Comparative Study of Image Quality in Time-Correlated Single-Photon Counting Computed Tomography

被引:6
|
作者
Gaudreault, David [1 ,2 ]
Rossignol, Julien [1 ,2 ]
Berube-Lauziere, Yves [2 ]
Fontaine, Rejean [1 ,2 ]
机构
[1] Univ Sherbrooke, Inst Interdisciplinaire Innovat Technol, Sherbrooke, PQ J1K 2R1, Canada
[2] Univ Sherbrooke, Dept Genie Elect & Genie Informat, Sherbrooke, PQ J1K 2R1, Canada
关键词
Photonics; Detectors; Computed tomography; X-ray imaging; Image reconstruction; Timing jitter; Phantoms; Computed tomography (CT); cone-beam computed tomography; digital scatter rejection; photon counting; pulsed X-rays; scatter noise; time-correlated single-photon counting (TCSPC); time-of-flight scatter rejection; time-of-flight (TOF);
D O I
10.1109/TRPMS.2020.3017702
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computed tomography (CT) is widely used in medical imaging to reconstruct a 3-D image of a patient. To limit the radiation dose applied to patients, researches focus on reducing the statistical noise or increasing the contrast in the image. Recently, time-correlated single-photon counting (TCSPC) CT-also known as time-of-flight (TOF) CT-has been proposed to reduce scatter contribution to images and its negative effects on image quality. This technique uses the TOF information of X-ray photons to sort out scattered and ballistic photons without energy measurement. This article compares simulated images quality obtained from different CT scanner implementations (fan-beam, cone-beam with and without anti-scatter grids, and TCSPC). The contrast-to-noise ratio (CNR), the scattered-to-primary ratio (SPR), the inaccuracy of the computed attenuation value, and the cup artifact magnitude are used as comparison metrics to study the overall sensitivity of the different scanner implementations to scatter contribution. Using timing jitters of 200, 100, and 50 ps, the simulations demonstrate that the TCSPC implementation improves the CNR, accuracy, and cup artifact levels of the reconstructed images, when compared to a cone-beam CT, by reducing its scatter contribution. A 10-ps timing jitter on the measured time of flight leads to an image quality similar to fan-beam CT.
引用
收藏
页码:343 / 349
页数:7
相关论文
共 50 条
  • [41] Multiple wavelength time-of-flight sensor based on time-correlated single-photon counting
    Buller, GS
    Harkins, RD
    McCarthy, A
    Hiskett, PA
    MacKinnon, GR
    Smith, GR
    Sung, R
    Wallace, AM
    Lamb, RA
    Ridley, KD
    Rarity, JG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (08): : 1 - 7
  • [42] Time-correlated single-photon counting system based on a monolithic time-to-amplitude converter
    Antonioli, Sebastiano
    Crotti, Matteo
    Cuccato, Andrea
    Rech, Ivan
    Ghioni, Massimo
    JOURNAL OF MODERN OPTICS, 2012, 59 (17) : 1512 - 1524
  • [43] Multiplexed single-photon counting .1. A time-correlated fluorescence lifetime camera
    McLoskey, D
    Birch, DJS
    Sanderson, A
    Suhling, K
    Welch, E
    Hicks, PJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (06): : 2228 - 2237
  • [44] FLUORESCENCE LIFETIME MEASUREMENTS UNDER A MICROSCOPE BY THE TIME-CORRELATED SINGLE-PHOTON COUNTING TECHNIQUE
    MINAMI, T
    KAWAHIGASHI, M
    SAKAI, Y
    SHIMAMOTO, K
    HIRAYAMA, S
    JOURNAL OF LUMINESCENCE, 1986, 35 (05) : 247 - 253
  • [45] Scintillation index measurement using time-correlated single-photon counting laser radar
    Henriksson, Markus
    Sjoqvist, Lars
    OPTICAL ENGINEERING, 2014, 53 (08)
  • [46] Multiplexed single-photon counting .2. The statistical theory of time-correlated measurements
    Suhling, K
    McLoskey, D
    Birch, DJS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (06): : 2238 - 2246
  • [47] Fast calculation of fluorescence correlation data with asynchronous time-correlated single-photon counting
    Wahl, M
    Gregor, I
    Patting, M
    Enderlein, J
    OPTICS EXPRESS, 2003, 11 (26): : 3583 - 3591
  • [48] PERFORMANCE COMPARISON OF A SINGLE-PHOTON AVALANCHE-DIODE WITH A MICROCHANNEL-PLATE PHOTOMULTIPLIER IN TIME-CORRELATED SINGLE-PHOTON COUNTING
    LOUIS, T
    SCHATZ, GH
    KLEINBOLTING, P
    HOLZWARTH, AR
    RIPAMONTI, G
    COVA, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (07): : 1148 - 1152
  • [49] Multi-photon contamination in the time-correlated single photon counting
    Wang, Zhaomin, 2000, Chinese Optical Soc, China (20):
  • [50] RAPID, QUANTITATIVE MEASUREMENTS USING TIME-CORRELATED SINGLE-PHOTON COUNTING AND TIME-FILTERED DETECTION
    NOWAK, SA
    LYTLE, FE