Electric field simulations for transcranial brain stimulation using FEM: an efficient implementation and error analysis

被引:93
作者
Saturnino, Guilherme B. [1 ,2 ]
Madsen, Kristoffer H. [1 ,3 ]
Thielscher, Axel [1 ,2 ]
机构
[1] Copenhagen Univ Hosp Hvidovre, Danish Res Ctr Magnet Resonance, Ctr Funct & Diagnost Imaging & Res, Hvidovre, Denmark
[2] Tech Univ Denmark, Dept Hlth Technol, Lyngby, Denmark
[3] Tech Univ Denmark, Dept Appl Math & Comp Sci, Lyngby, Denmark
关键词
transcranial magnetic stimulation; transcranial electrical stimulation; finite element method; head models; volume conductor models; MAGNETIC STIMULATION; MODEL; EEG; COMPUTATION;
D O I
10.1088/1741-2552/ab41ba
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Transcranial magnetic stimulation (TMS) and transcranial electric stimulation (TES) modulate brain activity non-invasively by generating electric fields either by electromagnetic induction or by injecting currents via skin electrodes. Numerical simulations based on anatomically detailed head models of the TMS and TES electric fields can help us to understand and optimize the spatial stimulation pattern in the brain. However, most realistic simulations are still slow, and the role of anatomical fidelity on simulation accuracy has not been evaluated in detail so far. Approach. We present and validate a new implementation of the finite element method (FEM) for TMS and TES that is based on modern algorithms and libraries. We also evaluate the convergence of the simulations and estimate errors stemming from numerical and modelling aspects. Main results. Comparisons with analytical solutions for spherical phantoms validate our new FEM implementation, which is three to six times faster than previous implementations. The convergence results suggest that accurately capturing the tissue geometry in addition to choosing a sufficiently accurate numerical method is of fundamental importance for accurate simulations. Significance. The new implementation allows for a substantial increase in computational efficiency of FEM TMS and TES simulations. This is especially relevant for applications such as the systematic assessment of model uncertainty and the optimization of multi-electrode TES montages. The results of our systematic error analysis allow the user to select the best tradeoff between model resolution and simulation speed for a specific application. The new FEM code is openly available as a part of our open-source software SimNIBS 3.0.
引用
收藏
页数:15
相关论文
共 53 条
[1]  
[Anonymous], CEREB CORTEX
[2]  
[Anonymous], 1999, CLASSICAL ELECTRODYN
[3]  
[Anonymous], SOFTWARE TOOLKIT FAS
[4]  
[Anonymous], BIORXIV611962
[5]   A lightweight approach to repairing digitized polygon meshes [J].
Attene, Marco .
VISUAL COMPUTER, 2010, 26 (11) :1393-1406
[6]  
Balay Satish., 2018, PETSC
[7]   Clinical research with transcranial direct current stimulation (tDCS): Challenges and future directions [J].
Brunoni, Andre Russowsky ;
Nitsche, Michael A. ;
Bolognini, Nadia ;
Bikson, Marom ;
Wagner, Tim ;
Merabet, Lotfi ;
Edwards, Dylan J. ;
Valero-Cabre, Antoni ;
Rotenberg, Alexander ;
Pascual-Leone, Alvaro ;
Ferrucci, Roberta ;
Priori, Alberto ;
Boggio, Paulo Sergio ;
Fregni, Felipe .
BRAIN STIMULATION, 2012, 5 (03) :175-195
[8]   Cortical thickness and central surface estimation [J].
Dahnke, Robert ;
Yotter, Rachel Aine ;
Gaser, Christian .
NEUROIMAGE, 2013, 65 :336-348
[9]  
Datta Abhishek, 2012, Front Psychiatry, V3, P91, DOI 10.3389/fpsyt.2012.00091
[10]   Optimized multi-electrode stimulation increases focality and intensity at target [J].
Dmochowski, Jacek P. ;
Datta, Abhishek ;
Bikson, Marom ;
Su, Yuzhuo ;
Parra, Lucas C. .
JOURNAL OF NEURAL ENGINEERING, 2011, 8 (04)