A Method to Improve the Accuracy of the Bioelectrical Impedance Phase-Angle Measuring System

被引:0
|
作者
Nguyen Ngoc Tram [1 ]
Trinh Duc Nam [2 ]
Truong Xuan Thanh [3 ]
Tran Quang Do [4 ]
Dinh Hong Thai [5 ]
Vu Duy Hai [1 ]
机构
[1] Hanoi Univ Sci & Technol, Sch Elect Telecommun, Hanoi, Vietnam
[2] BME HUST, Minist Hlth, Dept Med Equipment & Contruct, Hanoi, Vietnam
[3] BME HUST, Friendship Hosp, Informat Technol Dept, Hanoi, Vietnam
[4] BME HUST, Bach Mai Hosp, Dept Med Equipment & Consumables, Hanoi, Vietnam
[5] BME HUST, Viet Duc Univ Hosp, Dept Med Equipment & Consumables, Hanoi, Vietnam
来源
2021 15TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING AND APPLICATIONS (ACOMP 2021) | 2021年
关键词
Bioelectrical impedance; phase-angle; nutritional assessment; voltage to current converter; comparator; phase lock loop; phase-difference detector; BODY-COMPOSITION; NUTRITIONAL-STATUS; CANCER; MALNUTRITION; MASS;
D O I
10.1109/ACOMP53746.2021.00030
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The bioelectric impedance phase difference (BIPA) is a characteristic quantity for the changes in the electrical properties of the tissue, obtained from the Bioelectrical Impedance Analysis (BIA). Nowadays, the need for an automatic, specialized and safe device to measure BIPA in medical facilities is very pressing. One method that has been proposed to measure this parameter is to use a multiplier and calculate the value of the phase difference between the two signals. The bias (mean) (+/- SD) of the measurement of the phase difference between two signals with programmed phases using this method was 0.5 +/- 0.2. Consequently, to improve the accuracy of the measurement results, this study was conducted to propose another signal processing method which is based on the comparator and the operating principle of the phase lock loop for the BIPA measurement system. This system still consists of an analog signal generator at 100kHz, a current source circuit. However, the signal processors which process signal received from the body consist of an analog-to-pulse converter and a phase-difference detector. The phase angle between the two signals is then calculated from the DC voltage obtained at the output of the phase-difference detector and compared with the programmed one. The phase difference between the two programmed signals ranges from 5 degrees to 8 degrees with an increment of 0.5 degrees. The obtained results show that the bias of the measurement performed by the system using the proposed method is -0.01, the precision was 0.07 and percentage error was 4.31%.
引用
收藏
页码:169 / 175
页数:7
相关论文
共 50 条
  • [1] A bioelectrical impedance phase angle measuring system for assessment of nutritional status
    Zhang, Guanghao
    Huo, Xiaolin
    Wu, Changzhe
    Zhang, Cheng
    Duan, Zhongping
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (06) : 3657 - 3664
  • [2] Bioelectrical Impedance Phase Angle and Morbidity and Mortality in Critically Ill Children
    Zamberlan, Patricia
    Feferbaum, Rubens
    Doria Filho, Ulysses
    de Carvalho, Werther Brunow
    Delgado, Artur Figueiredo
    NUTRITION IN CLINICAL PRACTICE, 2019, 34 (01) : 163 - 171
  • [3] Assessment of adult malnutrition and prognosis with bioelectrical impedance analysis: phase angle and impedance ratio
    Lukaski, Henry C.
    Kyle, Ursula G.
    Kondrup, Jens
    CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2017, 20 (05) : 330 - 339
  • [4] Bioelectrical impedance phase angle in sport: a systematic review
    Di Vincenzo, Olivia
    Marra, Maurizio
    Scalfi, Luca
    JOURNAL OF THE INTERNATIONAL SOCIETY OF SPORTS NUTRITION, 2019, 16 (01) : 1
  • [5] Bioelectrical impedance phase angle as a prognostic marker in chronic heart failure
    Colin-Ramirez, Eloisa
    Castillo-Martinez, Lilia
    Orea-Tejeda, Arturo
    Vazquez-Duran, Marisela
    Rodriguez, Ana E.
    Keirns-Davis, Candace
    NUTRITION, 2012, 28 (09) : 901 - 905
  • [6] Configuration of bioelectrical impedance measurements affects results for phase angle
    Jensen, Bjorn
    Braun, Wiebke
    Both, Markus
    Gallagher, Dympna
    Clark, Patricia
    Lopez Gonzalez, Desiree
    Klueckmann, Kristin
    Bosy-Westphal, Anja
    MEDICAL ENGINEERING & PHYSICS, 2020, 84 : 10 - 15
  • [7] Association of Bioelectrical Impedance Analysis-Derived Phase Angle and Sarcopenia in Older Adults
    Kilic, Mustafa Kemal
    Kizilarslanoglu, Muhammet Cemal
    Arik, Gunes
    Bolayir, Basak
    Kara, Ozgur
    Varan, Hacer Dogan
    Sumer, Fatih
    Kuyumcu, Mehmet Emin
    Halil, Meltem
    Ulger, Zekeriya
    NUTRITION IN CLINICAL PRACTICE, 2017, 32 (01) : 103 - 109
  • [8] Bioelectrical phase angle and impedance vector analysis - Clinical relevance and applicability of impedance parameters
    Norman, Kristina
    Stobaus, Nicole
    Pirlich, Matthias
    Bosy-Westphal, Anja
    CLINICAL NUTRITION, 2012, 31 (06) : 854 - 861
  • [9] Bioelectrical impedance (BIA)-derived phase angle in adults with obesity: A systematic review
    Di Vincenzo, Olivia
    Marra, Maurizio
    Sacco, Anna Maria
    Pasanisi, Fabrizio
    Scal, Luca
    CLINICAL NUTRITION, 2021, 40 (09) : 5238 - 5248
  • [10] Bioelectrical Impedance Phase Angle-Predictor of Blood Transfusion in Cardiac Surgery
    Ringaitiene, Donata
    Puodziukaite, Lina
    Vicka, Vaidas
    Gineityte, Dalia
    Serpytis, Mindaugas
    Sipylaite, Jurate
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (04) : 969 - 975