Characterization and quality control of avalanche photodiode arrays for the Clear-PEM detector modules

被引:6
作者
Abreu, Conceicao
Amaral, Pedro
Carrico, Bruno
Ferreira, Miguel
Luyten, Joan
Moura, Rui
Ortigao, Catarina
Rato, Pedro
Varela, Joao
机构
[1] LIP, P-1000149 Lisbon, Portugal
[2] UALG, P-8000117 Faro, Portugal
[3] IST, P-1049001 Lisbon, Portugal
关键词
avalanche photodiode; dark current; gain; positron emission mammography; quality control;
D O I
10.1016/j.nima.2007.01.112
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Clear-PEM is a Positron Emission Mammography (PEM) prototype being developed in the framework of the Crystal Clear Collaboration at CERN. This device is a dedicated PET camera for mammography, based on LYSO:Ce scintillator crystals, Avalanche PhotoDiodes (APD) and a fast, low-noise electronics readout system, designed to examine both the breast and the axillary lymph node areas, and aiming at the detection of tumors down to 2 mm in diameter. The prototype has two planar detector heads, each composed of 96 detector modules. The Clear-PEM detector module is composed of a matrix of 32 identical 2 x 2 x 20 mm(3) LYSO:Ce crystals read at both ends by Hamamatsu S8550 APD arrays (4 x 8) for Depth-of-Interaction (Dol) capability. The APD arrays were characterized by the measurement of gain and dark current as a function of bias voltage, under controlled temperature conditions. Two independent setups were used. The full set of 398 APD arrays followed a well-defined quality control (QC) protocol, aiming at the rejection of arrays not complying within defined specifications. From a total of 398 arrays, only 2 (0.5%) were rejected, reassuring the trust in these detectors for prototype assembly and future developments. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:19 / 22
页数:4
相关论文
共 9 条
[1]   Design and evaluation of the Clear-PEM scanner for positron emission mammography [J].
Abreu, MC ;
Aguiar, JD ;
Almeida, FG ;
Almeida, P ;
Bento, P ;
Carrico, B ;
Ferreira, M ;
Ferreira, NC ;
Gonçalves, F ;
Leong, C ;
Lopes, F ;
Lousa, P ;
Martins, MV ;
Matela, N ;
Mendes, PR ;
Moura, R ;
Nobre, J ;
Oliveira, N ;
Ortigao, C ;
Peralta, L ;
Pereira, R ;
Rego, J ;
Ribeiro, R ;
Rodrigues, P ;
Sampaio, J ;
Santos, AI ;
Silva, L ;
Silva, JC ;
Sousa, P ;
Teixeira, IC ;
Teixeira, JP ;
Trindade, A ;
Varela, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :71-77
[2]   maxPET: A dedicated mammary and axillary region PET imaging system for breast cancer [J].
Doshi, NK ;
Silverman, RW ;
Shao, Y ;
Cherry, SR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :811-815
[3]   Dedicated PET scanners for breast imaging [J].
Freifelder, R ;
Karp, JS .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (12) :2463-2480
[4]   Clear-PEM, a dedicated PET camera for mammography [J].
Lecoq, P ;
Varela, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 486 (1-2) :1-6
[5]   Positron emission mammography imaging [J].
Moses, WW .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (1-2) :249-252
[6]   Positron emission mammographic instrument: Initial results [J].
Murthy, K ;
Aznar, M ;
Bergman, AM ;
Thompson, CJ ;
Robar, JL ;
Lisbona, R ;
Loutfi, A ;
Gagnon, JH .
RADIOLOGY, 2000, 215 (01) :280-285
[7]  
ORTIGAO C, 2006, EUROMEDIM 2006 MASC
[8]   POSITRON EMISSION MAMMOGRAPHY (PEM) - A PROMISING TECHNIQUE FOR DETECTING BREAST-CANCER [J].
THOMPSON, CJ ;
MURTHY, K ;
PICARD, Y ;
WEINBERG, IN ;
MAKO, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1012-1017
[9]   PET detector using waveshifting optical fibers and microchannel plate PMT with delay line readout [J].
Williams, MB ;
Sealock, RM ;
Majewski, S ;
Weisenberger, AG .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (02) :195-205