Amperometric sensor used for determination of thiocyanate with a silver nanoparticles modified electrode

被引:44
作者
Wang, GF
Li, MG
Gao, YC
Fang, B [1 ]
机构
[1] Anhui Normal Univ, Sch Chem, Wuhu 241000, Peoples R China
[2] Anhui Normal Univ, Sch Mat Sci, Wuhu 241000, Peoples R China
来源
SENSORS | 2004年 / 4卷 / 09期
关键词
silver nanoparticles; modified electrode; thiocyanate determination;
D O I
10.3390/s40900147
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel electrode modified with silver nanoparticles was fabricated. It is found that the reducibility of silver nanoparticles is higher than for bulk silver by comparing a silver nanoparticles modified electrode with a silver micro-disk electrode. When SCN- was added, a new oxidation peak occurred and the anodic peak current of silver nanoparticles decreased. The new anodic peak current is proportional to the thiocyanate concentration in the range of 5.0 x 10(-7) similar to4.0 x 10(-4) mol/L in pH 6.0 NaH2PO4-Na2HPO4 buffer solutions (PBS). The detection limit (S/N=3) is 4 x 10(-8) mol/L. This method has been applied to the determination of saliva (smoker and non-smoker).
引用
收藏
页码:147 / 155
页数:9
相关论文
共 16 条
  • [1] Semiconductor clusters, nanocrystals, and quantum dots
    Alivisatos, AP
    [J]. SCIENCE, 1996, 271 (5251) : 933 - 937
  • [2] Morphology-dependent electrochemistry of cytochrome c at Au colloid-modified SnO2 electrodes
    Brown, KR
    Fox, AP
    Natan, MJ
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (05) : 1154 - 1157
  • [3] INFLUENCE OF PORPHYRIN STRUCTURE ON ANION SELECTIVITIES OF MANGANESE(III) PORPHYRIN BASED MEMBRANE ELECTRODES
    CHANIOTAKIS, NA
    CHASSER, AM
    MEYERHOFF, ME
    GROVES, JT
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (02) : 185 - 188
  • [4] ORGANIZATION OF AU COLLOIDS AS MONOLAYER FILMS ONTO ITO GLASS SURFACES - APPLICATION OF THE METAL COLLOID FILMS AS BASE INTERFACES TO CONSTRUCT REDOX-ACTIVE MONOLAYERS
    DORON, A
    KATZ, E
    WILLNER, I
    [J]. LANGMUIR, 1995, 11 (04) : 1313 - 1317
  • [5] ANION-SELECTIVE ELECTRODES BASED ON A GOLD(III) TRIISOBUTYLPHOSPHINE SULFIDE COMPLEX
    FLORIDO, A
    BACHAS, LG
    VALIENTE, M
    VILLAESCUSA, I
    [J]. ANALYST, 1994, 119 (11) : 2421 - 2425
  • [6] Highly selective thiocyanate poly(vinyl chloride) membrane electrode based on a cadmium-Schiff's base complex
    Ganjali, MR
    Poursaberi, T
    Basiripour, F
    Salavati-Niasari, M
    Yousefi, M
    Shamsipur, M
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (08): : 1091 - 1095
  • [7] GAO D, 1994, ANAL CHEM, V6, P224
  • [8] Analysis of thiocyanate in biological fluids by capillary zone electrophoresis
    Glatz, Z
    Nováková, S
    Sterbová, H
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 916 (1-2) : 273 - 277
  • [9] PREPARATION AND CHARACTERIZATION OF AU COLLOID MONOLAYERS
    GRABAR, KC
    FREEMAN, RG
    HOMMER, MB
    NATAN, MJ
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (04) : 735 - 743
  • [10] Electroactivity Of Cu2+ at a thin film assembly of gold nanoparticles linked by 11-mercaptoundecanoic acid
    Israel, LB
    Kariuki, NN
    Han, L
    Maye, MM
    Luo, J
    Zhong, CJ
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 517 (1-2) : 69 - 76