Hollow Fiber Membrane Contactors for Post-Combustion CO2 Capture: A Scale-Up Study from Laboratory to Pilot Plant

被引:24
作者
Chabanon, E. [1 ]
Kimball, E. [2 ]
Favre, E. [1 ]
Lorain, O. [3 ]
Goetheer, E. [2 ]
Ferre, D. [4 ]
Gomez, A. [4 ]
Broutin, P. [4 ]
机构
[1] LRGP UPR CNRS 3349, Lab React & Genie Proc, F-54000 Nancy, France
[2] TNO, NL-2628 CA Delft, Netherlands
[3] Polymem, F-31100 Toulouse, France
[4] IFP Energies Nouvelles, F-69360 Solaize, France
来源
OIL AND GAS SCIENCE AND TECHNOLOGY-REVUE D IFP ENERGIES NOUVELLES | 2014年 / 69卷 / 06期
关键词
TYPICAL AMINE SOLUTIONS; MASS-TRANSFER; GAS-ABSORPTION; REMOVAL; PERFORMANCE; MODEL;
D O I
10.2516/ogst/2012046
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Membrane contactors have been proposed for decades as a way to achieve intensified mass transfer processes. Post-combustion CO2 capture by absorption into a chemical solvent is one of the currently most intensively investigated topics in this area. Numerous studies have already been reported, unfortunately almost systematically on small, laboratory scale, modules. Given the level of flue gas flow rates which have to be treated for carbon capture applications, a consistent scale-up methodology is obviously needed for a rigorous engineering design. In this study, the possibilities and limitations of scale-up strategies for membrane contactors have been explored and will be discussed. Experiments (CO2 absorption from a gas mixture in a 30% wt MEA aqueous solution) have been performed both on mini-modules and at pilot-scale (10 m(2) membrane contactor module) based on PTFE hollow fibers. The results have been modeled utilizing a resistance in series approach. The only adjustable parameter is in fitting the simulations to experimental data is the membrane mass transfer coefficient (k(m)), which logically plays a key role. The difficulties and uncertainties associated with scale-up computations from lab scale to pilot-scale modules, with a particular emphasis on the k(m) value, are presented and critically discussed.
引用
收藏
页码:1035 / 1045
页数:11
相关论文
共 38 条
[1]   CO2 capture from power plants -: Part II.: A parametric study of the economical performance based on mono-ethanolamine [J].
Abu-Zahra, Mohammad R. M. ;
Niederer, John P. M. ;
Feron, Paul H. M. ;
Versteeg, Geert F. .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2007, 1 (02) :135-142
[2]   Modeling of CO2 absorption in membrane contactors [J].
Al-Marzouqi, Mohamed H. ;
El-Naas, Muftah H. ;
Marzouk, Sayed A. M. ;
Al-Zarooni, Mohamed A. ;
Abdullatif, Nadia ;
Faiz, Rami .
SEPARATION AND PURIFICATION TECHNOLOGY, 2008, 59 (03) :286-293
[3]  
BLAUWHOFF PMM, 1984, CHEM ENG SCI, V39, P207, DOI 10.1016/0009-2509(84)80021-4
[4]   A modeling study on the effects of membrane characteristics and operating parameters on physical absorption of CO2 by hollow fiber membrane contactor [J].
Boributh, Somnuk ;
Assabumrungrat, Suttichai ;
Laosiripojana, Navadol ;
Jiraratananon, Ratana .
JOURNAL OF MEMBRANE SCIENCE, 2011, 380 (1-2) :21-33
[5]   CO2 removal from a gas stream by membrane contactor [J].
Bottino, Aldo ;
Capannelli, Gustavo ;
Comite, Antonio ;
Di Felice, Renzo ;
Firpo, Raffaella .
SEPARATION AND PURIFICATION TECHNOLOGY, 2008, 59 (01) :85-90
[6]   Hollow fiber membrane contactor for hydrogen sulfide odor control [J].
Bouci, Noureddine ;
Favre, Eric ;
Roizard, Denis ;
Belloul, Mohamed .
AICHE JOURNAL, 2008, 54 (01) :122-131
[7]   CO2 capture in HFMM contactor with typical amine solutions: A numerical analysis [J].
Boucif, Noureddine ;
Favre, Eric ;
Roizard, Denis .
CHEMICAL ENGINEERING SCIENCE, 2008, 63 (22) :5375-5385
[8]   Chemical absorption of carbon dioxide with asymmetrically heated polytetrafluoroethylene membranes [J].
Chen, Shia-Chung ;
Lin, Su-Hsia ;
Chien, Rean-Der ;
Wang, Yuen-Hua ;
Hsiao, Hseun-Chi .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2011, 92 (04) :1083-1090
[9]   Using polypropylene and polytetrafluoroethylene membranes in a membrane contactor for CO2 absorption [J].
deMontigny, David ;
Tontiwachwuthikul, Paitoon ;
Chakma, Amit .
JOURNAL OF MEMBRANE SCIENCE, 2006, 277 (1-2) :99-107
[10]   Hollow fiber membrane contactor as a gas-liquid model contactor [J].
Dindore, VY ;
Brilman, DWF ;
Versteeg, GE .
CHEMICAL ENGINEERING SCIENCE, 2005, 60 (02) :467-479