Simultaneous spectrophotometric determination of phosphate and silicate by a stopped-flow sequential injection method

被引:14
作者
Mas-Torres, F [1 ]
Muñoz, A [1 ]
Estela, JM [1 ]
Cerdà, V [1 ]
机构
[1] Univ Balearic Isl, Dept Chem, Palma de Mallorca 07071, Spain
关键词
sequential injection; kinetic determination; phosphate; silicate; wastewater;
D O I
10.1080/03067310008032682
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sequential injection analysis method for the simultaneous spectrophotometric determination of phosphate and silicate has been developed. The method is based on the different reaction rates of the heteropolymolybdate formation reactions. Concentrations within the range 0.026-0.485 mmol P l(-1) and 0.125-2.848 mmol Si l(-1) have been determined at a frequency of 30 samples per hour. An R.S.D. of 2.1% was obtained for 0.162 mmol P l(-1) and of 1.1% for 1.424 mmol Si l(-1). The method was found to be suitable for the determination of phosphate and silicate in wastewater.
引用
收藏
页码:185 / 202
页数:18
相关论文
共 17 条
[1]   SANDWICH TECHNIQUES IN FLOW-INJECTION ANALYSIS .3. SIMULTANEOUS DETERMINATION OF CR(VI) IN 2 CONCENTRATION RANGES [J].
ALONSOCHAMARRO, J ;
BARTROLI, J ;
BARBER, R .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :219-223
[2]  
*AM PUBL HLTH ASS, 1989, APHA AWWA WPCF STAND
[3]   SIMULTANEOUS DETERMINATION OF TOTAL IRON AND CHROMIUM(VI) IN WASTE-WATER USING A FLOW-INJECTION SYSTEM BASED ON THE SANDWICH TECHNIQUE [J].
ARAUJO, AN ;
LIMA, JLFC ;
RANGEL, AOSS ;
ALONSO, J ;
BARTROLI, J ;
BARBER, R .
ANALYST, 1989, 114 (11) :1465-1468
[4]  
Chung S. C., 1992, Process Control and Quality, V3, P115
[5]   USE OF SEQUENTIAL INJECTION TECHNIQUE AND ROBOTICS FOR THE AUTOMATION OF RHFXIII FLUOROMETRIC ACTIVITY ASSAY - CASE-STUDY [J].
GUZMAN, M ;
COMPTON, BJ .
TALANTA, 1993, 40 (12) :1943-1950
[6]   MULTISTEP DETERMINATION OF ENZYME-ACTIVITY BY FLOW-INJECTION AND SEQUENTIAL INJECTION-ANALYSIS - ASSAY OF AMYLOGLUCOSIDASE [J].
HANSEN, EH ;
WILLUMSEN, B ;
WINTHER, SK ;
DRABOL, H .
TALANTA, 1994, 41 (11) :1881-1893
[7]  
Jacintho A.O., 1989, J FLOW INJECT ANAL, V6, P19
[8]   DETERMINATION OF ARSENATE, GERMANATE, PHOSPHATE AND SILICATE BY ION CHROMATOGRAPHY USING A POSTCOLUMN REACTION (MOLYBDENUM BLUE) DETECTOR [J].
JONES, P ;
STANLEY, R ;
BARNETT, N .
ANALYTICA CHIMICA ACTA, 1991, 249 (02) :539-544
[9]   SIMULTANEOUS REACTION-RATE DETERMINATIONS OF PHOSPHATE AND SILICATE [J].
KIRCHER, CC ;
CROUCH, SR .
ANALYTICAL CHEMISTRY, 1983, 55 (02) :248-253
[10]   FLUOROMETRIC DIFFERENTIAL-KINETIC DETERMINATION OF SILICATE AND PHOSPHATE IN WATERS BY FLOW-INJECTION ANALYSIS [J].
LINARES, P ;
DECASTRO, MDL ;
VALCARCEL, M .
TALANTA, 1986, 33 (11) :889-893