Comparative study of scintillation and dosimetric properties between Tm-doped CaF2 translucent ceramic and single crystal

被引:16
作者
Kawano, Naoki [1 ]
Nakauchi, Daisuke [2 ]
Fukuda, Kentaro [3 ]
Okada, Go [2 ]
Kawaguchi, Noriaki [2 ]
Yanagida, Takayuki [2 ]
机构
[1] Akita Univ, Grad Sch Engn Sci, Akita 0108502, Japan
[2] Nara Inst Sci & Technol NAIST, Grad Sch Sci & Technol, Ikoma, Nara 6300192, Japan
[3] Tokuyama Corp, Shunan, Yamaguchi 7458648, Japan
基金
日本科学技术振兴机构;
关键词
GLOW-CURVE; LIF-MG; CU; P DETECTORS; LUMINESCENCE; TLD-300; SPECTROSCOPY;
D O I
10.7567/JJAP.57.102401
中图分类号
O59 [应用物理学];
学科分类号
摘要
We fabricated a Tm-doped CaF2 translucent ceramic by spark plasma sintering (SPS), and evaluated its photoluminescence (PL), scintillation, and dosimetric properties compared with those of a single crystal. Both the samples exhibited emission peaks originating from the 4f-4f transitions of Tm3+ under visible-light and X-ray irradiation. The intensities of PL and scintillation for the single crystal were higher than those for the translucent ceramic. Regarding thermally stimulated luminescence (TSL), both the samples showed main glow peaks at approximately 145 and 265 degrees C. The Tm-doped translucent ceramic exhibited a higher TSL sensitivity than did the single crystal and showed a linear response against X-ray dose over the dose range from 0.01 to 1000 mGy. (C) 2018 The Japan Society of Applied Physics
引用
收藏
页数:4
相关论文
共 34 条
[1]  
Bhatt B.C., 2011, RADIAT PROT ENVIRON, V34, P6, DOI DOI 10.4103/0972-0464.93897
[2]   ULTRA-THIN LIF-MG,CU,P DETECTORS FOR BETA-DOSIMETRY [J].
BILSKI, P ;
OLKO, P ;
BURGKHARDT, B ;
PIESCH, E .
RADIATION MEASUREMENTS, 1995, 24 (04) :439-443
[3]   High sensitivity thermoluminescence dosimetry [J].
Bos, AJJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 184 (1-2) :3-28
[4]   Dosimetric properties of new cards with high-sensitivity MCP-N (LiF:Mg,Cu,P) detectors for Harshaw automatic reader [J].
Budzanowski, M. ;
Bilski, P. ;
Olko, P. ;
Ryba, E. ;
Perle, S. ;
Majewski, M. .
RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) :251-253
[5]   Optical spectroscopy of Tm3+ doped in KLa(MoO4)(2) crystals [J].
Cavalli, E ;
Meschini, C ;
Toncelli, A ;
Tonelli, M ;
Bettinelli, M .
JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 1997, 58 (04) :587-595
[6]   Retrospective dosimetry of populations exposed to reactor accident: Chernobyl example, lesson for Fukushima [J].
Chumak, Vadim V. .
RADIATION MEASUREMENTS, 2013, 55 :3-11
[7]  
Fujiwara T., 2012, Neutron News, V23, P31, DOI 10.1080/10448632.2012.725335
[8]   Remote optical fiber dosimetry [J].
Huston, AL ;
Justus, BL ;
Falkenstein, PL ;
Miller, RW ;
Ning, H ;
Altemus, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 184 (1-2) :55-67
[9]   The effects of heating rate on the dose response characteristics of TLD-200, TLD-300 and TLD-400 [J].
Kafadar, V. Emir ;
Yazici, A. Necmeddin ;
Yildirim, R. Gueler .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (19) :3337-3346
[10]   Comparative study of dosimeter properties between Al2O3 transparent ceramic and single crystal [J].
Kato, Takumi ;
Kawano, Naoki ;
Okada, Go ;
Kawaguchi, Noriaki ;
Yanagida, Takayuki .
RADIATION MEASUREMENTS, 2017, 107 :43-47