摘要
In I-123-IBZM brainSPECT, the main interest is the activity uptake in the striatum relative to the background, and semi-quantitative techniques using regions of interest are typically used for this purpose. Uncertainties in the measured uptakes can however be a problem due to low contrasts and high noise levels. Like SPECT in general, IBZM SPECT should benefit from reconstruction methods that include model-based compensation, but it is important that image acquisition is optimized for this technique. An important factor is the choice of collimator. In this study we compare four different parallel-hole collimators for IBZM SPECT regarding overall quantitative accuracy and measured uptake ratio as a function of image noise and uncertainty. The collimators are low-energy high-resolution (LEHR), low-energy general-purpose (LEGP), extended LEGP (ELEGP) and medium-energy general-purpose (MEGP). The effect of three Butterworth post-filters with cut-off frequencies of 0.3, 0.45 and 0.6 cm(-1) ( power factor 8) is also studied. All raw-data projections are produced using Monte Carlo simulations. Of the investigated collimators, the one that is most sensitive to the primary photons, ELEGP, proved to be the most optimal for realistic noise levels. Butterworth post-filtering is advantageous, and the cut-off frequency 0.45 cm(-1) was the best compromise in this study.
引用
收藏
页码:1971 / 1988
页数:18
相关论文
共 27 条
[1]  
Anger H.O., 1967, INSTRUMENTATION NUCL, V1, P485
[2]  
[Anonymous], 2003, ICRP PUBL
[3]   Attenuation correction in quantitative SPECT of cerebral blood flow:: a Monte Carlo study [J].
Ärlig, Å ;
Gustafsson, A ;
Jacobsson, L ;
Ljungberg, M ;
Wikkelsö, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12) :3847-3859
[4]   Quantification of dopaminergic neurotransmission SPECT studies with 123I-labelled radioligands.: A comparison between different imaging systems and data acquisition protocols using Monte Carlo simulation [J].
Crespo, Cristina ;
Gallego, Judith ;
Cot, Albert ;
Falcon, Carles ;
Bullich, Santiago ;
Pareto, Deborah ;
Aguiar, Pablo ;
Sempau, Josep ;
Lomena, Francisco ;
Calvino, Francisco ;
Pavia, Javier ;
Ros, Domenec .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (07) :1334-1342
[5]   Model-based compensation for quantitative 123I brain SPECT imaging [J].
Du, Y ;
Tsui, BMW ;
Frey, EC .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (05) :1269-1282
[6]  
Frey E. C., 1996, 1996 IEEE Nuclear Science Symposium Conference Record (Cat. No.96CH35974), P1082, DOI 10.1109/NSSMIC.1996.591559
[7]  
FREY EC, 1992, CONFERENCE RECORD OF THE 1992 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE, VOLS 1 AND 2, P1035, DOI 10.1109/NSSMIC.1992.301467
[8]   Possible impact of dopamine SPECT on decision-making for drug treatment in Parkinsonian syndrome [J].
Hesse, S. ;
Oehlwein, C. ;
Barthel, H. ;
Schwarz, J. ;
Polster, D. ;
Wagner, A. ;
Sabri, O. .
JOURNAL OF NEURAL TRANSMISSION, 2006, 113 (09) :1177-1190
[9]  
Hutton BF, 1997, EUR J NUCL MED, V24, P797
[10]   Application of distance-dependent resolution compensation and post-reconstruction filtering for myocardial SPECT [J].
Hutton, BF ;
Lau, YH .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06) :1679-1693