Enhanced characterization of calcified areas in intravascular ultrasound virtual histology images by quantification of the acoustic shadow: validation against computed tomography coronary angiography

被引:12
|
作者
Broersen, Alexander [1 ]
de Graaf, Michiel A. [2 ,3 ]
Eggermont, Jeroen [1 ]
Wolterbeek, Ron [4 ]
Kitslaar, Pieter H. [1 ,5 ]
Dijkstra, Jouke [1 ]
Bax, Jeroen J. [2 ]
Reiber, Johan H. C. [1 ,5 ]
Scholte, Arthur J. [2 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, Div Image Proc, Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Cardiol, Albinusdreef 2,Postal Zone 2300 RC, NL-2333 ZA Leiden, Netherlands
[3] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[4] Leiden Univ, Med Ctr, Dept Med Stat & Bioinformat, Leiden, Netherlands
[5] Medis Med Imaging Syst Bv, Leiden, Netherlands
来源
关键词
Quantitative CT angiography; Plaque constitution; Tissue characterization; Acoustic shadow; ARTERY-DISEASE; NECROTIC CORE; PLAQUE COMPOSITION; QUANTITATIVE-ANALYSIS; DENSE CALCIUM; ATHEROSCLEROSIS; ACCURACY; REGISTRY; TISSUE; IVUS;
D O I
10.1007/s10554-015-0820-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We enhance intravascular ultrasound virtual histology (VH) tissue characterization by fully automatic quantification of the acoustic shadow behind calcified plaque. VH is unable to characterize atherosclerosis located behind calcifications. In this study, the quantified acoustic shadows are considered calcified to approximate the real dense calcium (DC) plaque volume. In total, 57 patients with 108 coronary lesions were included. A novel post-processing step is applied on the VH images to quantify the acoustic shadow and enhance the VH results. The VH and enhanced VH results are compared to quantitative computed tomography angiography (QTA) plaque characterization as reference standard. The correlation of the plaque types between enhanced VH and QTA differs significantly from the correlation with unenhanced VH. For DC, the correlation improved from 0.733 to 0.818. Instead of an underestimation of DC in VH with a bias of 8.5 mm(3), there was a smaller overestimation of 1.1 mm(3) in the enhanced VH. Although tissue characterization within the acoustic shadow in VH is difficult, the novel algorithm improved the DC tissue characterization. This algorithm contributes to accurate assessment of calcium on VH and could be applied in clinical studies.
引用
收藏
页码:543 / 552
页数:10
相关论文
共 50 条
  • [31] Validation of right coronary artery lumen area from cardiac computed tomography against intravascular ultrasound
    Hengfei Cui
    Yong Xia
    Yanning Zhang
    Liang Zhong
    Machine Vision and Applications, 2018, 29 : 1287 - 1298
  • [32] Type 2 diabetes is associated with more advanced coronary atherosclerosis on multislice computed tomography and virtual histology intravascular ultrasound
    Pundziute, Gabija
    Schuijf, Joanne D.
    Jukema, J. Wouter
    van Werkhoven, Jacob M.
    Nucifora, Gaetano
    Decramer, Isabel
    Sarno, Giovanna
    Vanhoenacker, Piet K.
    Reiber, Johannes H. C.
    Wijns, William
    Bax, Jeroen J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (03) : 376 - 383
  • [33] Relationship between Coronary Artery Calcium Score by Multidetector Computed Tomography and Plaque Components by Virtual Histology Intravascular Ultrasound
    Choi, Yun Ha
    Hong, Young Joon
    Park, In Hyae
    Jeong, Myung Ho
    Ahmed, Khurshid
    Hwang, Seung Hwan
    Lee, Min Goo
    Park, Keun-Ho
    Sim, Doo Sun
    Kim, Ju Han
    Ahn, Youngkeun
    Cho, Jeong Gwan
    Park, Jong Chun
    Kang, Jung Chaee
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2011, 26 (08) : 1052 - 1060
  • [34] Plaque quantification by coronary computed tomography angiography using intravascular ultrasound as a reference standard: a comparison between standard and last generation computed tomography scanners
    Conte, Edoardo
    Mushtaq, Saima
    Pontone, Gianluca
    Li Piani, Letizia
    Ravagnani, Paolo
    Galli, Stefano
    Collet, Carlos
    Sonck, Jeroen
    Di Odoardo, Luca
    Guglielmo, Marco
    Baggiano, Andrea
    Trabattoni, Daniela
    Annoni, Andrea
    Mancini, Maria Elisabetta
    Formenti, Alberto
    Muscogiuri, Giuseppe
    Magatelli, Marco
    Nicoli, Flavia
    Poggi, Carlotta
    Fiorentini, Cesare
    Bartorelli, Antonio L.
    Pepi, Mauro
    Montorsi, Piero
    Andreini, Daniele
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2020, 21 (02) : 191 - 201
  • [35] Characterization of non-calcified coronary plaque by 64-slice multidetector computed tomography compared with virtual histology
    Choi, Byoung-Joo
    Tahk, Seung-Jea
    Shin, Joon-Han
    Yoon, Myeong-Ho
    Choi, So-Yeon
    Lim, Hong-Seok
    Hwang, Gyo-Seung
    Kang, Soo-Jin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A161 - A161
  • [36] A Novel Coronary Computed Tomography Angiography DeepLearning Methodology for Coronary Atheroma Quantification and Characterization Trained Using Near-Infrared Spectroscopy-Intravascular Ultrasound
    Ramasamy, Anantharaman
    Sokooti, Hessam
    Zhang, Xiaotong
    Tzorovili, Evangelia
    Bajaj, Retesh
    Kitslaar, Pieter
    Amersey, Rajiv
    Jain, Ajay
    Ozkor, Mick
    Reiber, Johan
    Dijkstra, Jouke
    Serruys, Patrick
    Torii, Ryo
    Moon, James
    Mathur, Anthony
    Baumbach, Andreas
    Pugliese, Francesca
    Bourantas, Christos
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B98 - B99
  • [37] Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography - A comparative study with quantitative coronary angiography and intravascular ultrasound
    Leber, AW
    Knez, A
    von Ziegler, F
    Becker, A
    Nikolaou, K
    Paul, S
    Wintersperger, B
    Reiser, M
    Becker, CR
    Steinbeck, G
    Boekstegers, P
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) : 147 - 154
  • [38] Evaluation of coronary plaque type and composition on 320-row multidetector computed tomography: comparison to virtual histology intravascular ultrasound
    Van Velzen, J. E.
    Schuijf, J. D.
    De Graaf, F. R.
    Spano, F.
    Jukema, J. W.
    Schalij, M. J.
    Kroft, L. J.
    De Roos, A.
    Van der Wall, E. E.
    Bax, J. J.
    EUROPEAN HEART JOURNAL, 2010, 31 : 435 - 435
  • [39] Quantification and Characterization of Obstructive Coronary Plaques Using 64-Slice Computed Tomography: A Comparison With Intravascular Ultrasound
    Hur, Jin
    Kim, Young Jin
    Lee, Hye-Jeong
    Nam, Ji Eun
    Choe, Kyu Ok
    Seo, Jae Seung
    Choi, Dong-Hoon
    Kim, Jung-Sun
    Choi, Byoung Wook
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (02) : 186 - 192
  • [40] Quantification and Characterization of Noncalcified Coronary Plaque by High Definition Computed Tomography : Comparison with Integrated Backscatter Intravascular Ultrasound
    Takuma, Tsuda
    CIRCULATION, 2012, 126 (21)