The role of cervical length in women with threatened preterm labor: is it a valid predictor at any gestational age?

被引:25
|
作者
Hiersch, Liran [1 ]
Yogev, Yariv
Domniz, Noam
Meizner, Israel
Bardin, Ron
Melamed, Nir
机构
[1] Helen Schneider Hosp Women, Rabin Med Ctr, Petah Tiqwa, Israel
关键词
cervical length; gestational age; preterm delivery; SINGLETON PREGNANCIES; ULTRASOUND ASSESSMENT; FETAL FIBRONECTIN; TRANSVAGINAL SCAN; BIRTH; RISK; SONOGRAPHY;
D O I
10.1016/j.ajog.2014.06.002
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: To determine whether the predictive accuracy of sonographic cervical length (CL) for preterm delivery (PTD) in women with threatened preterm labor (PTL) is related to gestational age (GA) at presentation. STUDY DESIGN: A retrospective cohort study of all women with singleton pregnancies who presented with PTL at less than 34 + 0 weeks and underwent sonographic measurement of CL in a tertiary medical center between 2007 and 2012. The predictive accuracy of CL for PTD was stratified by GA at presentation. RESULTS: Overall, 1077 women who presented with PTL have had sonographic measurement of CL and met the study inclusion criteria. Of those, 223 (20.7%) presented at 24 + 0-26 + 6 weeks (group 1), 274 (25.4%) at 27 + 0-29 + 6 weeks (group 2), 283 (26.3%) at 30+0-31+6 weeks (group 3), and 297 (27.6%) at 32+0-33+6 weeks (group 4). The overall performance CL as a predictive test for PTD was similar in the 4 GA groups, as reflected by the similar degree of correlation between CL with the examination to delivery interval (r = 0.27, r = 0.26, r = 0.28, and r = 0.29, respectively, P = .8), the similar area under the receiver-operator characteristic curve (0.641-0.690, 0.631-0.698, 0.643-0.654, and 0.678-0.698, respectively, P = .7), and a similar decrease in the risk of PTD of 5-10% for each additional millimeter of CL. The optimal cutoff of CL, however, was affected by GA at presentation, so that a higher cutoff of CL was needed to achieve a target negative predictive value for delivery within 14 days from presentation for women who presented later in pregnancy. The optimal thresholds to maximize the negative predictive value for delivery within 14 days were 36 mm, 32.5 mm, 24mm and 20.5 mm for women who presented at 32 + 0 to 33 + 6 weeks, 30 + 0 to 31 + 6 weeks, 27 + 0 to 29 + 6 weeks and 24 + 0 to 26 + 6, respectively. CONCLUSION: CL has modest predictive accuracy in women with threatened PTL, regardless of GA at presentation. However, the optimal cutoff of CL for the purpose of clinical decision making in women with PTL needs to be adjusted based on GA at presentation.
引用
收藏
页码:532.e1 / 532.e9
页数:9
相关论文
共 50 条
  • [21] Sonographic measurement of cervical length in twin pregnancies in threatened preterm labor
    Fuchs, I
    Tsoi, E
    Henrich, W
    Dudenhausen, JW
    Nicolaides, KH
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 23 (01) : 42 - 45
  • [22] Uterocervical Angle and Cervical Length as a Tool to Predict Preterm Birth in Threatened Preterm Labor
    Luechathananon, Sireethorn
    Songthamwat, Metha
    Chaiyarach, Sukanya
    INTERNATIONAL JOURNAL OF WOMENS HEALTH, 2021, 13 : 153 - 159
  • [23] Re: Transvaginal cervical length measurement for prediction of preterm birth in women with threatened preterm labor: a meta-analysis
    Wiegerinck, M. M.
    Vis, J. Y.
    Mol, B. W.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 35 (06) : 756 - 756
  • [24] Is measurement of cervical length an accurate predictive tool in women with a history of preterm delivery who present with threatened preterm labor?
    Melamed, N.
    Hiersch, L.
    Meizner, I.
    Bardin, R.
    Wiznitzer, A.
    Yogev, Y.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2014, 44 (06) : 661 - 668
  • [25] Cost-effectiveness analysis of cervical length measurement and fibronectin testing in women with threatened preterm labor
    van Baaren, Gert-Jan
    Vis, Jolande Y.
    Grobman, William A.
    Bossuyt, Patrick M.
    Opmeer, Brent C.
    Mol, Ben W.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2013, 209 (05) : 436.e1 - 436.e8
  • [26] Probability of prematurity by cervical dilatation and gestational age at preterm labor
    McWeeney, Dennis
    Miller, Richard
    Rhea, Debbie
    Stanziano, Gary
    OBSTETRICS AND GYNECOLOGY, 2006, 107 (04): : 31S - 31S
  • [27] Gestational age at cervical length measurement and preterm birth in twins
    Ehsanipoor, R. M.
    Haydon, M. L.
    Gaffaney, C. Lyons
    Jolley, J. A.
    Petersen, R.
    Lagrew, D. C.
    Wing, D. A.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 40 (01) : 81 - 86
  • [28] Gestational age at cervical length measurement and incidence of preterm birth
    Berghella, Vincenzo
    Roman, Amanda
    Daskalakis, Constantine
    Ness, Amen
    Baxter, Jason K.
    OBSTETRICS AND GYNECOLOGY, 2007, 110 (02): : 311 - 317
  • [29] Gestational age at cervical length measurement and preterm birth in twins
    Ehsanipoor, Robert
    Haydon, Michael
    Jolley, Jennifer
    Gaffaney, Cecilia Lyons
    Petersen, Rita
    Lagrew, David
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2009, 201 (06) : S169 - S169
  • [30] Sonographic measurement of cervical length and fetal fibronectin testing in threatened preterm labor
    Tsoi, E
    Akmal, S
    Geerts, L
    Jeffery, B
    Nicolaides, KH
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 27 (04) : 368 - 372