Numerical study on split base plate connection with concentric anchors between steel-plate composite wall and concrete basemat

被引:6
作者
Sadeghi, Hadis Vakili [1 ]
Mirghaderi, Seyed Rasoul [1 ]
Epackachi, Siamak [2 ]
Asgarpoor, Masoumeh [3 ]
Gharavi, Ali [3 ]
机构
[1] Univ Tehran, Civil Engn Dept, Tehran, Iran
[2] Amirkabir Univ Technol, Civil Engn Dept, Tehran, Iran
[3] Sharif Univ Technol, Civil Engn Dept, Tehran, Iran
关键词
concentric anchors; concrete basemat; rectangular steel-plate composite walls; split base plate connection; SC WALLS; DATABASE; DESIGN; BEHAVIOR;
D O I
10.1002/tal.1937
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel-plate composite (SC) walls can be connected to a concrete basemat using a base plate and a set of anchors eccentric to the wall. The base plate can be separated into two parts so that the concrete of the wall and basemat is cohesive, and thus, the wall can be manufactured more easily and economically. Additionally, compression and shear demand are directly transferred from infill concrete to concrete basemat. Another change in the base plate connection of available tested walls involves transferring anchors to the bottom of faceplates. As a result of this modification, the base plate is removed from the force transmission chain, and the force is transferred directly from the wall to the anchors. After presenting the design criteria for this type of connection, three test walls with concrete foundations were verified in LS-Dyna. The walls were modeled with a split base plate connection and concentric anchors, and then compared to other types of wall-basemat connections. Three rectangular sections were then chosen as benchmarks and modeled with three anchors of different sizes to evaluate the effect of this parameter on walls behavior. The design equations presented for the single base plate connection were found applicable to design split base plate connections. Then all walls were compared to the test wall-fixed base wall connection. Finally, the models were analyzed with elastic walls to determine whether the foundation is stronger than the wall. The split base plate connection with concentric anchors was found to be stronger than connected parts and can be an alternative to existing connections.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Fragility functions for steel-plate concrete composite shear walls
    Mohammadgholibeyki, Negar
    Epackachi, Siamak
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 167
  • [2] Steel-Plate Composite Wall-to-Reinforced Concrete Wall Mechanical Connection-Part 1: Out-of-Plane Flexural Strength
    Seo, Jungil
    Anwar, Hassan S.
    Varma, Amit H.
    Nam, Yoonho
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 2022, 59 (01): : 31 - 51
  • [3] Modular steel-plate composite (SC) wall steelbricks: Experimental and numerical evaluations
    Sener, Kadir C.
    Varma, Amit H.
    Wang, Sijia
    Bhardwaj, Saahastaranshu R.
    Gallocher, Stewart
    NUCLEAR ENGINEERING AND DESIGN, 2019, 350 : 224 - 233
  • [4] Steel-Plate Composite Wall-to-Wall T-Joints: Joint Shear Strength
    Seo, Jungil
    Varma, Amit H.
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (07)
  • [5] Finite element modeling of steel-plate concrete composite wall piers
    Epackachi, Siamak
    Whittaker, Andrew S.
    Varma, Amit H.
    Kurt, Efe G.
    ENGINEERING STRUCTURES, 2015, 100 : 369 - 384
  • [6] Behavior of Steel-Plate Composite Wall Piers under Biaxial Loading
    Bhardwaj, Saahastaranshu R.
    Varma, Amit H.
    Orbovic, Nebojsa
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (02)
  • [7] Seismic analysis and design of steel-plate concrete composite shear wall piers
    Epackachi, Siamak
    Whittaker, Andrew S.
    Aref, Amjad
    ENGINEERING STRUCTURES, 2017, 133 : 105 - 123
  • [8] Steel-Plate Composite Wall to Reinforced Concrete Wall Mechanical ConnectionPart 2: In-Plane and Out-Of-Plane Shear Strength
    Anwar, Hassan S.
    Seo, Jungil
    Varma, Amit H.
    Nam, Yoonho
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 2023, 60 (01): : 31 - 59
  • [9] Behavior and design of square hollow section (SHS) support member directly welded to the face plate of steel-plate composite (SC) wall connection
    Xu, Haitao
    Zhou, Feng
    Du, Xiaodong
    Su, Song
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 229
  • [10] Shear performance of single steel-plate concrete composite beams with various transverse reinforcement configurations
    Wang, Bai-Xiang
    Ding, Ran
    Fan, Jian-Sheng
    Cai, Li-Jian
    Feng, Zhi-Mao
    Wang, Cui-Kun
    ENGINEERING STRUCTURES, 2022, 270