Portable detection of Staphylococcus aureus using personal glucose meter based on hybridization chain reaction strategy

被引:35
|
作者
Yang, Yuemeng [1 ]
Wu, Tingting [1 ]
Xu, Li-Ping [1 ]
Zhang, Xueji [1 ,2 ]
机构
[1] Univ Sci & Technol Beijing, Res Ctr Bioengn & Sensing Technol, Sch Chem & Biol Engn, Beijing Key Lab Bioengn & Sensing Technol, Beijing 100083, Peoples R China
[2] Shenzhen Univ, Hlth Sci Ctr, Sch Biomed Engn, Shenzhen 518060, Guangdong, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Personal glucose meter; Staphylococcus aureus; Hybridization chain reaction strategy; Portable; QUANTITATIVE DETECTION; METHICILLIN-RESISTANT; NANOPARTICLES; BIOSENSOR; APTASENSOR; READOUT; SENSOR;
D O I
10.1016/j.talanta.2021.122132
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Staphylococcus aureus is one of the most important food-borne bacterial pathogens and causes numerous illnesses. In this work, we report a sensitive and highly selective magnetic-aptamer biosensor based on a personal glucose meter (PGM) platform for the detection of Staphylococcus aureus. The aptamer for Staphylococcus aureus was immobilized on the magnetic bead by hybridization with the capture probe P. In the presence of Staphylococcus aureus, the aptamer was dissociated from the magnetic bead. Then the capture probe was exposed and could be hybridized with a biotinylated probe to trigger the DNA hybridization chain reaction (HCR), thus achieving the signal amplification. The concentration of streptavidin-labeled invertase can be read by PGM, thus can lead to the portable quantitative detection of Staphylococcus aureus. After optimization of various conditions, 5 mu M probe P, the MB-P reaction time for 36 h, the competition time for 60 min, 0.5 mu M H1 & H2, 0.5 M sucrose and the sucrose invertase catalytic reaction time for 50 min was chosen to achieve the better sensor performance. Under the optimal conditions, the fabricated sensor offers high sensitivity with the limit of detection about 2 CFU/mL. This sensitive PGM based sensor could successfully evaluate the Staphylococcus aureus concentration in real food samples, and the results are consistent with those obtained by using plate counting methods. Moreover, the PGM sensor can greatly reduce the required time compared to the plate counting methods. The fabricated sensor supplies an ideal solution for rapid portable detection of bacterial pathogens and holds its potential use in the quality control for agriculture and food enterprises, entry-exit inspection and quality testing for food.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Portable glucose meter-based label-free strategy for target DNA detection
    Kim, Hyo Yong
    Ahn, Jun Ki
    Park, Ki Soo
    Park, Hyun Gyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 310
  • [22] Cross primer exchange reaction-based amplification strategy for sensitive and convenient detection of HIV gene fragment using a personal glucose meter
    An, Yayun
    Kan, Ailing
    Ouyang, Aimei
    Zhang, Nan
    Jiang, Wei
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 393
  • [23] A portable personal glucose meter method for enzyme activity detection and inhibitory activity evaluation based on alkaline phosphatase-mediated reaction
    Hao Zhang
    Guo-Ying Chen
    Zheng-Ming Qian
    Wen-Jia Li
    Chun-Hong Li
    Yuan-Jia Hu
    Feng-Qing Yang
    Analytical and Bioanalytical Chemistry, 2021, 413 : 2457 - 2466
  • [24] A portable personal glucose meter method for enzyme activity detection and inhibitory activity evaluation based on alkaline phosphatase-mediated reaction
    Zhang, Hao
    Chen, Guo-Ying
    Qian, Zheng-Ming
    Li, Wen-Jia
    Li, Chun-Hong
    Hu, Yuan-Jia
    Yang, Feng-Qing
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (09) : 2457 - 2466
  • [25] A highly sensitive aptamer-immunoassay for vascular endothelial growth factor coupled with portable glucose meter and hybridization chain reaction
    Zhu, Xi
    Kou, Fangxia
    Xu, Huifeng
    Lin, Liping
    Yang, Guidi
    Lin, Zhenyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 253 : 660 - 665
  • [26] Nanomaterials for miRNA detection: the hybridization chain reaction strategy
    Mohan, Brij
    Kumar, Sandeep
    Kumar, Suresh
    Modi, Krunal
    Tyagi, Deependra
    Papukashvili, Dimitri
    Rcheulishvili, Nino
    Pombeiro, Armando J. L.
    SENSORS & DIAGNOSTICS, 2023, 2 (01): : 78 - 89
  • [27] A plasmonic colorimetric strategy for visual miRNA detection based on hybridization chain reaction
    Miao, Jie
    Wang, Jingsheng
    Guo, Jinyang
    Gao, Huiguang
    Han, Kun
    Jiang, Chengmin
    Miao, Peng
    SCIENTIFIC REPORTS, 2016, 6
  • [28] A plasmonic colorimetric strategy for visual miRNA detection based on hybridization chain reaction
    Jie Miao
    Jingsheng Wang
    Jinyang Guo
    Huiguang Gao
    Kun Han
    Chengmin Jiang
    Peng Miao
    Scientific Reports, 6
  • [29] Sensitive DNA detection using cascade amplification strategy based on conjugated polyelectrolytes and hybridization chain reaction
    Bao, Biqing
    Zhu, Jin
    Gong, Lina
    Chen, Jia
    Pan, Yanrui
    Wang, Lianhui
    RSC ADVANCES, 2017, 7 (06) : 3528 - 3533
  • [30] DNA Methyltransferase activity detection using the personal glucose meter
    Deng, Huimin
    Png, Si Ying
    Gao, Zhiqiang
    2015 9TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2015, : 28 - 33