Hepatic Steatosis in Chronic Hepatitis B as Measured by Controlled Attenuation Parameter: Frequency and Distribution

被引:1
|
作者
Nan, Shiying [1 ]
Liang, Yan [2 ]
Qu, Yundong [1 ]
Liu, Feng [1 ]
Wang, Lei [1 ]
Li, Tao [1 ]
机构
[1] Shandong Univ, Hosp 2, Dept Infect Dis & Hepatol, 247 Beiyuan Rd, Jinan 250033, Shandong, Peoples R China
[2] Jinan Infect Dis Hosp, Dept Hepatol, Jinan, Shandong, Peoples R China
来源
JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN | 2019年 / 29卷 / 10期
关键词
Chronic hepatitis B; Liver steatosis; Liver fibrosis; Controlled attenuation parameter; FATTY LIVER-DISEASE; PREVALENCE; ASSOCIATION; FIBROSIS;
D O I
10.29271/jcpsp.2019.10.937
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To determine the frequency of liver steatosis in chronic hepatitis B (CHB) patients measured by controlled attenuation parameter (CAP) and to describe the distribution of fibrosis and inflammation in different steatosis grading. Study Design: Cross-sectional study. Place and Duration of Study: Department of Infectious Diseases and Hepatology, The Second Hospital of Shandong University, Jinan, China, from January 2017 to December 2018. Methodology: CHB patients who were evaluated with transient elastography (TE) for liver fibrosis and steatosis were included. Liver biochemical testing was performed within 3 days of TE measurements. Steatosis grading was assessed as SO (no steatosis, CAP 0-247 dB/m), 51 (mild steatosis, CAP 248-267 dB/m), S2 (moderate steatosis, CAP 268-279 dB/m) and S3 (severe steatosis, CAP >=280 dB/m). Statistically comparisons of continuous variables or percentages were performed. Results: A total of 1,621 CHB patients were included. The frequencies of liver steatosis in CHB patients were 35.4% (574 patients), of which 314 patients (19.3%) were diagnosed as severe steatosis (grading S3). Comparisons of age, gender and liver fibrosis in different steatosis grading revealed no statistical differences (p=0.109, 0.075 and 0.269, respectively). However, ALT values in patients with severe steatosis (grading S3) were higher than those patients with steatosis grading S0 (p<0.001) and S2 (p=0.047). Conclusion: Steatosis is common in CHB patients. Liver fibrosis seemed not discrepant in different steatosis grading. More obvious hepatic inflammation is seen in CHB patients with severe steatosis.
引用
收藏
页码:937 / 941
页数:5
相关论文
共 50 条
  • [1] Association Between Hepatic Steatosis, Measured by Controlled Attenuation Parameter, and Fibrosis Burden in Chronic Hepatitis B
    Seto, Wai-Kay
    Hui, Rex W. H.
    Mak, Lung-Yi
    Fung, James
    Cheung, Ka-Shing
    Liu, Kevin S. H.
    Wong, Danny Ka-Ho
    Lai, Ching-Lung
    Yuen, Man-Fung
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2018, 16 (04) : 575 - +
  • [2] Controlled attenuation parameter for the detection of hepatic steatosis in patients with chronic hepatitis B
    Chen, Jing
    Wu, Dongbo
    Wang, Menglan
    Chen, Enqiang
    Bai, Lang
    Liu, Cong
    Liao, Juan
    Tang, Hong
    INFECTIOUS DISEASES, 2016, 48 (09) : 670 - 675
  • [3] Diagnostic value of controlled attenuation parameter for liver steatosis in patients with chronic hepatitis B
    Wang, Chun-Yan
    Lu, Wei
    Hu, Dong-Sheng
    Wang, Guang-Dong
    Cheng, Xiao-Jing
    WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (30) : 10585 - 10590
  • [4] Controlled Attenuation Parameter for Noninvasive Assessment of Hepatic Steatosis Using Fibroscan®: Validation in Chronic Hepatitis B
    Mi, Yu-Qiang
    Shi, Qi-Yu
    Xu, Liang
    Shi, Rui-Fang
    Liu, Yong-Gang
    Li, Ping
    Shen, Feng
    Lu, Wei
    Fan, Jian-Gao
    DIGESTIVE DISEASES AND SCIENCES, 2015, 60 (01) : 243 - 251
  • [5] Effects of hepatic fibrosis on the quantification of hepatic steatosis using the controlled attenuation parameter in patients with chronic hepatitis B
    Park, Hee Jun
    Kang, Hyo Jeong
    Kim, So Yeon
    Yoon, Seonghun
    Baek, Seunghee
    Song, In Hye
    Jang, Hyeon Ji
    Jang, Jong Keon
    ULTRASONOGRAPHY, 2025, 44 (01) : 83 - 91
  • [6] A comparison of hepatic steatosis index, controlled attenuation parameter and ultrasound as noninvasive diagnostic tools for steatosis in chronic hepatitis B
    Xu, Liang
    Lu, Wei
    Li, Ping
    Shen, Feng
    Mi, Yu-Qiang
    Fan, Jian-Gao
    DIGESTIVE AND LIVER DISEASE, 2017, 49 (08) : 910 - 917
  • [7] Diagnostic value of controlled attenuation parameter for liver steatosis in patients with chronic hepatitis B
    Chun-Yan Wang
    Wei Lu
    Dong-Sheng Hu
    Guang-Dong Wang
    Xiao-Jing Cheng
    World Journal of Gastroenterology, 2014, (30) : 10585 - 10590
  • [8] The relationship between visceral obesity and hepatic steatosis measured by controlled attenuation parameter
    Lee, Hye Won
    Kim, Kwang Joon
    Jung, Kyu Sik
    Chon, Young Eun
    Huh, Ji Hye
    Park, Kyeong Hye
    Chung, Jae Bock
    Kim, Chang Oh
    Han, Kwang-Hyub
    Park, Jun Yong
    PLOS ONE, 2017, 12 (10):
  • [9] Controlled attenuation parameter for evaluating liver steatosis in chronic viral hepatitis
    Ferraioli, Giovanna
    Tinelli, Carmine
    Lissandrin, Raffaella
    Zicchetti, Mabel
    Dal Bello, Barbara
    Filice, Gaetano
    Filice, Carlo
    WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (21) : 6626 - 6631
  • [10] Controlled Attenuation Parameter for Noninvasive Assessment of Hepatic Steatosis Using Fibroscan®: Validation in Chronic Hepatitis B
    Yu-Qiang Mi
    Qi-Yu Shi
    Liang Xu
    Rui-Fang Shi
    Yong-Gang Liu
    Ping Li
    Feng Shen
    Wei Lu
    Jian-Gao Fan
    Digestive Diseases and Sciences, 2015, 60 : 243 - 251