An experimental study on even frosting performance of an air source heat pump unit with a multi-circuit outdoor coil

被引:71
作者
Song Mengjie [1 ,2 ]
Xia Liang [3 ]
Mao Ning [4 ]
Deng Shiming [2 ]
机构
[1] Guangdong Univ Technol, Sch Mat & Energy, Guangdong Prov Key Lab Funct Soft Condensed Matte, Guangzhou, Guangdong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
[3] Univ Nottingham Ningbo China, Fac Sci & Engn, Dept Bldg Serv Engn & Bldg Phys, Ningbo, Zhejiang, Peoples R China
[4] China Univ Petr East China, Coll Pipeline & Civil Engn, Qingdao, Shandong, Peoples R China
关键词
Air source heat pump; Multi-circuit outdoor coil; Even frosting; Frosting evenness value; Experiment; HOT-GAS BYPASS; DEFROSTING PERFORMANCE; MELTED FROST; LIQUID DESICCANT; PART I; EXCHANGERS; SYSTEM; FLOW;
D O I
10.1016/j.apenergy.2015.11.036
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
When the surface temperature of the outdoor coil in an air source heat pump (ASHP) unit is lower than both the air dew point and freezing point of water, frost can be formed and accumulated over outdoor coil's surface. On the other hand, an outdoor coil normally has multiple parallel circuits on its refrigerant side for minimized refrigerant pressure loss and enhanced heat transfer efficiency. Currently, most attentions were paid to the experimental and numerical studies on defrosting with different methods, without however paying attention to the distribution of frost accumulation on the multi-circuit outdoor coil. The phenomenon of uneven frosting exists, which also maybe the most important reason of uneven defrosting for an ASHP unit with a multi-circuit outdoor coil. Therefore, in this study, a comparative and experimental study on system frosting performance when frost accumulated on a three-circuit outdoor coil's surface in an ASHP unit at different frosting evenness values (FEVs) has been carried out. Experimental results indicated that, when the FEV was increased from 75.7% to 90.5% for an ASHP unit with a three circuit outdoor coil, the COP could be increased from 4.10 to 4.26 at a 3600 s frosting process, and increased from 3.18 to 4.00 at its last 600 s. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:36 / 44
页数:9
相关论文
共 40 条
  • [1] Heating performance characteristics of a dual source heat pump using air and waste heat in electric vehicles
    Ahn, Jae Hwan
    Kang, Hoon
    Lee, Ho Seong
    Jung, Hae Won
    Baek, Changhyun
    Kim, Yongchan
    [J]. APPLIED ENERGY, 2014, 119 : 1 - 9
  • [2] EXPERIMENTAL-STUDY OF WARM-AIR DEFROSTING OF HEAT-PUMP EVAPORATORS
    AMEEN, FR
    CONEY, JER
    SHEPPARD, CGW
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1993, 16 (01): : 13 - 18
  • [3] [Anonymous], 1983, Int. J. Refrig, DOI DOI 10.1016/0140-7007(83)90095-6
  • [4] Thermal analysis of the defrost cycle in a domestic freezer
    Bansal, Pradeep
    Fothergill, David
    Fernandes, Ryan
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (03): : 589 - 599
  • [5] The application of photo-coupler for frost detecting in an air-source heat pump
    Byun, JS
    Jeon, CD
    Jung, JH
    Lee, J
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (02): : 191 - 198
  • [6] Frost retardation of an air-source heat pump by the hot gas bypass method
    Byun, Ju-Suk
    Lee, Jinho
    Jeon, Chang-Duk
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (02): : 328 - 334
  • [7] Defrosting method adopting dual hot gas bypass for an air-to-air heat pump
    Choi, Hwan-Jong
    Kim, Byung-Soon
    Kang, Donghoon
    Kim, Kyung Chun
    [J]. APPLIED ENERGY, 2011, 88 (12) : 4544 - 4555
  • [8] Effect of fin types of outdoor fan-supplied finned-tube heat exchanger on periodic frosting and defrosting performance of a residential air-source heat pump
    Huang, Dong
    Zhao, Ri-Jing
    Liu, Yun
    Yi, De-Bo
    [J]. APPLIED THERMAL ENGINEERING, 2014, 69 (1-2) : 251 - 260
  • [9] Comparison between hot-gas bypass defrosting and reverse-cycle defrosting methods on an air-to-water heat pump
    Huang, Dong
    Li, Quanxu
    Yuan, Xiuling
    [J]. APPLIED ENERGY, 2009, 86 (09) : 1697 - 1703
  • [10] Performance analysis of liquid desiccant dehumidification systems
    Jain, Sanjeev
    Bansal, P. K.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (05): : 861 - 872