The efficacy of a low-dose, monodisperse parasympathicolytic aerosol compared with a standard aerosol from a metered-dose inhaler

被引:23
作者
Zanen, P [1 ]
Go, LT [1 ]
Lammers, JWJ [1 ]
机构
[1] Univ Utrecht Hosp, Dept Pulm Dis, NL-3508 GA Utrecht, Netherlands
关键词
aerosols; ipratropium bromide;
D O I
10.1007/s002280050415
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objective: In previous experiments we showed that monodisperse bronchodilator aerosols with a median mass aerodynamic diameter of 2.8 mu m induced stronger bronchodilatations than larger aerosols and that the dilatations were clinically relevant at low doses. To discover whether the bronchodilator effects of these low-dose monodisperse aerosols differed from those of standard dosages delivered by metered-dose inhalers, we carried out a comparative trial. Methods: Ten stable outpatients with a mean forced expiratory volume in 1 s (FEV1) of 58.1% of the predicted value inhaled a placebo aerosol, 8 mu g of a 2.8-mu m monodisperse ipratropium bromide aerosol and 40 mu g from a metered-dose inhaler plus spacer; lung-function measurements followed. Data were analysed with repeated measurements analysis of variance (ANOVA). Results: Greater improvements than with placebo were evident for the forced vital capacity (FVC), the FEV1, the specific airway conductance (sGaw), the peak flow (PEF) and the maximum expiratory flow at 75% of the forced vital capacity (MEF75). In these cases, the low-dose 2.8-mu m aerosol proved to be equivalent to the higher-dose metered-dose inhaler. Conclusion: By changing the polydisperse characteristic of inhaled aerosols to a monodisperse pattern, the dose of the drug administered can be reduced without loss of efficacy.
引用
收藏
页码:27 / 30
页数:4
相关论文
共 15 条
  • [1] Inhalational drug delivery from seven different spacer devices
    Barry, PW
    OCallaghan, C
    [J]. THORAX, 1996, 51 (08) : 835 - 840
  • [2] BOUCHIKHI A, 1988, EUR RESPIR J, V1, P547
  • [3] DOSE RELATED EFFECTS OF SALBUTAMOL AND IPRATROPIUM BROMIDE ON AIRWAY CALIBER AND REACTIVITY IN SUBJECTS WITH ASTHMA
    BRITTON, J
    HANLEY, SP
    GARRETT, HV
    HADFIELD, JW
    TATTERSFIELD, AE
    [J]. THORAX, 1988, 43 (04) : 300 - 305
  • [4] THE SPINNING-TOP AEROSOL GENERATOR - IMPROVING THE PERFORMANCE
    CHEAH, PKP
    DAVIES, CN
    [J]. JOURNAL OF AEROSOL SCIENCE, 1984, 15 (06) : 741 - &
  • [5] SPIROMETRY IN THE LUNG HEALTH STUDY .1. METHODS AND QUALITY-CONTROL
    ENRIGHT, PL
    JOHNSON, LR
    CONNETT, JE
    VOELKER, H
    BUIST, AS
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (06): : 1215 - 1223
  • [6] Girden E.R., 1992, ANOVA REPEATED MEASU, V84
  • [7] HILLER C, 1978, AM REV RESPIR DIS, V118, P311
  • [9] NEWMAN P, 1992, ASTHMA, P469
  • [10] Inhalation of single vs multiple metered-dose bronchodilator actuations from reservoir devices - An in vitro study
    Rau, JL
    Restrepo, RD
    Deshpande, V
    [J]. CHEST, 1996, 109 (04) : 969 - 974