Speciation, Preconcentration and Determination of Inorganic Chromium Species in Spring, Drinking, and Waste Water Samples

被引:4
作者
Kabak, Burcu [1 ]
Arslan, Yasin [2 ]
Trak, Digdem [1 ]
Kenduzler, Erdal [1 ]
机构
[1] Burdur Mehmet Akif Ersoy Univ, Fac Arts & Sci, Chem Dept, TR-15030 Burdur, Turkey
[2] Burdur Mehmet Akif Ersoy Univ, Fac Arts & Sci, Nanosci & Nanotechnol Dept, TR-15030 Burdur, Turkey
关键词
Amberlite CG-120 resin; speciation; inorganic chromium species; water samples;
D O I
10.3103/S1063455X21010082
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
In general, chromium is existed in stable oxidation states, such as Cr(III) and Cr(VI) in the environment. While a certain amount of Cr(III) is required for human metabolism, Cr(VI) is known to have toxic and carcinogenic effects for all living species. Chromium compounds are widely used in different fields, such as electroplating, dyeing, photographic and textile industries. Owing to this reason, it and its compounds can easily interfere with the water resources. Because of differences in toxicity, it is important to develop a sensitive analytical method for the speciation, preconcentration and determination of chromium species in the water resources. In this work, speciation and preconcentration of Cr(III) and Cr(VI) were performed using Amberlite CG-120 resin before detection step by flame atomic absorption spectrometry. The experimental conditions for model solutions were optimized so that Cr(III) was adsorbed in a column while Cr(VI) was not. To perform this, some experimental parameters, such as pH, eluent' type/concentration/flow rate, sample solution flow rate and adsorbent amount were optimized. Furthermore, Cr(VI) was reduced to Cr(III) to determine total chromium. Then, Cr(VI) was calculated by the differences between total chromium and Cr(III). The limit of detection (3 s) and preconcentration factor were found to be 0.3 mu g L-1 and 600, respectively. This proposed method was successfully applied for the determination of inorganic chromium species in the different spring waters supplied from Isparta province (Eyupler Village), Burdur province (Aglasun County), the commercial drinking water samples purchased from local market in Burdur province, and the waste water supplied from Isparta province (Suleyman Demirel Organized Industrial Region) at Turkey. The accuracy of the method was successfully checked by certified reference material (TMDA-70.2 Ontario Lake water) at 95% confidence level.
引用
收藏
页码:46 / 52
页数:7
相关论文
共 50 条
  • [41] Ultrasound-assisted cloud point extraction for speciation and indirect spectrophotometric determination of chromium(III) and (VI) in water samples
    Hashemi, Mandi
    Daryanavard, Seyed Mosayeb
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2012, 92 : 189 - 193
  • [42] Magnetic nanoparticles as sorbent for preconcentration and determination of lead in fish and water samples
    M. Khajeh
    E. Sanchooli
    Journal of Applied Spectroscopy, 2011, 78 : 414 - 420
  • [43] Speciation Analysis of Chromium by Adsorptive Stripping Voltammetry in Tap and River Water Samples
    Grabarczyk, Malgorzata
    ELECTROANALYSIS, 2008, 20 (20) : 2217 - 2222
  • [44] Bentonite-based functional material as preconcentration system for determination of chromium species in water by flow injection analysis technique
    Amran, Muhammad Bachri
    Aminah, Sitti
    Rusli, Handajaya
    Buchari, Buchari
    HELIYON, 2020, 6 (05)
  • [45] A simple separation/preconcentration method for the determination of aluminum in drinking water and biological sample
    Khan, Sumaira
    Kazi, Tasneem G.
    Kolachi, Nida F.
    Baig, Jameel A.
    Afridi, Hassan I.
    Shah, Faheem
    DESALINATION, 2011, 281 : 215 - 220
  • [46] Heat-treated Saccharomyces cerevisiae for antimony speciation and antimony(III) preconcentration in water samples
    Marcellino, Sebastien
    Attar, Hossein
    Lievremont, Didier
    Lett, Marie-Claire
    Barbier, Frederique
    Lagarde, Florence
    ANALYTICA CHIMICA ACTA, 2008, 629 (1-2) : 73 - 83
  • [47] MAGNETIC NANOPARTICLES AS SORBENT FOR PRECONCENTRATION AND DETERMINATION OF LEAD IN FISH AND WATER SAMPLES
    Khajeh, M.
    Sanchooli, E.
    JOURNAL OF APPLIED SPECTROSCOPY, 2011, 78 (03) : 414 - 420
  • [48] Speciation, preconcentration and determination of lead in natural water using chelating resin and direct GFAAS
    Ososkov, VK
    Chou, CC
    Kebbekus, BB
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1998, 69 (01) : 1 - 12
  • [49] Determination of inorganic arsenic species by hydride generation atomic absorption spectrometry in water samples after preconcentration/separation on nano ZrO2/B2O3 by solid phase extraction
    Erdogan, Hakan
    Yalcinkaya, Ozcan
    Turker, Ali Rehber
    DESALINATION, 2011, 280 (1-3) : 391 - 396
  • [50] Comparative Study of Two Different Speciation Methods for the Determination of Hexavalent Chromium in Water Samples Using Electrothermal Atomic Absorption Spectrometry
    Kostakis, M. G.
    Pasias, I. N.
    Borova, V. L.
    Panara, A. K.
    Thomaidis, N. S.
    CURRENT ANALYTICAL CHEMISTRY, 2013, 9 (02) : 288 - 295