Effect of window geometry on wind driven single sided ventilation through one opening

被引:19
作者
Albuquerque, Daniel P. [1 ]
O'Sullivan, Paul D. [2 ]
da Graca, Guilherme Carrilho [1 ]
机构
[1] Univ Lisbon, Fac Ciencias, Inst Dom Luiz, Lisbon, Portugal
[2] Cork Inst Technol, Dept Proc Energy & Transport, Rossa Ave, Cork, Ireland
关键词
Natural ventilation; Single-sided ventilation; Ventilation rate; Window geometry; Wind tunnel measurements; Full-scale test chamber; NATURAL VENTILATION; AIR-FLOW; POLLUTANT DISPERSION; CFD SIMULATION; MODEL; FIELD; BUILDINGS; COMFORT; RATES;
D O I
10.1016/j.enbuild.2021.111060
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Natural ventilation (NV) through a single openable window (SS1) is the most common passive cooling strategy for small rooms. SS1 NV driven by wind can be propelled by pressure variations along the opening or, in medium and large buildings, wind driven shear. This paper presents an experimental study of the impact of typical window geometries on SS1 NV flows driven by wind shear parallel to the building fa & ccedil;ade. The experiments were performed in two complementary setups, a wind tunnel test of a reduced scale SS1 and a full-scale SS1 room subjected to artificial wind shear that was equipped with eight different windows. Results show that the combination between window geometry and wind direction has a large impact on SS1 ventilation. For the same window area, results show that in combinations where the window directs the wind flow towards the room, the flow is up to four times larger. In contrast, when the combination is unfavorable, the window reduces the wind driven SS1 flow by up to 23%. This study identified the best window configurations for wind driven SS1 in dense urban environments. By combining average results for measured wind velocities in street canyons with the flow coefficients for typical window geometries, it was possible to propose simple correlations for wind driven SS1 in urban environments that more precise than existing models. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:15
相关论文
共 60 条
[1]   Full-scale measurement and validated simulation of cooling load reduction due to nighttime natural ventilation of a large atrium [J].
Albuquerque, Daniel P. ;
Mateus, Nuno ;
Avantaggiato, Marta ;
da Graca, Guilherme Carrilho .
ENERGY AND BUILDINGS, 2020, 224
[2]   Experimental and numerical investigation of pumping ventilation on the leeward side of a cubic building [J].
Albuquerque, Daniel P. ;
Sandberg, Mats ;
Linden, P. F. ;
da Graca, Guilherme Carrilho .
BUILDING AND ENVIRONMENT, 2020, 179
[3]   Design analysis of single-sided natural ventilation [J].
Allocca, C ;
Chen, QY ;
Glicksman, LR .
ENERGY AND BUILDINGS, 2003, 35 (08) :785-795
[4]  
[Anonymous], 2004, BUILDING SERV ENG RE, DOI DOI 10.1191/0143624404BT107OA
[5]  
[Anonymous], 2015, P BS2015 14 C INT BU
[6]   Single-sided ventilation of buildings through shaded large openings [J].
Argiriou, AA ;
Balaras, CA ;
Lykoudis, SP .
ENERGY, 2002, 27 (02) :93-115
[7]  
Baik JJ, 2000, J APPL METEOROL, V39, P1592, DOI 10.1175/1520-0450(2000)039<1592:ALMOUS>2.0.CO
[8]  
2
[9]   Pedestrian-level wind conditions around buildings: Review of wind-tunnel and CFD techniques and their accuracy for wind comfort assessment [J].
Blocken, B. ;
Stathopoulos, T. ;
van Beeck, J. P. A. J. .
BUILDING AND ENVIRONMENT, 2016, 100 :50-81
[10]   CFD simulation for pedestrian wind comfort and wind safety in urban areas: General decision framework and case study for the Eindhoven University campus [J].
Blocken, B. ;
Janssen, W. D. ;
van Hooff, T. .