An Experimental Investigation in the Performance of Water-Filled Silicon Microheat Pipe Arrays

被引:11
作者
Harris, D. K. [1 ]
Palkar, A. [2 ]
Wonacott, G. [3 ]
Dean, R. [4 ]
Simionescu, F. [5 ]
机构
[1] Auburn Univ, Dept Mech Engn, Auburn, AL 36849 USA
[2] Int Paint LLC, Houston, TX 77091 USA
[3] San Diego Composites Inc, San Diego, CA 92123 USA
[4] Auburn Univ, Dept Elect & Comp Engn, Auburn, AL 36849 USA
[5] URS Corp Washington Div, Birmingham, AL 35243 USA
关键词
microheat pipes; electronic cooling; thermal conductivity; thermal resistance; performance enhancement factor; HEAT PIPES; FABRICATION;
D O I
10.1115/1.4001745
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study details the fabrication and measurements of a water-filled 5 mm wide by 10 mm long silicon microheat pipe (MHP) array consisting of 22-100 mu m square channels. This study is unique in that many experimental results reported in open literature are for single channel microheat pipes. The number of channels in the array and the fluid charge used here were optimized under a separate study. A number of experiments were carried out on the specimen MHPs to determine their effective thermal conductivity and comparisons were made with previous results found in literature. The testing methodology was designed to remove systematic biases and the array thermal performance measurements are reported in terms of a silicon equivalence by identically measuring an uncharged empty silicon array as a baseline measurement. Two separate water-filled specimens were made, independently tested, and are reported to have thermal conductivities of 261 W/m K and 324 W/m K, representing a silicon equivalence of 1.8 and 2.2, respectively. All testing was performed in a horizontal orientation. [DOI: 10.1115/1.4001745]
引用
收藏
页码:0210051 / 0210058
页数:8
相关论文
共 21 条
[1]   STEADY-STATE MODELING AND TESTING OF A MICRO HEAT PIPE [J].
BABIN, BR ;
PETERSON, GP ;
WU, D .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1990, 112 (03) :595-601
[2]   Experimental results for low-temperature silicon micromachined micro heat pipe arrays using water and methanol as working fluids [J].
Badran, B ;
Gerner, FM ;
Ramadas, P ;
Henderson, T ;
Baker, KW .
EXPERIMENTAL HEAT TRANSFER, 1997, 10 (04) :253-272
[3]  
Cotter T.P., 1984, P 5 INT HEAT PIPE C, P328
[4]   Fabrication and test of radial grooved micro heat pipes [J].
Kang, SW ;
Tsai, SH ;
Chen, HC .
APPLIED THERMAL ENGINEERING, 2002, 22 (14) :1559-1568
[5]   Thermal characterization of flat silicon heat pipes [J].
Lai, A ;
Gillot, C ;
Ivanova, M ;
Avenas, Y ;
Louis, C ;
Schaeffer, C ;
Fournier, E .
TWENTIETH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, PROCEEDINGS 2004, 2004, :21-25
[6]   Fabrication and experimental investigation of silicon micro heat pipes for cooling electronics [J].
Le Berre, M ;
Launay, S ;
Sartre, V ;
Lallemand, M .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (03) :436-441
[7]   The performance of micro heat pipes measured by integrated sensors [J].
Le Berre, Martine ;
Pandraud, Guillaume ;
Morfouli, Panagiota ;
Lallemand, Monique .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2006, 16 (05) :1047-1050
[8]   Characterization of an integrated micro heat pipe [J].
Lee, M ;
Wong, M ;
Zohar, Y .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (01) :58-64
[9]  
MALLIK AK, 1995, ASME, V117, P75
[10]   Experimental study on the thermal performance of micro-heat pipe with cross-section of polygon [J].
Moon, SH ;
Hwang, G ;
Ko, SC ;
Kim, YT .
MICROELECTRONICS RELIABILITY, 2004, 44 (02) :315-321