A hybrid process for leachate wastewater treatment: Evaporation and reverse osmosis/sequencing batch reactor

被引:9
作者
Bouchareb, Raouf [1 ]
Isik, Zelal [2 ]
Ozay, Yasin [3 ]
Karagunduz, Ahmet [4 ]
Keskinler, Bulent [4 ]
Dizge, Nadir [2 ]
机构
[1] Saleh Boubnider Univ, Proc Engn Fac, Dept Environm Engn, Constantine, Algeria
[2] Mersin Univ, Dept Environm Engn, TR-33343 Mersin, Turkey
[3] Tarsus Univ, Vocat Sch Tech Sci Mersin Tarsus Organized Ind Zo, Dept Environm Protect Technol, Mersin, Turkey
[4] Gebze Tech Univ, Dept Environm Engn, Kocaeli, Turkey
关键词
biological treatment; evaporation; leachate; reverse osmosis membrane; LANDFILL LEACHATE; BIOLOGICAL TREATMENT; RECIRCULATION; REMOVAL;
D O I
10.1002/wer.10717
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, a hybrid process for leachate wastewater treatment including evaporation and reverse osmosis (RO) membrane or biological treatment systems was suggested. Experiments were performed on a real landfill leachate wastewater. The leachate was subjected to evaporation; as a result, a distillate was obtained containing less organic matter and less substantial amounts of other pollutants, as ammonium salts and total phenols were removed. Tests were carried out at different evaporation temperatures and times. The initial leachate pH was adjusted and optimized. For optimum conditions, each of chemical oxygen demand (COD), total phenol, and ammonium salt concentrations were reduced to 99.99%, 95.00%, and 83.00%, respectively. The distillate of the first stage of the proposed process was then exposed to RO membrane system, as a first study, under different transmembrane pressure of 20, 30, and 40 bar and at different pH values of 7, 8, and 9. As a second suggested treatment system, the distillate was subjected to a biological treatment process for 30 days as a retention time, pH = 6, and room temperature 25 degrees C +/- 1 degrees C. At the end of the research study, a comparison was conducted between results obtained with RO membrane separation and biological treatment system as two distinct treatment systems proposed for leachate landfill wastewater treatment. Although both systems were effective for landfill leachate wastewater treatment, however, with the RO membrane separation system, COD removal efficiency reached 99.99%. In the other hand, with biological treatment process, COD elimination was as much as 90.00%. Certainly, evaporation and RO are not novel ways of landfill leachate treatment; however, few studies have attempted to use similar combined system for landfill leachate wastewater treatment and attained effective results of treated water. Practitioner Points A hybrid process of evaporation and RO membrane or biological treatment systems was suggested for leachate wastewater treatment. For optimum conditions, COD, total phenols, and ammonium salt reductions were achieved to 99.99%, 95%, and 83%, respectively, after the first evaporation stage. The distillate of the first stage of the proposed process was then exposed to RO membrane system and biological treatment system. Different transmembrane pressure and different pH values were optimized for RO.
引用
收藏
页数:10
相关论文
共 50 条
[31]   Combined treatment of landfill leachate with fecal supernatant in sequencing batch reactor. [J].
Zhou S.Q. ;
Zhang H.G. ;
Shi Y. .
Journal of Zhejiang University SCIENCE B, 2006, 7 (5) :397-403
[32]   Tratability of Tannery Wastewater Using a Sequencing Batch Reactor [J].
Pire Sierra, Maria Carolina ;
Palmero, Jhonny ;
Araujo, Ismenia ;
Diaz, Altamira .
REVISTA CIENTIFICA-FACULTAD DE CIENCIAS VETERINARIAS, 2010, 20 (03) :284-292
[33]   Coupling short-time sequencing batch reactor and coagulation-settling process for co-treatment of landfill leachate with raw municipal wastewater [J].
Trabelsi, Ismail ;
Salah, Sourour ;
Ounaeis, Faycal .
ARABIAN JOURNAL OF GEOSCIENCES, 2013, 6 (06) :2071-2079
[34]   Landfill leachate treatment using the sequencing batch biofilm reactor method integrated with the electro-Fenton process [J].
Dao-Bin Zhang ;
Xiao-Gang Wu ;
Yi-Si Wang ;
Hui Zhang .
Chemical Papers, 2014, 68 :782-787
[35]   Old Landfill Leachate and Municipal Wastewater Co-Treatment by Sequencing Batch Reactor Combined with Coagulation-Flocculation Using Novel Flocculant [J].
Kumar, Radhakrishnan Naresh ;
Sadaf, Somya ;
Verma, Mohini ;
Chakraborty, Shubhrasekhar ;
Kumari, Shweta ;
Polisetti, Veerababu ;
Kallem, Parashuram ;
Iqbal, Jawed ;
Banat, Fawzi .
SUSTAINABILITY, 2023, 15 (10)
[36]   Co-treatment of stabilized landfill leachate and municipal wastewater in a granular activated carbon-sequencing batch reactor (GAC-SBR) [J].
Verma, Mohini ;
Chakraborty, Shubhrasekhar ;
Kumari, Shweta ;
Gupta, Aalok ;
Kumar, Dewanshu ;
Iqbal, Jawed ;
Banu, J. Rajesh ;
Pugazhendi, Arulazhagan ;
Kumar, R. Naresh .
PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 174 :424-432
[37]   Treatment of landfill leachate by membrane processes of nanofiltration and reverse osmosis [J].
Kosutic, Kresimir ;
Dolar, Davor ;
Strmecky, Tea .
DESALINATION AND WATER TREATMENT, 2015, 55 (10) :2680-2689
[38]   Assessing an Integral Treatment for Landfill Leachate Reverse Osmosis Concentrate [J].
Tejera, Javier ;
Hermosilla, Daphne ;
Miranda, Ruben ;
Gasco, Antonio ;
Alonso, Victor ;
Negro, Carlos ;
Blanco, Angeles .
CATALYSTS, 2020, 10 (12) :1-17
[39]   Effectiveness of membrane bioreactor/reverse osmosis hybrid process for advanced purification of landfill leachate [J].
Elfilali, Nawal ;
Essafi, Nodar ;
Zait, Mohamed ;
Tahaikt, Mustapha ;
Elazhar, Fatima ;
Elmidaoui, Azzedine ;
Taky, Mohamed .
DESALINATION AND WATER TREATMENT, 2021, 240 :24-32
[40]   Achieving High-Efficiency Wastewater Treatment with Sequencing Batch Reactor Grundfos Technology [J].
Sionkowski, Tomasz ;
Halecki, Wiktor ;
Jasinski, Pawel ;
Chmielowski, Krzysztof .
PROCESSES, 2025, 13 (04)