Correlation of iodine uptake and perfusion parameters between dual-energy CT imaging and first-pass dual-input perfusion CT in lung cancer

被引:36
作者
Chen, Xiaoliang [1 ]
Xu, Yanyan [1 ]
Duan, Jianghui [1 ]
Li, Chuandong [1 ]
Sun, Hongliang [1 ]
Wang, Wu [1 ]
机构
[1] China Japan Friendship Hosp, Dept Radiol, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
computed tomography; dual-energy CT; Lung cancer; perfusion CT; BENIGN PULMONARY NODULES; DIFFERENTIATION; CONTRAST; TUMORS; VOLUME; MAPS;
D O I
10.1097/MD.0000000000007479
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To investigate the potential relationship between perfusion parameters from first-pass dual-input perfusion computed tomography (DI-PCT) and iodine uptake levels estimated from dual-energy CT (DE-CT). The pre-experimental part of this study included a dynamic DE-CT protocol in 15 patients to evaluate peak arterial enhancement of lung cancer based on time-attenuation curves, and the scan time of DE-CT was determined. In the prospective part of the study, 28 lung cancer patients underwent whole-volume perfusion CT and single-source DE-CT using 320-row CT. Pulmonary flow (PF, mL/min/100 mL), aortic flow (AF, mL/min/100mL), and a perfusion index (PI= PF/[PF+AF]) were automatically generated by in-house commercial software using the dual-input maximum slope method for DI-PCT. For the dual-energy CT data, iodine uptake was estimated by the difference (lambda) and the slope (lambda HU). l was defined as the difference of CT values between 40 and 70KeV monochromatic images in lung lesions. lambda HU was calculated by the following equation: lambda HU= vertical bar lambda/(70 +/- 40)vertical bar . The DI-PCT and DE-CT parameters were analyzed by Pearson/Spearman correlation analysis, respectively. All subjects were pathologically proved as lung cancer patients (including 16 squamous cell carcinoma, 8 adenocarcinoma, and 4 small cell lung cancer) by surgery or CT-guided biopsy. Interobserver reproducibility in DI-PCT (PF, AF, PI) and DE-CT (l, lHU) were relatively good to excellent (intraclass correlation coefficient [ICC](Inter)=0.8726-0.9255, ICCInter=0.8179-0.8842; ICCInter= 0.8881-0.9177, ICCInter= 0.9820-0.9970, ICCInter= 0.9780-0.9971, respectively). Correlation coefficient between l and AF, and PF were as follows: 0.589 (P<. 01) and 0.383 (P<. 05). Correlation coefficient between lambda HU and AF, and PF were as follows: 0.564 (P<. 01) and 0.388 (P<. 05). Both the single-source DE-CT and dual-input CT perfusion analysis method can be applied to assess blood supply of lung cancer patients. Preliminary results demonstrated that the iodine uptake relevant parameters derived from DE-CT significantly correlated with perfusion parameters derived from DI-PCT.
引用
收藏
页数:7
相关论文
共 31 条
[1]   Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches [J].
Bae, Kyongtae T. .
RADIOLOGY, 2010, 256 (01) :32-61
[2]   Clinical Utility of Dual-Energy CT in the Evaluation of Solitary Pulmonary Nodules: Initial Experience [J].
Chae, Eun Jin ;
Song, Jae-Woo ;
Seo, Joon Beom ;
Krauss, Bernhard ;
Jang, Yu Mi ;
Song, Koun-Sik .
RADIOLOGY, 2008, 249 (02) :671-681
[3]   Pancreatic Endocrine Tumors: Tumor Blood Flow Assessed with Perfusion CT Reflects Angiogenesis and Correlates with Prognostic Factors [J].
d'Assignies, Gaspard ;
Couvelard, Anne ;
Bahrami, Stephane ;
Vullierme, Marie-Pierre ;
Hammel, Pascal ;
Hentic, Olivia ;
Sauvanet, Alain ;
Bedossa, Pierre ;
Ruszniewski, Philippe ;
Vilgrain, Valerie .
RADIOLOGY, 2009, 250 (02) :407-416
[4]   Pulmonary Perfused Blood Volume with Dual-Energy CT as Surrogate for Pulmonary Perfusion Assessed with Dynamic Multidetector CT [J].
Fuld, Matthew K. ;
Halaweish, Ahmed F. ;
Haynes, Susan E. ;
Divekar, Abhay A. ;
Guo, Junfeng ;
Hoffman, Eric A. .
RADIOLOGY, 2013, 267 (03) :747-756
[5]   Correlation between Dual-Energy and Perfusion CT in Patients with Hepatocellular Carcinoma [J].
Gordic, Sonja ;
Puippe, Gilbert D. ;
Krauss, Bernhard ;
Klotz, Ernst ;
Desbiolles, Lotus ;
Lesurtel, Mickael ;
Mullhaupt, Beat ;
Pfammatter, Thomas ;
Alkadhi, Hatem .
RADIOLOGY, 2016, 280 (01) :78-87
[6]   Dynamic contrast-enhanced CT in suspected lung cancer: quantitative results [J].
Harders, S. W. ;
Madsen, H. H. ;
Nellemann, H. M. ;
Rasmussen, T. R. ;
Thygesen, J. ;
Hager, H. ;
Andersen, N. T. ;
Rasmussen, F. .
BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1031)
[7]  
Henzler T, 2011, MED RADIOL DIAGN IMA, P101, DOI 10.1007/174_2010_53
[8]   Differentiation of Lung Cancers From Inflammatory Masses with Dual-Energy Spectral CT Imaging [J].
Hou, Wei Shu ;
Wu, Hua Wei ;
Yin, Yan ;
Cheng, Jie Jun ;
Zhang, Qing ;
Xu, Jian Rong .
ACADEMIC RADIOLOGY, 2015, 22 (03) :337-344
[9]   Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[10]   Whole-organ perfusion of the pancreas using dynamic volume CT in patients with primary pancreas carcinoma: acquisition technique, post-processing and initial results [J].
Kandel, Sonja ;
Kloeters, Christian ;
Meyer, Henning ;
Hein, Patrick ;
Hilbig, Andreas ;
Rogalla, Patrik .
EUROPEAN RADIOLOGY, 2009, 19 (11) :2641-2646