Purpose: Four-dimensional cone-beam computed tomography (4D-CBCT) imaging is sensitive to parameters such as gantry rotation speed, number of gantry rotations, X-ray pulse rate, and tube current, as well as a patient's breathing pattern. The aim of this study is to optimize the image acquisition on a patient-specific basis while minimizing the scan time and the radiation dose. Methods and Materials: More than 60 sets of 4D-CBCT images, each with a temporal resolution of 10 phases, were acquired using multiple-gantry rotation and slow-gantry rotation techniques. The image quality was quantified with a relative root mean-square error (RE) and correlated with various acquisition settings; specitically, varying gantry rotation speed, varying both the rotation speed and the number of rotations, and varying both the rotation speed and tube current to keep the radiation exposure constant. These experiments were repeated for three different respiratory periods. Results: With similar radiation dose, 4D-CBCT images acquired with low current and low rotation speed have better quality over images obtained with high current and high rotation speed. In general, a one-rotation low-speed scan is superior to a two-rotation double-speed scan, even though they provide the same number of projections. Furthermore, it is found that the image quality behaves monotonically with the relative speed as defined by the gantry rotation speed and the patient respiratory period. Conclusions: The RE curves established in this work can be used to predict the 4D-CBCT image quality before a scan. This allows the acquisition protocol to be optimized individually to balance the desired quality with the associated scanning time and patient radiation dose. (c) 2007 Elsevier Inc.
引用
收藏
页码:1211 / 1219
页数:9
相关论文
共 33 条
  • [1] Automated generation of a four-dimensional model of the liver using warping and mutual information
    Brock, KM
    Balter, JM
    Dawson, LA
    Kessler, ML
    Meyer, CR
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1128 - 1133
  • [2] Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines
    Coselmon, MM
    Balter, JM
    McShan, DL
    Kessler, ML
    [J]. MEDICAL PHYSICS, 2004, 31 (11) : 2942 - 2948
  • [3] RECONSTRUCTION OF 3 DIMENSIONAL STRUCTURE FROM PROJECTIONS AND ITS APPLICATION TO ELECTRON MICROSCOPY
    CROWTHER, RA
    DEROSIER, DJ
    KLUG, A
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1970, 317 (1530): : 319 - &
  • [4] Flat-panel cone-beam computed tomography for image-guided radiation therapy
    Jaffray, DA
    Siewerdsen, JH
    Wong, JW
    Martinez, AA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05): : 1337 - 1349
  • [5] The use of megavoltage CT (MVCT) images for dose recomputations
    Langen, KM
    Meeks, SL
    Poole, DO
    Wagner, TH
    Willoughby, TR
    Kupelian, PA
    Ruchala, KJ
    Haimerl, J
    Olivera, GH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (18) : 4259 - 4276
  • [6] Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients
    Létourneau, D
    Martinez, AA
    Lockman, D
    Yan, D
    Vargas, C
    Ivaldi, G
    Wong, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04): : 1239 - 1246
  • [7] Motion correction for improved target localization with on-board cone-beam computed tomography
    Li, T
    Schreibmann, E
    Yang, Y
    Xing, L
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (02) : 253 - 267
  • [8] Radiation dose reduction in four-dimensional computed tomography
    Li, T
    Schreibmann, E
    Thorndyke, B
    Tillman, G
    Boyer, A
    Koong, A
    Goodman, K
    Xing, L
    [J]. MEDICAL PHYSICS, 2005, 32 (12) : 3650 - 3660
  • [9] LI T, IN PRESS PHYS MED BI
  • [10] Four-dimensional cone-beam computed tomography using an on-board imager
    Li, Tianfang
    Xing, Lei
    Munro, Peter
    McGuinness, Christopher
    Chao, Ming
    Yang, Yong
    Loo, Bill
    Koong, Albert
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3825 - 3833