A combined power and ejector refrigeration cycle for low temperature heat sources

被引:115
作者
Zheng, B. [1 ]
Weng, Y. W. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Combined power and refrigeration; Organic Rankine cycle; Ejector refrigeration cycle; Low temperature heat sources; COOLING THERMODYNAMIC CYCLE; ORGANIC RANKINE-CYCLE; WORKING FLUIDS; RECOVERY; SYSTEMS;
D O I
10.1016/j.solener.2010.02.001
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A combined power and ejector refrigeration cycle for low temperature heat sources is under investigation in this paper. The proposed cycle combines the organic Rankine cycle and the ejector refrigeration cycle. The ejector is driven by the exhausts from the turbine to produce power and refrigeration simultaneously. A simulation was carried out to analyze the cycle performance using R245fa as the working fluid. A thermal efficiency of 34.1%, an effective efficiency of 18.7% and an exergy efficiency of 56.8% can be obtained at a generating temperature of 395 K, a condensing temperature of 298 K and an evaporating temperature of 280 K. Simulation results show that the proposed cycle has a big potential to produce refrigeration and most exergy losses take place in the ejector. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:784 / 791
页数:8
相关论文
共 18 条
[1]   Ejector irreversibility characteristics [J].
Arbel, A ;
Shklyar, A ;
Hershgal, D ;
Barak, M ;
Sokolov, M .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (01) :121-129
[2]  
Goswami D.Y., 1995, Proc. of the 2nd ISHMT-ASME Heat and Mass Trans. Conf, P57
[3]   Analysis of a new thermodynamic cycle for combined power and cooling using low and mid temperature solar collectors [J].
Goswami, DY ;
Xu, F .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (02) :91-97
[4]   First and second law analysis of a new power and refrigeration thermodynamic cycle using a solar heat source [J].
Hasan, AA ;
Goswami, DY ;
Vijayaraghavan, S .
SOLAR ENERGY, 2002, 73 (05) :385-393
[5]   A 1-D analysis of ejector performance [J].
Huang, BJ ;
Chang, JM ;
Wang, CP ;
Petrenko, VA .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (05) :354-364
[6]   Waste heat recovery of organic Rankine cycle using dry fluids [J].
Hung, TC .
ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (05) :539-553
[7]   Effect of working fluids on organic Rankine cycle for waste heat recovery [J].
Liu, BT ;
Chien, KH ;
Wang, CC .
ENERGY, 2004, 29 (08) :1207-1217
[8]   Unconventional working fluids in organic Rankine-cycles for waste energy recovery systems [J].
Maizza, V ;
Maizza, A .
APPLIED THERMAL ENGINEERING, 2001, 21 (03) :381-390
[9]   Effectiveness of cooling production with a combined power and cooling thermodynamic cycle [J].
Martin, C ;
Goswami, DY .
APPLIED THERMAL ENGINEERING, 2006, 26 (5-6) :576-582
[10]   Analysis of heat-driven jet-pumped cooling system for space thermal management [J].
Nord, JW ;
Lear, WE ;
Sherif, SA .
JOURNAL OF PROPULSION AND POWER, 2001, 17 (03) :566-570