Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement

被引:20
作者
Ardestani, Marzieh M. [1 ]
Amenabar Edwards, Pedro P. [2 ]
Wimmer, Markus A. [1 ]
机构
[1] Rush Univ, Med Ctr, Dept Orthoped Human Mot Anal & Tribol, 1611 W Harrison St,Suite 204, Chicago, IL 60612 USA
[2] Pontificia Univ Catolica Chile, Dept Traumatol & Ortopedia, Santiago, Chile
关键词
ARTHROPLASTY; STABILITY; BEARINGS; UHMWPE; DESIGN; NUMBER; THA;
D O I
10.1007/s11999-017-5293-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patient-specific gait and surgical variables are known to play an important role in wear of total hip replacements (THR). However a rigorous model, capable of predicting wear rate based on a comprehensive set of subject-specific gait and component-positioning variables, has to our knowledge, not been reported. (1) Are there any differences between patients with high, moderate, and low wear rate in terms of gait and/or positioning variables? (2) Can we design a model to predict the wear rate based on gait and positioning variables? (3) Which group of wear factors (gait or positioning) contributes more to the wear rate? Data on patients undergoing primary unilateral THR who performed a postoperative gait test were screened for inclusion. We included patients with a 28-mm metal head and a hip cup made of noncrosslinked polyethylene (GUR 415 and 1050) from a single manufacturer (Zimmer, Inc). To calculate wear rates from radiographs, inclusion called for patients with a series of standing radiographs taken more than 1 year after surgery. Further, exclusion criteria were established to obtain reasonably reliable and homogeneous wear readings. Seventy-three (83% of included) patients met all criteria, and the final dataset consisted of 43 males and 30 females, 69 +/- 10 years old, with a BMI of 27.3 +/- 4.7 kg/m(2). Wear rates of these patients were determined based on the relative displacement of the femoral head with regard to the cup using a validated computer-assisted X-ray wear-analysis suite. Three groups with low (< 0.1 mm/year), moderate (0.1 to 0.2 mm/year), and high (> 0.2 mm/year) wear were established. Wear prediction followed a two-step process: (1) linear discriminant analysis to estimate the level of wear (low, moderate, or high), and (2) multiple linear and nonlinear regression modeling to predict the exact wear rate from gait and implant-positioning variables for each level of wear. There were no group differences for positioning and gait suggesting that wear differences are caused by a combination of wear factors rather than single variables. The linear discriminant analysis model correctly predicted the level of wear in 80% of patients with low wear, 87% of subjects with moderate wear, and 73% of subjects with high wear based on a combination of gait and positioning variables. For every wear level, multiple linear and nonlinear regression showed strong associations between gait biomechanics, implant positioning, and wear rate, with the nonlinear model having a higher prediction accuracy. Flexion-extension ROM and hip moments in the sagittal and transverse planes explained 42% to 60% of wear rate while positioning factors, (such as cup medialization and cup inclination angle) explained only 10% to 33%. Patient-specific wear rates are associated with patients' gait patterns. Gait pattern has a greater influence on wear than component positioning for traditional metal-on-polyethylene bearings. The consideration of individual gait bears potential to further reduce implant wear in THR. In the future, a predictive wear model may identify individual, modifiable wear factors for modern materials.
引用
收藏
页码:2027 / 2042
页数:16
相关论文
共 45 条
[1]  
Affatato S., 2014, Perspect. Total Hip Arthroplast, P19, DOI [10.1533/9781782420392.1.19, DOI 10.1533/9781782420392.1.19]
[2]   A novel total hip resurfacing design with improved range of motion and edge-load contact stress [J].
Alvarez-Vera, M. ;
Contreras-Hernandez, G. R. ;
Affatato, S. ;
Hernandez-Rodriguez, M. A. L. .
MATERIALS & DESIGN, 2014, 55 :690-698
[3]  
Andriacchi T. P., 1985, Biomechanics of Normal and Pathological Human Articulating Joints. Proceedings of the NATO Advanced Study Institute, P83
[4]  
[Anonymous], 2004, WILEY SER PROB STAT
[5]   A real-time topography of maximum contact pressure distribution at medial tibiofemoral knee implant during gait: Application to knee rehabilitation [J].
Ardestani, Marzieh M. ;
Moazen, Mehran ;
Chen, Zhenxian ;
Zhang, Jing ;
Jin, Zhongmin .
NEUROCOMPUTING, 2015, 154 :174-188
[6]   Gait modification and optimization using neural network-genetic algorithm approach: Application to knee rehabilitation [J].
Ardestani, Marzieh M. ;
Moazen, Mehran ;
Jin, Zhongmin .
EXPERT SYSTEMS WITH APPLICATIONS, 2014, 41 (16) :7466-7477
[7]   A neural network approach for determining gait modifications to reduce the contact force in knee joint implant [J].
Ardestani, Marzieh Mostafavizadeh ;
Chen, Zhenxian ;
Wang, Ling ;
Lian, Qin ;
Liu, Yaxiong ;
He, Jiankang ;
Li, Dichen ;
Jin, Zhongmin .
MEDICAL ENGINEERING & PHYSICS, 2014, 36 (10) :1253-1265
[8]   Human lower extremity joint moment prediction: A wavelet neural network approach [J].
Ardestani, Marzieh Mostafavizadeh ;
Zhang, Xuan ;
Wang, Ling ;
Lian, Qin ;
Liu, Yaxiong ;
He, Jiankang ;
Li, Dichen ;
Jin, Zhongmin .
EXPERT SYSTEMS WITH APPLICATIONS, 2014, 41 (09) :4422-4433
[9]   The number of subjects per variable required in linear regression analyses [J].
Austin, Peter C. ;
Steyerberg, Ewout W. .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2015, 68 (06) :627-636
[10]  
Australian Orthopaedic Association National Joint Replacement Registry, ANN REP 2015 HIP KNE