A protection and fault location scheme for EHV line with series capacitor based on travelling waves and wavelet analysis

被引:0
作者
Huang, ZJ [1 ]
Chen, YP [1 ]
Gong, QW [1 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Hebei, Peoples R China
来源
POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS | 2002年
关键词
edge detection; EHV line; fault location; identification; Lipschitz exponent; protection; series capacitor compensation; travelling waves; wavelet; wavelet modulus maxima;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A scheme based on wavelet for construction of the fast protection and fault location for series compensation is described in this paper. Current travelling waves, which are more easily captured than voltage waves, are used and decomposed into mode components. The line mode component is represented by its wavelet modulus maxima. The incident and reflection travelling waves are identified by analyzing the amplitudes and polarities of their wavelet modulus maxima. The interval between incident and reflection travelling waves reveals the fault position. EMTP simulations proved that the scheme is correct and effective.
引用
收藏
页码:290 / 294
页数:5
相关论文
共 50 条
  • [1] A fault location scheme for series compensation lines based on traveling waves and wavelet analysis
    Huang, ZJ
    Chen, YP
    IPEC 2003: Proceedings of the 6th International Power Engineering Conference, Vols 1 and 2, 2003, : 625 - 629
  • [2] Fault Location Estimation based on Wavelet Analysis of Traveling Waves
    Kale, Vijay
    Bhide, Sudhir
    Bedekar, Prashant
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [3] Travelling waves-based fault location scheme for feeders in power distribution network
    Shi, Shenxing
    Lei, Aoyu
    He, Xin
    Mirsaeidi, Sohrab
    Dong, Xinzhou
    JOURNAL OF ENGINEERING-JOE, 2018, (15): : 1326 - 1329
  • [4] Travelling wave fault location of transmission line using wavelet transform
    Qin, J
    Chen, XX
    Zheng, JC
    POWERCON '98: 1998 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - PROCEEDINGS, VOLS 1 AND 2, 1998, : 533 - 537
  • [5] Distance protection scheme with travelling wave for UHVDC transmission line based on wavelet transform
    long, Chen Shi
    Chun, Shu Hong
    zhi, Wang Yong
    Fang, Zeng
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 2162 - 2165
  • [6] A new fault location method avoiding wave speed and based on traveling waves for EHV transmission line
    Zhang Feng
    Liang Jun
    Zhang Li
    Yun Zhihao
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1753 - 1757
  • [7] Asynchronous fault location scheme for half-wavelength transmission lines based on propagation characteristics of voltage travelling waves
    Nan, Peng
    Cheng Menghan
    Rui, Liang
    Zare, Firuz
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (04) : 502 - 510
  • [8] Fault Location of Transmission Line based on Discrete Wavelet Transforms
    Tang Wenxiu
    Zhang Mo
    Liu Ying
    Lang Xufei
    Zhu Liangkuan
    FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE II, PTS 1-6, 2012, 121-126 : 1269 - 1273
  • [9] A Protection Coordination Scheme for Smart Grid Based Distribution Systems Using Wavelet Based Fault Location and Communication Support
    de Carvalho, R. V. R.
    Vieira, F. H. T.
    de Araujo, S. G.
    Lima, C. R.
    2013 IEEE PES CONFERENCE ON INNOVATIVE SMART GRID TECHNOLOGIES (ISGT LATIN AMERICA), 2013,
  • [10] Wavelet based fault location on power transmission lines using real-world travelling wave data
    Parsi, Mahmood
    Crossley, Peter
    Dragotti, Pier Luigi
    Cole, David
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 186