Non-contrast-enhanced imaging of haemodialysis fistulas using quiescent-interval single-shot (QISS) MRA: a feasibility study

被引:7
作者
Okur, A. [1 ]
Kantarci, M. [2 ]
Karaca, L. [2 ]
Yildiz, S. [3 ]
Sade, R. [2 ]
Pirimoglu, B. [2 ]
Keles, M. [4 ]
Avci, A. [5 ]
Cankaya, E. [4 ]
Schmitt, P. [6 ]
机构
[1] Bozok Univ, Sch Med, Dept Radiol, Yozgat, Turkey
[2] Ataturk Univ, Sch Med, Dept Radiol, Erzurum, Turkey
[3] Harran Univ, Sch Med, Dept Radiol, Sanliurfa, Turkey
[4] Ataturk Univ, Sch Med, Dept Internal Med, Div Nephrol, Erzurum, Turkey
[5] Siemens Turkey, Istanbul, Turkey
[6] Siemens AG, MR Applicat & Workflow Dev, Healthcare Sect, Erlangen, Germany
关键词
MAGNETIC-RESONANCE ANGIOGRAPHY; DISTAL LOWER-EXTREMITIES; PERIPHERAL ARTERIAL-DISEASE; CHRONIC KIDNEY-DISEASE; VASCULAR ACCESS;
D O I
10.1016/j.crad.2015.11.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To assess the efficiency of a novel quiescent-interval single-shot (QISS) technique for non-contrast-enhanced magnetic resonance angiography (MRA) of haemodialysis fistulas. MATERIALS AND METHODS: QISS MRA and colour Doppler ultrasound (CDU) images were obtained from 22 haemodialysis patients with end-stage renal disease (ESRD). A radiologist with extensive experience in vascular imaging initially assessed the fistulas using CDU. Two observers analysed each QISS MRA data set in terms of image quality, using a five-point scale ranging from 0 (non-diagnostic) to 4 (excellent), and lumen diameters of all segments were measured. RESULTS: One hundred vascular segments were analysed for QISS MRA. Two anastomosis segments were considered non-diagnostic. None of the arterial or venous segments were evaluated as non-diagnostic. The image quality was poorer for the anastomosis level compared to the other segments (p<0.001 for arterial segments, and p<0.05 for venous segments), while no significant difference was determined for other vascular segments. CONCLUSION: QISS MRA has the potential to provide valuable complementary information to CDU regarding the imaging of haemodialysis fistulas. In addition, QISS non-enhanced MRA represents an alternative for assessment of haemodialysis fistulas, in which the administration of iodinated or gadolinium-based contrast agents is contraindicated. (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:244 / 249
页数:6
相关论文
共 24 条
[21]   Initial Clinical Evaluation of a Non-Contrast-Enhanced MR Angiography Method in the Distal Lower Extremities [J].
Priest, Andrew Nicholas ;
Joubert, Ilse ;
Winterbottom, Andrew Philip ;
See, Teik Choon ;
Graves, Martin John ;
Lomas, David John .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) :1644-1652
[22]   Incidence of nephrogenic systemic fibrosis at two large medical centers [J].
Prince, Martin R. ;
Zhang, Honglei ;
Morris, Michael ;
MacGregor, Jennifer L. ;
Grossman, Marc E. ;
Silberzweig, Jeffrey ;
DeLapaz, Robert L. ;
Lee, Henry J. ;
Magro, Cynthia M. ;
Valeri, Anthony M. .
RADIOLOGY, 2008, 248 (03) :807-816
[23]   Magnetic resonance angiography of dialysis access shunts: Initial results [J].
Waldman, GJ ;
Pattynama, PMT ;
Chang, PC ;
Verburgh, C ;
Reiber, JHC ;
deRoos, A .
MAGNETIC RESONANCE IMAGING, 1996, 14 (02) :197-200
[24]   Comparison of Quiescent Inflow Single-Shot and Native Space for Nonenhanced Peripheral MR Angiography [J].
Ward, Emily V. ;
Galizia, Mauricio S. ;
Usman, Asad ;
Popescu, Andrada R. ;
Dunkle, Eugene ;
Edelman, Robert R. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (06) :1531-1538