter frame using a 30%-wide photopeak energy window. When acquiring with the open scatter frame, the sensitivity increased to nearly 3000 Hz/kBq/mL. Using the axial scatter frame, the homogeneously filled cylinder could be scanned with a maximum true coincidence rate of 2000 Hz for an activity of 55-60 MBq. Although this maximum true coincidence counting rate did not change significantly when the acquisition was performed with the open scatter frame, the respective activity in the standard cylinder was decreased to 10-15 MBq. Conclusion: The spatial resolution of the scintillation camera is sufficient for high-resolution coincidence imaging. Compared with a dedicated PET scanner, the scatter fraction is relatively high and should therefore be corrected adequately. The relatively low sensitivity and the rather low maximum true coincidence counting rate are considerably inferior compared with a conventional PET scanner. However, these drawbacks can be partially compensated for, facilitating its clinical use.
引用
收藏
页码:1067 / 1074
页数:8
相关论文
共 28 条
  • [21] Single-acquisition method for simultaneous determination of extrinsic gamma-camera sensitivity and spatial resolution
    Santos, J. A. M.
    Sarmento, S.
    Alves, P.
    Torres, M. C.
    Bastos, A. L.
    Ponte, F.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (01) : 44 - 49
  • [22] Dual-layer collimator for improved spatial resolution in SPECT with CZT camera: an analytical and Monte Carlo study
    Boutaghane, Nasreddine
    Hesse, Michel
    Bouzid, Boualem
    Zaidi, Habib
    Jamar, Francois
    Walrand, Stephan
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (06)
  • [23] Novel preclinical PET geometrical concept using a monolithic scintillator crystal offering concurrent enhancement in spatial resolution and detection sensitivity: a simulation study
    Sanaat, Amirhossein
    Arabi, Hossein
    Ay, Mohammad Reza
    Zaidi, Habib
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (04)
  • [24] Performance evaluation of the MOLECUBES β-CUBE-a high spatial resolution and high sensitivity small animal PET scanner utilizing monolithic LYSO scintillation detectors
    Krishnamoorthy, Srilalan
    Blankemeyer, Eric
    Mollet, Pieter
    Surti, Suleman
    Van Holen, Roel
    Karp, Joel S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15)
  • [25] Physical effects of mechanical design parameters on photon sensitivity and spatial resolution performance of a breast-dedicated PET system
    Spanoudaki, V. C.
    Lau, F. W. Y.
    Vandenbroucke, A.
    Levin, C. S.
    MEDICAL PHYSICS, 2010, 37 (11) : 5838 - 5849
  • [26] Evaluation of Collimators in a High-Resolution, Whole-Body SPECT/CT Device with a Dual-Head Cadmium-Zinc-Telluride Detector for 123I-FP-CIT SPECT
    Hiraki, Hitoshi
    Ito, Toshimune
    Onoguchi, Masahisa
    Tsuchikame, Hirotatsu
    Shishido, Masaaki
    Maeno, Takafumi
    Shibutani, Takayuki
    Sanada, Hiroki
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2023, 51 (03) : 227 - 234
  • [27] Deep Hybrid 2-D-3-D CNN Based on Dual Second-Order Attention With Camera Spectral Sensitivity Prior for Spectral Super-Resolution
    Li, Jiaojiao
    Wu, Chaoxiong
    Song, Rui
    Li, Yunsong
    Xie, Weiying
    He, Lihuo
    Gao, Xinbo
    IEEE TRANSACTIONS ON NEURAL NETWORKS AND LEARNING SYSTEMS, 2023, 34 (02) : 623 - 634
  • [28] Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard
    Matsumoto, K
    Kitamura, K
    Mizuta, T
    Tanaka, K
    Yamamoto, S
    Sakamoto, S
    Nakamoto, Y
    Amano, M
    Murase, K
    Senda, M
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (01) : 83 - 90