R2*value derived from multi-echo Dixon technique can aid discrimination between benign and malignant focal liver lesions

被引:2
|
作者
Shi, Guang-Zi [1 ]
Chen, Hong [1 ]
Zeng, Wei-Ke [1 ]
Gao, Ming [1 ]
Wang, Meng-Zhu [2 ]
Zhang, Hui-Ting [2 ]
Shen, Jun [1 ]
机构
[1] Sun Yat Sen Univ, Sun Yat Sen Mem Hosp, Dept Radiol, 107 Yanjiang Rd West, Guangzhou 510120, Guangdong, Peoples R China
[2] Siemens Healthineers, MR Sci Mkt, Guangzhou 510120, Guangdong, Peoples R China
关键词
R2*; Multi-echo Dixon imaging; Hypoxia; Malignant lesion; Benign lesion; Focal liver lesion; APPARENT DIFFUSION-COEFFICIENT; NEPHROGENIC SYSTEMIC FIBROSIS; HEPATOCELLULAR-CARCINOMA; PRELIMINARY EXPERIENCE; MRI; DIAGNOSIS; IRON; DIFFERENTIATION; QUANTIFICATION; CHILDREN;
D O I
10.3748/wjg.v27.i12.1182
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND R2* estimation reflects the paramagnetism of the tumor tissue, which may be used to differentiate between benign and malignant liver lesions when contrast agents are contraindicated. AIM To investigate whether R2* derived from multi-echo Dixon imaging can aid differentiating benign from malignant focal liver lesions (FLLs) and the impact of 2D region of interest (2D-ROI) and volume of interest (VOI) on the outcomes. METHODS We retrospectively enrolled 73 patients with 108 benign or malignant FLLs. All patients underwent conventional abdominal magnetic resonance imaging and multi-echo Dixon imaging. Two radiologists independently measured the mean R2* values of lesions using 2D-ROI and VOI approaches. The Bland-Altman plot was used to determine the interobserver agreement between R2* measurements. Intraclass correlation coefficient (ICC) was used to determine the reliability between the two readers. Mean R2* values were compared between benign and malignant FFLs using the nonparametric Mann-Whitney test. Receiver operating characteristic curve analysis was used to determine the diagnostic performance of R2* in differentiation between benign and malignant FFLs. We compared the diagnostic performance of R2* measured by 2D-ROI and VOI approaches. RESULTS This study included 30 benign and 78 malignant FLLs. The interobserver reproducibility of R2* measurements was excellent for the 2D-ROI (ICC = 0.994) and VOI (ICC = 0.998) methods. Bland-Altman analysis also demonstrated excellent agreement. Mean R2* was significantly higher for malignant than benign FFLs as measured by 2D-ROI (P < 0.001) and VOI (P < 0.001). The area under the curve (AUC) of R2* measured by 2D-ROI was 0.884 at a cut-off of 25.2/s, with a sensitivity of 84.6% and specificity of 80.0% for differentiating benign from malignant FFLs. R2* measured by VOI yielded an AUC of 0.875 at a cut-off of 26.7/s in distinguishing benign from malignant FFLs, with a sensitivity of 85.9% and specificity of 76.7%. The AUCs of R2* were not significantly different between the 2D-ROI and VOI methods. CONCLUSION R2* derived from multi-echo Dixon imaging whether by 2D-ROI or VOI can aid in differentiation between benign and malignant FLLs.
引用
收藏
页码:1182 / 1193
页数:12
相关论文
共 4 条
  • [1] R2~* value derived from multi-echo Dixon technique can aid discrimination between benign and malignant focal liver lesions
    Guang-Zi Shi
    Hong Chen
    Wei-Ke Zeng
    Ming Gao
    Meng-Zhu Wang
    Hui-Ting Zhang
    Jun Shen
    World Journal of Gastroenterology, 2021, 27 (12) : 1182 - 1193
  • [2] Agreement between manual relaxometry and semi-automated scanner-based multi-echo Dixon technique for measuring liver T2*in a pediatric and young adult population
    Serai, Suraj D.
    Smith, Ethan A.
    Trout, Andrew T.
    Dillman, Jonathan R.
    PEDIATRIC RADIOLOGY, 2018, 48 (01) : 94 - 100
  • [3] Agreement between manual relaxometry and semi-automated scanner-based multi-echo Dixon technique for measuring liver T2* in a pediatric and young adult population
    Suraj D. Serai
    Ethan A. Smith
    Andrew T. Trout
    Jonathan R. Dillman
    Pediatric Radiology, 2018, 48 : 94 - 100
  • [4] Differentiation between Focal Malignant Marrow-Replacing Lesions and Benign Red Marrow Deposition of the Spine with T2*-Corrected Fat-Signal Fraction Map Using a Three-Echo Volume Interpolated Breath-Hold Gradient Echo Dixon Sequence
    Kim, Yong Pyo
    Kannengiesser, Stephan
    Paek, Mun-Young
    Kim, Sungjun
    Chung, Tae-Sub
    Yoo, Yeon Hwa
    Yoon, Choon-Sik
    Song, Ho-Taek
    Lee, Young Han
    Suh, Jin-Suck
    KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (06) : 781 - 791