Transient Performance Improvement of Wind Turbines With Doubly Fed Induction Generators Using Nonlinear Control Strategy

被引:80
作者
Rahimi, Mohsen [1 ]
Parniani, Mostafa [1 ]
机构
[1] Sharif Univ Technol, Dept Elect Engn, Tehran 111559363, Iran
关键词
Doubly fed induction generator (DFIG); internal dynamics; nonlinear control; transient performance; wind turbine (WT); SPEED;
D O I
10.1109/TEC.2009.2032169
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper first discusses dynamic characteristics of wind turbines with doubly fed induction generator (DFIG). Rotor back electromotive force (EMF) voltages in DFIG reflect the effects of stator dynamics on rotor current dynamics, and have an important role on rotor inrush current during the generator voltage dip. Compensation of these voltages can improve DFIG ride-through capability and limit the rotor current transients. It is found that the electrical dynamics of the DFIG are in nonminimum phase for certain operating conditions. Also, it is shown that the dynamics of DFIG, under compensation of rotor back EMF and grid voltages, behave as a partially linearizable system containing internal and external dynamics. The internal and external dynamics of DFIG include stator and rotor dynamics, respectively. It is found that under certain operating conditions, the internal dynamics, and thus, the entire DFIG system becomes unstable. This phenomenon deteriorates the DFIG postfault behavior. Since the DFIG electrical dynamics are nonlinear; the linear control scheme cannot properly work under large voltage dips. We address this problem by means of a nonlinear controller. The proposed approach stabilizes the internal dynamics through rotor voltage control, and improves the dynamic behavior of the DFIG after clearing the fault.
引用
收藏
页码:514 / 525
页数:12
相关论文
共 21 条
  • [1] Ackermann T, 2005, WIND POWER IN POWER SYSTEMS, P1, DOI 10.1002/0470012684
  • [2] [Anonymous], 1995, Nonlinear systems
  • [3] Erlich I, 2007, 2007 POWER CONVERSION CONFERENCE - NAGOYA, VOLS 1-3, P1162
  • [4] Comparison of fixed speed and doubly-fed induction wind turbines during power system disturbances
    Holdsworth, L
    Wu, XG
    Ekanayake, JB
    Jenkins, N
    [J]. IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2003, 150 (03) : 343 - 352
  • [5] An improved fault ride-through strategy for doubly fed induction generator-based wind turbines
    Kasem, A. H.
    El-Saadany, E. F.
    El-Tamaly, H. H.
    Wahab, M. A. A.
    [J]. IET RENEWABLE POWER GENERATION, 2008, 2 (04) : 201 - 214
  • [6] Kundur P., 1993, Power System Stability And Control
  • [7] Doubly fed induction generator model for transient stability analysis
    Ledesma, P
    Usaola, J
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (02) : 388 - 397
  • [8] Dynamic behavior of the doubly fed induction generator during three-phase voltage dips
    Lopez, Jesus
    Sanchis, Pablo
    Roboam, Xavier
    Marroyo, Luis
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (03) : 709 - 717
  • [9] Does the use of stentless aortic valves in a subcoronary position prevent patient-prosthesis mismatch for small aortic annulus?
    Lopez, Stephane
    Mathieu, Patrick
    Pibarot, Philippe
    Mohammadi, Siamak
    Dagenais, Francois
    Voisine, Pierre
    Dumesnil, Jean
    Doyle, Daniel
    [J]. JOURNAL OF CARDIAC SURGERY, 2008, 23 (04) : 331 - 335
  • [10] Modal analysis of grid-connected doubly fed induction generators
    Mei, Francoise
    Pal, Bikash
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (03) : 728 - 736