Biomechanical comparison of sacroiliac screw techniques for unstable pelvic ring fractures

被引:163
作者
van Zwienen, CMA
van den Bosch, EW
Snijders, CJ
Kleinrensink, GJ
van Vugt, AB
机构
[1] Univ Nijmegen, Med Ctr, Dept Traumatol, NL-6500 HB Nijmegen, Netherlands
[2] Erasmus Univ, Dept Anat, Rotterdam, Netherlands
[3] Univ Rotterdam Hosp, Dept Traumatol, Rotterdam, Netherlands
关键词
sacroiliac screws; internal fixation; pelvis; sacral fracture; biomechanics;
D O I
10.1097/00005131-200410000-00002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To determine the stiffness and strength of various sacroiliac screw fixations to compare different sacroiliac screw techniques. Design: Randomized comparative study oil embalmed human pelvises. Materials and Methods: In 12 specimens, we created a symphysiolysis and sacral fractures oil both sides. Each of these 24 sacral fractures was fixed with 1 of the following methods: 1 sacroiliac screw in the vertebral body of S1,2 screws convergingly in S1. or 1 screw in S1 and 1 in S2. Oil the left and right side of a pelvis, different techniques were used. The pubic symphysis was not stabilized. We measured the translation and rotation stiffness of the fixations and the load to failure using a 3-dimensional video system. Results: The stiffness of the intact posterior pelvic ring was superior to any screw technique. Significant differences were found for the load to failure and rotation stiffness between the techniques with 2 screws and a single screw in S1. The techniques utilizing 2 screws showed no differences. Conclusions: Based on the results of this Study, we can conclude that a second sacroiliac screw in Completely unstable pelvic fractures increases rotation stiffness and improves the load to failure.
引用
收藏
页码:589 / 595
页数:7
相关论文
共 35 条
[1]  
ABELAZIZ YI, 1971, P ASP UI S CLOS RANG, P1
[2]  
Albert M J, 1993, J Orthop Trauma, V7, P226, DOI 10.1097/00005131-199306000-00005
[3]   Biomechanical comparison of posterior internal fixation techniques for unstable pelvic fractures [J].
Comstock, CP ;
vanderMeulen, MCH ;
Goodman, SB .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (08) :517-522
[4]   Experimental study of the sacroiliac joint micromotion in pelvic disruption [J].
Dujardin, FH ;
Roussignol, X ;
Hossenbaccus, M ;
Thornine, JM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (02) :99-103
[5]  
Duwelius P J, 1992, J Orthop Trauma, V6, P420, DOI 10.1097/00005131-199212000-00005
[6]  
EBRAHEIM NA, 1994, CLIN ORTHOP RELAT R, P222
[7]   Mobility of the first tarsometatarsal joint in relation to hallux valgus deformity: Anatomical and biomechanical aspects [J].
Faber, FWM ;
Kleinrensink, GJ ;
Verhoog, MW ;
Vijn, AH ;
Snijders, CJ ;
Mulder, PGH ;
Verhaar, JAN .
FOOT & ANKLE INTERNATIONAL, 1999, 20 (10) :651-656
[8]  
Hofmann D, 1991, Unfallchirurgie, V17, P247, DOI 10.1007/BF02588402
[9]   Early fixation of the vertically unstable pelvis: The role of iliosacral screw fixation of the posterior lesion [J].
Keating, JF ;
Werier, J ;
Blachut, P ;
Broekhuyse, H ;
Meek, RN ;
O'Brien, PJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (02) :107-113
[10]   UPGRADING OF EFFICIENCY IN THE TRACKING OF BODY MARKERS WITH VIDEO TECHNIQUES [J].
KEEMINK, CJ ;
VANDIJKE, GAH ;
SNIJDERS, CJ .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (01) :70-74