Comparative Study of Image Quality in Time-Correlated Single-Photon Counting Computed Tomography

被引:6
|
作者
Gaudreault, David [1 ,2 ]
Rossignol, Julien [1 ,2 ]
Berube-Lauziere, Yves [2 ]
Fontaine, Rejean [1 ,2 ]
机构
[1] Univ Sherbrooke, Inst Interdisciplinaire Innovat Technol, Sherbrooke, PQ J1K 2R1, Canada
[2] Univ Sherbrooke, Dept Genie Elect & Genie Informat, Sherbrooke, PQ J1K 2R1, Canada
关键词
Photonics; Detectors; Computed tomography; X-ray imaging; Image reconstruction; Timing jitter; Phantoms; Computed tomography (CT); cone-beam computed tomography; digital scatter rejection; photon counting; pulsed X-rays; scatter noise; time-correlated single-photon counting (TCSPC); time-of-flight scatter rejection; time-of-flight (TOF);
D O I
10.1109/TRPMS.2020.3017702
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computed tomography (CT) is widely used in medical imaging to reconstruct a 3-D image of a patient. To limit the radiation dose applied to patients, researches focus on reducing the statistical noise or increasing the contrast in the image. Recently, time-correlated single-photon counting (TCSPC) CT-also known as time-of-flight (TOF) CT-has been proposed to reduce scatter contribution to images and its negative effects on image quality. This technique uses the TOF information of X-ray photons to sort out scattered and ballistic photons without energy measurement. This article compares simulated images quality obtained from different CT scanner implementations (fan-beam, cone-beam with and without anti-scatter grids, and TCSPC). The contrast-to-noise ratio (CNR), the scattered-to-primary ratio (SPR), the inaccuracy of the computed attenuation value, and the cup artifact magnitude are used as comparison metrics to study the overall sensitivity of the different scanner implementations to scatter contribution. Using timing jitters of 200, 100, and 50 ps, the simulations demonstrate that the TCSPC implementation improves the CNR, accuracy, and cup artifact levels of the reconstructed images, when compared to a cone-beam CT, by reducing its scatter contribution. A 10-ps timing jitter on the measured time of flight leads to an image quality similar to fan-beam CT.
引用
收藏
页码:343 / 349
页数:7
相关论文
共 50 条
  • [31] 8-channel acquisition system for time-correlated single-photon counting
    Antonioli, S.
    Miari, L.
    Cuccato, A.
    Crotti, M.
    Rech, I.
    Ghioni, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (06):
  • [32] Time-correlated single-photon counting study of multiple photoluminescence lifetime components of silicon nanoclusters
    Diamare, D.
    Wojdak, M.
    Lettieri, S.
    Kenyon, A. J.
    JOURNAL OF LUMINESCENCE, 2013, 136 : 57 - 62
  • [33] Increasing the collection efficiency of time-correlated single-photon counting with single-photon avalanche diodes using immersion lenses
    Pichette, Charles
    Giudice, Andrea
    Thibault, Simon
    Berube-Lauziere, Yves
    APPLIED OPTICS, 2016, 55 (33) : 9555 - 9562
  • [34] SPAD Smart Pixel for Time-of-Flight and Time-Correlated Single-Photon Counting Measurements
    Villa, F.
    Markovic, B.
    Bellisai, S.
    Bronzi, D.
    Tosi, A.
    Zappa, F.
    Tisa, S.
    Durini, D.
    Weyers, S.
    Paschen, U.
    Brockherde, W.
    IEEE PHOTONICS JOURNAL, 2012, 4 (03): : 795 - 804
  • [35] Information-Theoretical Analysis of Time-Correlated Single-Photon Counting Measurements of Single Molecules
    Talaga, David S.
    JOURNAL OF PHYSICAL CHEMISTRY A, 2009, 113 (17): : 5251 - 5263
  • [36] Ranging and three-dimensional imaging using time-correlated single-photon counting
    Buller, Gerald S.
    Wallace, Andrew M.
    McCarthy, Aongus
    Lamb, Robert A.
    ELECTRO-OPTICAL AND INFRARED SYSTEMS: TECHNOLOGY AND APPLICATIONS IV, 2007, 6737
  • [37] Long-range depth imaging using time-correlated single-photon counting
    Krichel, Nils J.
    McCarthy, Aongus
    Wallace, Andrew M.
    Ye, Jing
    Buller, Gerald S.
    DETECTORS AND IMAGING DEVICES: INFRARED, FOCAL PLANE, SINGLE PHOTON, 2010, 7780
  • [38] FLUORESCENCE SPECTROSCOPY THROUGH AN OPTICAL FIBER WITH A TIME-CORRELATED SINGLE-PHOTON COUNTING METHOD
    KUSHIDA, T
    WATANABE, J
    KINOSHITA, S
    JOURNAL OF LUMINESCENCE, 1984, 31-2 (DEC) : 718 - 720
  • [39] Time-of-flight optical ranging system based on time-correlated single-photon counting
    Massa, JS
    Buller, GS
    Walker, AC
    Cova, S
    Umasuthan, M
    Wallace, AM
    APPLIED OPTICS, 1998, 37 (31): : 7298 - 7304
  • [40] Photonic emission analysis of cipher chips based on time-correlated single-photon counting
    Wang Hong-Sheng
    Ji Dao-Gang
    Gao Yan-Lei
    Zhang Yang
    Chen Kai-Yan
    Chen Jun-Guang
    Wu Ling-An
    Wang Yong-Zhong
    ACTA PHYSICA SINICA, 2015, 64 (05)