Autocalibration of accelerometer data for free-living physical activity assessment using local gravity and temperature: an evaluation on four continents

被引:416
作者
van Hees, Vincent T. [1 ,7 ]
Fang, Zhou [2 ,3 ]
Langford, Joss [3 ]
Assah, Felix [4 ]
Mohammad, Anwar [5 ]
da Silva, Inacio C. M. [6 ]
Trenell, Michael I. [1 ]
White, Tom [7 ]
Wareham, Nicholas J. [7 ]
Brage, Soren [7 ]
机构
[1] Newcastle Univ, Inst Cellular Med, MoveLab, Newcastle Upon Tyne, Tyne & Wear, England
[2] Univ Oxford, Dept Stat, Oxford OX1 3TG, England
[3] Activinsight Ltd, Kimbolton, Cambs, England
[4] Univ Yaounde, Yaounde, Cameroon
[5] Dasman Diabet Inst, Kuwait, Kuwait
[6] Univ Fed Pelotas, Postgrad Program Epidemiol, Pelotas, Brazil
[7] Univ Cambridge, Epidemiol Unit, MRC, Cambridge, England
基金
英国惠康基金; 英国医学研究理事会;
关键词
calibration; accelerometry; physical activity; epidemiology; GENE-Activ; TRIAXIAL ACCELEROMETER; CALIBRATION; WRIST; ASSOCIATION; HEALTH; OUTPUT; TIME;
D O I
10.1152/japplphysiol.00421.2014
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Wearable acceleration sensors are increasingly used for the assessment of free-living physical activity. Acceleration sensor calibration is a potential source of error. This study aims to describe and evaluate an autocalibration method to minimize calibration error using segments within the free-living records (no extra experiments needed). The autocalibration method entailed the extraction of nonmovement periods in the data, for which the measured vector magnitude should ideally be the gravitational acceleration (1 g); this property was used to derive calibration correction factors using an iterative closest-point fitting process. The reduction in calibration error was evaluated in data from four cohorts: UK (n = 921), Kuwait (n = 120), Cameroon (n = 311), and Brazil (n = 200). Our method significantly reduced calibration error in all cohorts (P < 0.01), ranging from 16.6 to 3.0 mg in the Kuwaiti cohort to 76.7 to 8.0 mg error in the Brazil cohort. Utilizing temperature sensor data resulted in a small nonsignificant additional improvement (P > 0.05). Temperature correction coefficients were highest for the z-axis, e.g., 19.6-mg offset per 5 degrees C. Further, application of the autocalibration method had a significant impact on typical metrics used for describing human physical activity, e.g., in Brazil average wrist acceleration was 0.2 to 51% lower than uncalibrated values depending on metric selection (P < 0.01). The autocalibration method as presented helps reduce the calibration error in wearable acceleration sensor data and improves comparability of physical activity measures across study locations. Temperature ultization seems essential when temperature deviates substantially from the average temperature in the record but not for multiday summary measures.
引用
收藏
页码:738 / 744
页数:7
相关论文
共 30 条
  • [1] Analog Devices, 2013, ADXL345 SPEC
  • [2] Urbanization, Physical Activity, and Metabolic Health in Sub-Saharan Africa
    Assah, Felix K.
    Ekelund, Ulf
    Brage, Soren
    Mbanya, Jean Claude
    Wareham, Nicholas J.
    [J]. DIABETES CARE, 2011, 34 (02) : 491 - 496
  • [3] Predicting Physical Activity Energy Expenditure Using Accelerometry in Adults From Sub-Sahara Africa
    Assah, Felix K.
    Ekelund, Ulf
    Brage, Soren
    Corder, Kirsten
    Wright, Antony
    Mbanya, Jean C.
    Wareham, Nicholas J.
    [J]. OBESITY, 2009, 17 (08) : 1588 - 1595
  • [4] Sedentary Time in Children: Influence of Accelerometer Processing on Health Relations
    Atkin, Andrew J.
    Ekelund, Ulf
    Moller, Niels Christian
    Froberg, Karsten
    Sardinha, Luis B.
    Andersen, Lars Bo
    Brage, Soren
    [J]. MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2013, 45 (06) : 1097 - 1104
  • [5] A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity
    Bouten, CVC
    Koekkoek, KTM
    Verduin, M
    Kodde, R
    Janssen, JD
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) : 136 - 147
  • [6] Physical activity, cardio-respiratory fitness, and metabolic traits in rural mexican tarahumara
    Christensen, Dirk Lund
    Alcala-Sanchez, Imelda
    Leal-Berumen, Irene
    Conchas-Ramirez, Miguel
    Brage, Soren
    [J]. AMERICAN JOURNAL OF HUMAN BIOLOGY, 2012, 24 (04) : 558 - 561
  • [7] A Real-Time and Self-Calibrating Algorithm Based on Triaxial Accelerometer Signals for the Detection of Human Posture and Activity
    Curone, Davide
    Bertolotti, Gian Mario
    Cristiani, Andrea
    Secco, Emanuele Lindo
    Magenes, Giovanni
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (04): : 1098 - 1105
  • [8] Validation of the GENEA Accelerometer
    Esliger, Dale W.
    Rowlands, Ann V.
    Hurst, Tina L.
    Catt, Michael
    Murray, Peter
    Eston, Roger G.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (06) : 1085 - 1093
  • [9] Autocalibration of MEMS Accelerometers
    Frosio, Iuri
    Pedersini, Federico
    Borghese, N. Alberto
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (06) : 2034 - 2041
  • [10] Gietzelt M, 2008, 2008 2 INT C PERV CO