Assessing Body Composition in Healthy Newborn Infants: Reliability of Dual-Energy X-Ray Absorptiometry

被引:49
作者
Godang, Kristin [1 ]
Qvigstad, Elisabeth
Voldner, Nanna [2 ]
Isaksen, Gunhild A.
Froslie, Kathrine F. [2 ,3 ,4 ]
Notthellen, Jacob [5 ]
Henriksen, Tore [2 ]
Bollerslev, Jens
机构
[1] Natl Hosp Norway, Endocrinol Sect, Oslo Univ Hosp, Dept Endocrinol, N-0027 Oslo, Norway
[2] Natl Hosp Norway, Dept Obstet & Gynecol, Oslo Univ Hosp, N-0027 Oslo, Norway
[3] Natl Hosp Norway, Natl Resource Ctr Womens Hlth, Oslo Univ Hosp, N-0027 Oslo, Norway
[4] Univ Oslo, Inst Basic Med Sci, Dept Biostat, Oslo, Norway
[5] Natl Hosp Norway, Dept Med Phys, Oslo Univ Hosp, N-0027 Oslo, Norway
关键词
Body composition; caliper; DXA; infants; reliability; BONE-MINERAL MEASUREMENTS; SOFT-TISSUE COMPOSITION; SKINFOLD THICKNESS MEASUREMENTS; PHOTON-ABSORPTIOMETRY; TECHNICAL CONSIDERATIONS; PREMATURE-INFANTS; FAT MEASUREMENTS; LUMBAR SPINE; VALIDATION; DENSITOMETRY;
D O I
10.1016/j.jocd.2010.01.121
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dual-energy X-ray absorptiometry (DXA) is used to measure body composition in newborns; however, data on DXA accuracy are limited. We investigated the reliability of body composition measurements by DXA. The present study included 207 normal-term newborn babies, recruited from a larger study on the determinants of birth weight in healthy pregnancies (STORK) between 2005 and 2008. Reliability analysis of total fat mass (FM(DxA)), fat-free mass, lean mass (LM(DxA)), bone mineral content (BMC), and bone mineral density (BMD) were based on 2 DXA scans of 50 neonates. We also performed a comparison analysis for DXA (FM(DxA)) measurements and caliper (CLP) or circumference (CF) measurements of trunk and extremities (performed on all neonates, n = 207). Reliability: All intraclass correlation coefficients (ICC) were satisfactory to excellent for total body and the extremity-compartment FM(DxA), LM(DxA), BMD, and BMC; ICC ranged from 0.86 to 0.96 but with a lower ICC for trunk FM(DxA). For comparison analysis, the Pearson correlation coefficients for CLP vs DXA and CF vs DXA ranged from 0.48 to 0.79 and 0.41 to 0.77, respectively. Quadriceps CLP and CF measurements correlated best with the most reliable DXA results, whereas more modest correlations were found for the trunk region. DXA measurements of body composition demonstrated good reliability and can be used as a reference method in neonates. CLP and CF measurements are appropriate for larger cohorts or when DXA is unavailable, and they provide fair rough estimations of fat mass.
引用
收藏
页码:151 / 160
页数:10
相关论文
共 52 条
[1]  
[Anonymous], BIOMETRICS
[2]   Precision assessment and radiation safety for dual-energy X-ray absorptiometry [J].
Baim, S ;
Wilson, CR ;
Lewiecki, EM ;
Luckey, MM ;
Downs, RW ;
Lentle, BC .
JOURNAL OF CLINICAL DENSITOMETRY, 2005, 8 (04) :371-378
[3]   VARIABILITY OF ABDOMINAL CIRCUMFERENCE OF PREMATURE-INFANTS [J].
BHATIA, P ;
JOHNSON, KJ ;
BELL, EF .
JOURNAL OF PEDIATRIC SURGERY, 1990, 25 (05) :543-544
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
Braillon PM, 2002, J RADIOL, V83, P627
[6]  
BRANSON RS, 1982, HUM BIOL, V54, P137
[7]   Improvement in the accuracy of dual energy X-ray absorptiometry for whole body and regional analysis of body composition: Validation using piglets and methodologic considerations in infants [J].
Brunton, JA ;
Weiler, HA ;
Atkinson, SA .
PEDIATRIC RESEARCH, 1997, 41 (04) :590-596
[8]  
BRUNTON JA, 1993, HUMAN BODY COMPOSITI, V60, P157
[9]  
CHAN GM, 1992, J BONE MINER RES, V7, P369
[10]   ASSESSMENT OF TOTAL-BODY FAT IN INFANCY FROM SKINFOLD THICKNESS MEASUREMENTS [J].
DAUNCEY, MJ ;
GANDY, G ;
GAIRDNER, D .
ARCHIVES OF DISEASE IN CHILDHOOD, 1977, 52 (03) :223-227