Electrochemical Resistive DNA Biosensor for the Detection of HPV Type 16

被引:21
|
作者
Espinosa, Jose R. [1 ,2 ]
Galvan, Marisol [3 ]
Quinones, Arturo S. [3 ]
Ayala, Jorge L. [3 ]
Avila, Veronica [4 ]
Duron, Sergio M. [3 ]
机构
[1] Univ Autonoma Zacatecas, Unidad Acad Ingn Elect, Av Ramon Lopez Velarde 801, Zacatecas 98000, Zacatecas, Mexico
[2] Univ Autonoma Zacatecas, Ingn Mecan, Unidad Acad Ingn 1, Av Ramon Lopez Velarde 801, Zacatecas 98000, Zacatecas, Mexico
[3] Univ Autonoma Zacatecas, Unidad Acad Ciencias Quim, Campus Siglo XXI,Edif 6, Zacatecas 98160, Zacatecas, Mexico
[4] Inst Politecn Nacl, Unidad Profes Interdisciplinaria Ingn, Ingn Ambiental, Campus Zacatecas, Zacatecas 98160, Zacatecas, Mexico
来源
MOLECULES | 2021年 / 26卷 / 11期
关键词
current relaxation; electrochemical HPV-16 DNA biosensor; potential relaxation; faradaic current; PEPTIDE NUCLEIC-ACID; HUMAN-PAPILLOMAVIRUS; DESIGN; PREVALENCE; SENSORS; PROTEIN;
D O I
10.3390/molecules26113436
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this work, a low-cost and rapid electrochemical resistive DNA biosensor based on the current relaxation method is described. A DNA probe, complementary to the specific human papillomavirus type 16 (HPV-16) sequence, was immobilized onto a screen-printed gold electrode. DNA hybridization was detected by applying a potential step of 30 mV to the system, composed of an external capacitor and the modified electrode DNA/gold, for 750 mu s and then relaxed back to the OCP, at which point the voltage and current discharging curves are registered for 25 ms. From the discharging curves, the potential and current relaxation were evaluated, and by using Ohm's law, the charge transfer resistance through the DNA-modified electrode was calculated. The presence of a complementary sequence was detected by the change in resistance when the ssDNA is transformed in dsDNA due to the hybridization event. The target DNA concentration was detected in the range of 5 to 20 nM. The results showed a good fit to the regression equation Delta R-total(Omega) = 2.99 x [DNA] + 81.55, and a detection limit of 2.39 nM was obtained. As the sensing approach uses a direct current, the electronic architecture of the biosensor is simple and allows for the separation of faradic and nonfaradaic contributions. The simple electrochemical resistive biosensor reported here is a good candidate for the point-of-care diagnosis of HPV at a low cost and in a short detection time.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] DNA Biosensor Based on Double-Layer Discharge for the Detection of HPV Type 16
    Espinosa, Jose R.
    Galvan, Marisol
    Quinones, Arturo S.
    Ayala, Jorge L.
    Duron, Sergio M.
    SENSORS, 2019, 19 (18)
  • [2] A new DNA sensor design for the simultaneous detection of HPV type 16 and 18 DNA
    Jampasa, Sakda
    Siangproh, Weena
    Laocharoensuk, Rawiwan
    Yanatatsaneejit, Pattamawadee
    Vilaivan, Tirayut
    Chailapakul, Orawon
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 265 : 514 - 521
  • [3] Detection of HPV 16 and HPV 18 DNA in the blood of patients with cervical cancer
    Kay, P
    Allan, B
    Denny, L
    Hoffman, M
    Williamson, AL
    JOURNAL OF MEDICAL VIROLOGY, 2005, 75 (03) : 435 - 439
  • [4] An ultrasensitive electrochemical DNA biosensor based on graphene/Au nanorod/polythionine for human papillomavirus DNA detection
    Huang, Huayu
    Bai, Wanqiao
    Dong, Changxun
    Guo, Rui
    Liu, Zhihua
    BIOSENSORS & BIOELECTRONICS, 2015, 68 : 442 - 446
  • [5] Electrochemical DNA biosensor for potential carcinogen detection in food sample
    Sani, Nor Diyana Md
    Heng, Lee Yook
    Marugan, Radha Swathe Priya Malon
    Rajab, Nor Fadilah
    FOOD CHEMISTRY, 2018, 269 : 503 - 510
  • [6] An ultrasensitive electrochemical DNA biosensor for monitoring Human papillomavirus-16 (HPV-16) using graphene oxide/Ag/Au nano-biohybrids
    Pareek, Sakshi
    Jain, Utkarsh
    Bharadwaj, Mausumi
    Saxena, Kirti
    Roy, Souradeep
    Chauhan, Nidhi
    ANALYTICAL BIOCHEMISTRY, 2023, 663
  • [7] Development of a lateral flow strip biosensor based on copper oxide nanoparticles for rapid and sensitive detection of HPV16 DNA
    Yang, Zheng
    Yi, Chun
    Lv, Sijia
    Sheng, Yuhao
    Wen, Wei
    Zhang, Xiuhua
    Wang, Shengfu
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 285 : 326 - 332
  • [8] Detection of high-risk HPV 16 genotypes in cervical cancers using isothermal DNA amplification with electrochemical genosensor
    Nakowong, Panisara
    Chatchawal, Patutong
    Chaibun, Thanyarat
    Boonapatcharoen, Nimaradee
    Promptmas, Chamras
    Buajeeb, Waranun
    Lee, Su Yin
    Jearanaikoon, Patcharee
    Lertanantawong, Benchaporn
    TALANTA, 2024, 269
  • [9] Towards the detection of human papillomavirus infection by a reagentless electrochemical peptide biosensor
    Piro, B.
    Kapella, A.
    Le, V. H.
    Anquetin, G.
    Zhang, Q. D.
    Reisberg, S.
    Noel, V.
    Tran, L. D.
    Duc, H. T.
    Pham, M. C.
    ELECTROCHIMICA ACTA, 2011, 56 (28) : 10688 - 10693
  • [10] Plasmid encoding papillomavirus type 16 (HPV 16) DNA constructed with codon optimization improved the immunogenicity against HPV infection
    Cheung, YK
    Cheng, SCS
    Sin, FWY
    Xie, Y
    VACCINE, 2004, 23 (05) : 629 - 638