MRI in Patients with Cardiac Implantable Electronic Devices

被引:45
作者
Muthalaly, Rahul G. [1 ,2 ,3 ,4 ]
Nerlekar, Nitesh [1 ,2 ]
Ge, Yin [3 ,4 ]
Kwong, Raymond Y. [3 ,4 ]
Nasis, Arthur [1 ,2 ]
机构
[1] Monash Univ, Monash Cardiovasc Res Ctr, Clayton, Vic, Australia
[2] Monash Hlth, MonashHeart, Clayton, Vic, Australia
[3] Brigham & Womens Hosp, Div Cardiovasc, 75 Francis St, Boston, MA 02115 USA
[4] Harvard Univ, 75 Francis St, Boston, MA 02115 USA
基金
英国医学研究理事会;
关键词
CARDIOVERTER-DEFIBRILLATOR SYSTEM; RESONANCE-IMAGING ENVIRONMENT; NUCLEAR-MAGNETIC-RESONANCE; 1.5; TESLA; PERMANENT PACEMAKERS; IN-VIVO; CLINICAL SAFETY; SCANNING CONDITIONS; RANDOMIZED-TRIAL; RHYTHM DEVICES;
D O I
10.1148/radiol.2018180285
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Indications for MRI have grown considerably in recent years. However, many patients with cardiac implantable electronic devices are denied imaging due to physician misinterpretation of the risks associated with MRI. This review discusses the theoretical basis for the perceived risk by exploring preclinical literature. It then presents a detailed examination of the true rates of adverse events in clinical studies across both MR nonconditional (legacy) and MR conditional devices. Indeed, many of these adverse events are rare, nonexistent, and/or clinically insignificant in the wealth of published data. The authors then address image quality and the constituents of a safety checklist that institutions should consider when performing MRI in patients with a cardiac implantable electronic device. Lastly, the authors conclude with an overview of future directions for advancement in the field. (c) RSNA, 2018.
引用
收藏
页码:281 / 292
页数:12
相关论文
共 86 条
[41]   Force and torque effects of a 1.5-Tesla MRI scanner on cardiac pacemakers and ICDs [J].
Luechinger, R ;
Duru, F ;
Scheidegger, MB ;
Boesiger, P ;
Candinas, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (02) :199-205
[42]   Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 tesla magnetic resonance imaging units: Are reed switches always closed in strong magnetic fields? [J].
Luechinger, R ;
Duru, F ;
Zeijlemaker, VA ;
Scheidegger, MB ;
Boesiger, P ;
Candinas, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (10) :1419-1423
[43]   In vivo heating of pacemaker leads during magnetic resonance imaging [J].
Luechinger, R ;
Zeijlemaker, VA ;
Pedersen, EM ;
Mortensen, P ;
Falk, E ;
Duru, F ;
Candinas, R ;
Boesiger, P .
EUROPEAN HEART JOURNAL, 2005, 26 (04) :376-383
[44]   Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla [J].
Martin, ET ;
Coman, JA ;
Shellock, FG ;
Pulling, CC ;
Fair, R ;
Jenkins, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) :1315-1324
[45]   Complexity of MRI induced heating on metallic leads: Experimental measurements of 374 configurations [J].
Mattei, Eugenio ;
Triventi, Michele ;
Calcagnini, Giovanni ;
Censi, Federica ;
Kainz, Wolfgang ;
Mendoza, Gonzalo ;
Bassen, Howard I. ;
Bartolini, Pietro .
BIOMEDICAL ENGINEERING ONLINE, 2008, 7 (1)
[46]   Electromagnetic interference induced by magnetic resonance imaging [J].
McIntyre, William F. ;
Michael, Kevin A. ;
Baranchuk, Adrian .
CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 (02) :E64-E64
[47]   Cardiac biomarkers in patients with permanent pacemakers and implantable cardioverter-defibrillators undergoing an MRI scan [J].
Mollerus, Michael ;
Albin, Glenn ;
Lipinski, Margaret ;
Lucca, Jill .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (10) :1241-1245
[48]   Magnetic resonance imaging of pacemakers and implantable cardioverter-defibrillators without specific absorption rate restrictions [J].
Mollerus, Michael ;
Albin, Glenn ;
Lipinski, Margaret ;
Lucca, Jill .
EUROPACE, 2010, 12 (07) :947-951
[49]   Ectopy in Patients with Permanent Pacemakers and Implantable Cardioverter-Defibrillators Undergoing an MRI Scan [J].
Mollerus, Michael ;
Albin, Glenn ;
Lipinski, Margaret ;
Lucca, Jill .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (06) :772-778
[50]   Immediate and 12 months follow up of function and lead integrity after cranial MRI in 356 patients with conventional cardiac pacemakers [J].
Muehling, Olaf M. ;
Wakili, Reza ;
Greif, Martin ;
von Ziegler, Franz ;
Morhard, Dominik ;
Brueckmann, Hartmut ;
Becker, Alexander .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16