A Flexible and Wearable Human Stress Monitoring Patch

被引:98
作者
Yoon, Sunghyun [1 ]
Sim, Jai Kyoung [1 ]
Cho, Young-Ho [1 ]
机构
[1] Korea Adv Inst Sci & Technol, NanoSentuating Syst Lab, Cell Bench Res Ctr, 271 Daehak Ro, Daejeon 305701, South Korea
关键词
HEART-RATE-VARIABILITY; TACTILE SENSOR; MENTAL STRESS; PRESSURE SENSOR; BLOOD-PRESSURE; PULSE; RESPONSES; DESIGN;
D O I
10.1038/srep23468
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A human stress monitoring patch integrates three sensors of skin temperature, skin conductance, and pulsewave in the size of stamp (25 mm x 15 mm x 72 mu m) in order to enhance wearing comfort with small skin contact area and high flexibility. The skin contact area is minimized through the invention of an integrated multi-layer structure and the associated microfabrication process; thus being reduced to 1/125 of that of the conventional single-layer multiple sensors. The patch flexibility is increased mainly by the development of flexible pulsewave sensor, made of a flexible piezoelectric membrane supported by a perforated polyimide membrane. In the human physiological range, the fabricated stress patch measures skin temperature with the sensitivity of 0.31 Omega/degrees C, skin conductance with the sensitivity of 0.28 mu V/0.02 mu S, and pulse wave with the response time of 70 msec. The skin-attachable stress patch, capable to detect multimodal bio-signals, shows potential for application to wearable emotion monitoring.
引用
收藏
页数:11
相关论文
共 67 条
[1]  
Akhmedov G., 1968, HYDROTECHNICAL CONST, V2, P215
[2]  
[Anonymous], 2014, P 8 INT C PERV COMP, DOI DOI 10.4108/ICST.PERVASIVEHEALTH.2014.254959
[3]  
Ark W., 1999, 8 INT C HUM COMP INT
[4]  
ATTERHOG JH, 1981, BRIT HEART J, V46, P311
[5]  
Brown Lindsay., 2009, Pervasive Computing Technologies for Healthcare, P1
[6]  
Carlson N., 1998, FDN PHYSL PSYCHOL, P459
[7]   ECG-based Mental Stress Assessment Using Fuzzy Computing and Associative Petri Net [J].
Chiang, Hsiu-Sen .
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 35 (06) :833-844
[8]   Review and Reappraisal of Smart Clothing [J].
Cho, Gilsoo ;
Lee, Seungsin ;
Cho, Jayoung .
INTERNATIONAL JOURNAL OF HUMAN-COMPUTER INTERACTION, 2009, 25 (06) :582-617
[9]   Effects of surface morphology on retention loss of ferroelectric domains in poly(vinylidenefluoride-co-trifluoroethylene) thin films [J].
Choi, Hyunwoo ;
Hong, Seungbum ;
Sung, Tae-Hyun ;
No, Kwangsoo .
APPLIED PHYSICS LETTERS, 2011, 99 (09)
[10]   Development and Evaluation of an Ambulatory Stress Monitor Based on Wearable Sensors [J].
Choi, Jongyoon ;
Ahmed, Beena ;
Gutierrez-Osuna, Ricardo .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2012, 16 (02) :279-286