Directionally selective shading control in maritime sub-tropical and temperate climates: Life cycle energy implications for office buildings

被引:16
作者
Bunning, Myles E. [1 ]
Crawford, Robert H. [1 ]
机构
[1] Univ Melbourne, Fac Architecture Bldg & Planning, Melbourne, Vic 3010, Australia
关键词
Venetian shading; Embodied energy; Directionally selective shading; Life cycle energy; Office buildings; AUTOMATED VENETIAN BLIND; LIGHTING SYSTEM; WINDOW; COMFORT; IMPACT;
D O I
10.1016/j.buildenv.2016.05.009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Scheduling directionally selective shading devices to increase or decrease their level of occlusion relative to the total incoming solar radiation has the benefit of controlling solar heat gain during a variety of sky conditions and allowing more constant illuminance levels to be achieved within a building. In this study, hourly sky condition and annual solar angles were used to describe the tilt of the slats of an external directionally selective shading control for an external venetian blind on an office building in Melbourne and Brisbane, Australia. The life cycle energy demand associated with this shading control was compared to a static base case with an external overhang and internal venetians. The analysis was extended to the HVAC system which was sized to account for the effect of the shading on solar gain and the artificial lighting requirement. It was found that the embodied energy of the HVAC and shading components accounted for between 21.7% and 25.5% of the total. life cycle energy of these systems over 25 years. There was a reduction in embodied and operational energy requirements over a 25 year life cycle for the external venetian blind control of 24.9% for Melbourne and 24.0% for Brisbane relative to the static base case. Based on the simulation results, office buildings with equator facing facades located in similar climates and latitudes may have the potential for equivalent life cycle energy reductions when external directionally selective shading controls are employed to moderate overheating and daylighting. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:275 / 285
页数:11
相关论文
共 45 条
[1]  
*ABS, 2001, INP OUTP TABL AUSTR
[2]  
ABS, 2001, EN GREENH GAS EM ACC
[3]  
Ali Syed Moazzam, 2013, INT J ADV RES ENG TE, V4, P316
[4]  
[Anonymous], 2009, ASHRAE HDB
[5]  
[Anonymous], CLIM DAT ONL
[6]  
Boardass W., 1994, Proceedings of the National Lighting Conference and Daylighting Colloquium, Cambridge, Robinson College, P243
[7]   Sensitivity of the human circadian system to short-wavelength (420-nm) light [J].
Brainard, George C. ;
Sliney, David ;
Hanifin, John P. ;
Glickman, Gena ;
Byrne, Brenda ;
Greeson, Jeffrey N. ;
Jasser, Samar ;
Gerner, Edward ;
Rollag, Mark D. .
JOURNAL OF BIOLOGICAL RHYTHMS, 2008, 23 (05) :379-386
[8]   Window and advanced glazing systems life cycle assessment [J].
Citherlet, S ;
Di Guglielmo, F ;
Gay, JB .
ENERGY AND BUILDINGS, 2000, 32 (03) :225-234
[9]  
Crawford RH, 2011, LIFE CYCLE ASSESSMENT IN THE BUILT ENVIRONMENT, P1
[10]  
Demirbilek N., 2004, P SOL HARV 2002 FORG