Robust Active Disturbance Rejection Control for LVRT capability enhancement of DFIG-based wind turbines

被引:26
作者
Beltran-Pulido, Andres [1 ]
Cortes-Romero, John [1 ]
Coral-Enriquez, Horacio [2 ]
机构
[1] Univ Nacl Colombia, Fac Engn, Dept Elect & Elect Engn, Av Cra 30 45-03,Edif 411,Of 203A, Bogota, Colombia
[2] Univ San Buenaventura, Fac Engn, Cra 8H,172-20, Bogota, Colombia
关键词
Wind Turbine (WT); Doubly Fed Induction Generator (DFIG); Low-Voltage Ride-Through (LVRT) capability; Reactive support; Robust Active Disturbance Rejection Control (ADRC); FED INDUCTION GENERATOR; LOW-VOLTAGE-RIDE; ENERGY-STORAGE SYSTEM; THROUGH CAPABILITY; GRID FAULTS; TRACKING CONTROL; CONTROL STRATEGY; POWER; INTEGRATION; DYNAMICS;
D O I
10.1016/j.conengprac.2018.06.001
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article presents the development of a strategy to enhance the Low-Voltage Ride-Through capability (LVRT) of Doubly Fed Induction Generator (DFIG)-based Wind Turbines (WTs). The developed control scheme proposes a trajectory generation system and a high-performance rotor current controller. First, the rotor current trajectories are obtained according to the grid codes requirements. These codes introduce suitable values for the electromagnetic torque and the active and reactive power during operation in normal and fault modes. A detailed analysis of controllability and stability aims to find out how to pair the control inputs and the controlled outputs according to the suggested operation conditions. As a result, a comprehensive study of the required rotor current trajectories to enhance the LVRT capability is developed. Second, the design of the rotor current controller is based on Active Disturbance Rejection Control (ADRC) approach. This controller accomplishes two main objectives: (1) it guarantees a robust tracking of the proposed trajectories, despite uncertainties, disturbances and symmetrical and asymmetrical faults in the grid; and (2) it keeps the rotor voltages and currents in their allowed ratings. Finally, the proposed scheme and the theoretical analysis are validated with simulation studies and laboratory tests.
引用
收藏
页码:174 / 189
页数:16
相关论文
共 51 条
[1]  
Abad G, 2011, DOUBLY FED INDUCTION, P320
[2]  
Abdelrahem M, 2016, INT C COMP ELEC ENG, P70, DOI 10.1109/ICECE.2016.7853858
[3]  
Akhmatov V, 2005, INDUCTION GENERATORS, P258
[4]  
Bianchi F. D, 2007, ADV IND CONTR WIND T, DOI [10.1007/1-84628-493-7., DOI 10.1007/1-84628-493-7.]
[5]  
Coral-Enriquez Horacio, 2016, 2016 IEEE Conference on Control Applications (CCA), P575, DOI 10.1109/CCA.2016.7587891
[6]   Robust Active Disturbance Rejection Control Approach to Maximize Energy Capture in Variable-Speed Wind Turbines [J].
Coral-Enriquez, Horacio ;
Cortes-Romero, John ;
Ramos, German A. .
MATHEMATICAL PROBLEMS IN ENGINEERING, 2013, 2013
[7]   Generalized proportional integral control. for periodic signals under active disturbance rejection approach [J].
Cortes-Romero, John ;
Ramos, German A. ;
Coral-Enriquez, Horacio .
ISA TRANSACTIONS, 2014, 53 (06) :1901-1909
[8]   Robust Controller for DFIGs of Grid-Connected Wind Turbines [J].
da Costa, Jean Patric ;
Pinheiro, Humberto ;
Degner, Thomas ;
Arnold, Gunter .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (09) :4023-4038
[9]  
Gao ZQ, 2001, IEEE DECIS CONTR P, P4578, DOI 10.1109/CDC.2001.980926
[10]  
Gast' O, 2007, IET RENEW POWER GEN, V7, P484